United States Stove 4027 To Install the Heater, When Chimney Connector Exits Through the Ceiling

Page 13

Masonry, or other non-combustible products, attached directly to a combustible surface without an air space offer very little protection and cannot be considered a clearance reducer unless specified materials have been tested and listed for direct attachment to a combustible surface. The same applies to thin veneer brick and stone coverings. These materials provide adequate protection only when mounted on sheet metal with a 1 inch spacing to the wall.

A variety or prefabricated clearance reduction systems which have been tested and listed are available through heater dealers. Always look for a safety listing label on the product when selecting a clearance reduction system and make sure it is designed for solid fuel appliances. The manufactures of these systems provide specific installation instructions that must be followed exactly for a safe installation.

Should you choose to make your own clearance reduction system, contact your local fire department, fire marshal or building code inspector for specific requirements regarding home constructed clearance reduction systems and safe installation clearances to protect combustible materials.

CAUTION: READ ALL INSTRUCTIONS BEFORE INSTALLING THE HEATER.

TO INSTALL THE HEATER:

1.Make ready a suitable chimney. The chimney must complywith the requirements for Type 103-HT chimneys in the standard for chimneys, Factory Built, Residential Type and Building Appliances, UL 103.

2.Gather the necessary materials, tools, and supplies which will be needed to install the heater.

CAUTION: DO NOT USE MORE THAN ONE 90 DEGREE BEND (ELBOW) IN THE CHIMNEY CONNECTOR INSTALLATION. MORE THAN ONE 90 DEGREE BEND (ELBOW) IN THE CHIMNEY CONNECTOR COULD NEGA- TIVELY AFFECT CHIMNEY DRAFT.

3.I f the floor on which the heater is to be installed is wood or any other combustible material, place a floor protector (described earlier) on the floor where the heater will be installed.

CAUTION: THE FLOOR PROTECTOR MUST NOT BE PLACED ON CARPET. REMOVE CARPET FROM BENEATH THE FLOOR PROTECTOR.

4.Place the heater on the floor protector as shown in Figure 9.

5.Assemble the chimney connector stove pipe from the heater's flue collar to the chimney to determine if the chimney connector pipe will correctly extend from the heater's flue collar to the chimney. Any horizontal section of chimney connector stove pipe must slope upward at least 1/4-inch rise to the horizontal foot to help maintain a sufficient draft. Always install the chimney connector pipe with the crimped end toward the heater to prevent creosote or soot from leaking out of the chimney connector pipe joints. MAKE SURE CLEARANCES TO COMBUSTIBLES ARE MAITAINED AS SPECIFIED BY FIGURE

8IF A CLEARANCE REDUCTION SYSTEM IS NOT INSTALLED.

FIGURE 9 -

 

 

 

 

PLAN VIEWS SHOWING FLOOR PROTECTOR'S MINIMUM SIZE (DIMENSIONS IN INCHES)

 

 

 

2

2

 

 

 

 

 

FLOOR PROTECTOR

8

FLOOR PROTECTOR

 

8

 

 

 

 

16

 

 

16

8

8

8

 

8

WHEN CHIMNEY CONNECTOR EXITS

WHEN CHIMNEY CONNECTOR EXITS

 

THROUGH THE CEILING

THROUGH THE WALL

 

USSC

 

 

 

13

Image 13
Contents Owner’s Manual Safety Standards and Building Codes Safety PrecautionsMaterials Needed for Proper Installation Shaker Handle Assembly AssemblyFlue Collar Assembly Feed & Ash Door AssembliesRequirements Masonry ChimneyMasonry Chimney Requirements Chimney Height Requirements Masonry Chimney RequirementsOn Next Contiued on Next Part B Contin Metal Prefabricated Chimney Requirements Metal Prefabricated Chimney InstallationDetail Connection Detail Connection Minimum Clearances to Combustible Wall and Ceilings Heater InstallationMinimum Clearances to Combustible Materials in Inches When Chimney Connector Exits Through the Ceiling To Install the HeaterInstallation of Chimney Shield Burning Coal in your 4027/ASA7 Operating InstructionsIncreasing Heat From a Low Fire LoadingShaking Draft ControlsSafety ASA7 Model 4027 & ASA7 Parts List HOW to Order Repair Parts