Step 10 – Operate the Inverter

The PACESETTERTM “NEMA 4” series inverter is operated using the switches and speed dial on the front panel of the control. See Figure 10 for panel layout.

1)Turn the AC power ON using the toggle switch. The power lamp will illuminate.

2)Turn the direction switch to either the “forward” or “reverse” position.

3)Adjust speed by turning the knob of the speed potentiometer. Turning the pot fully CCW will produce the minimum output frequency, as set by the MIN trim pot inside the control (factory setting is 0 Hz). Turning the pot fully CW will produce the maximum output frequency, as set by the max speed jumper and the MAX trim pot inside the control (factory setting is 60 Hz).

4)To stop the motor momentarily, turn the direction switch to the “stop” position.

5)To change direction of the motor, turn the direction switch to the “stop” position, wait until the motor comes to a complete stop, and then turn the direction switch to either “forward” or “reverse” position.

6)To stop the motor for long periods of time, turn the AC power off using the toggle switch.

7)If the motor does not start promptly and run smoothly, refer to the “TROUBLESHOOTING” section.

Step 11 – Adjust Trim Pots (Optional)

These controls contain trim pots that have been factory adjusted for most applications. Some applications may require readjustment of the trim pots in order to tailor the control to exact requirements.

WARNING

Do not adjust trim pots with main power on if possible. If adjustments are made with power on, insulated adjustment tools must be used and safety glasses must be worn. High voltage exists in this control. Electrocution and/or fire hazard can result if caution is not exercised.

Figure 12 - Location of trim pots inside enclosure.

13

Image 13
Contents Phase AC Motor Speed Control Quick Reference Table of Contents Electrical Ratings Product SpecificationsImportant Safety Precautions Examine before installation InstallationMount Control Choose a Suitable LocationConnection Preliminary SetupPage Electrical connections for Model Connect the MotorConnect AC Line Cord Connect to AC PowerClose and Seal the Enclosure Check System Before Starting OperationOperate the Inverter Adjust Trim Pots OptionalMIN Minimum Speed DEC/B Deceleration with 60 Hz or 120 Hz configuration CL Current Limit with I2t Shutdown Abnormality Check Point Countermeasure TroubleshootingOperating LED LED Flash Corrective Type HPP-5337E4 AC Motor Speed Control, Model number Declaration of ConformityBodine Limited Warranty