Figure 13 – Location of LED Status Indicators inside the enclosure

LED STATUS INDICATORS Models 2995 contains two LED status indicators on the printed circuit board inside the enclosure. One LED is a green Power On indicator (PWR) that indicates the presence of the bus voltage and the operation of the main control logic power supply.

The other LED is a tricolor lamp (ST) that indicates a fault or abnormal condition. The information provided can be used to diagnose an installation problem, such as incorrect input voltage, overload condition and control circuit miswiring. It also provides a “normal” signal that informs the user that all control and microprocessor operating parameters are proper. The meaning of the different colors and flash frequencies are explained in Table 5.

TABLE 5 Interpretation of ST indicator LED

 

OPERATING

LED

LED FLASH

CORRECTIVE

CONDITION

COLOR

FREQUENCY

ACTION

Motor Running Normally

GREEN

SLOW FLASH*

N/A

Motor Running, but in

RED

STEADY, NO FLASH

LED will return to slow flashing green

Current Limit

 

 

if overload is removed before trip

Motor Stopped due to

RED

QUICK FLASH*

 

Current Limit Trip

 

 

 

Motor Stopped due to

RED

SLOW FLASH*

Motor will restart automatically if

Short Circuit

 

 

supply voltage is corrected

Motor Stopped due to

RED/YELLOW

QUICK FLASH*

Motor will restart automatically if

Control Under Voltage

 

 

supply voltage is corrected

Motor Stopped due to

RED/YELLOW

SLOW FLASH*

Motor will restart automatically if

Control Over Voltage

 

 

supply voltage is corrected

Normal Stop Condition

YELLOW

STEADY, NO FLASH

N/A

*FLASH DEFINITIONS:

Slow Flash = 1 second on, 1 second off Quick Flash = .25 second on, .25 second off

18

Image 18
Contents Phase AC Motor Speed Control Quick Reference Table of Contents Product Specifications Electrical RatingsImportant Safety Precautions Installation Examine before installationChoose a Suitable Location Mount ControlPreliminary Setup ConnectionPage Connect the Motor Electrical connections for ModelConnect to AC Power Connect AC Line CordClose and Seal the Enclosure Operation Check System Before StartingAdjust Trim Pots Optional Operate the InverterMIN Minimum Speed DEC/B Deceleration with 60 Hz or 120 Hz configuration CL Current Limit with I2t Shutdown Troubleshooting Abnormality Check Point CountermeasureOperating LED LED Flash Corrective Declaration of Conformity Type HPP-5337E4 AC Motor Speed Control, Model numberBodine Limited Warranty