ASSEMBLY

Before Assembly, inspect the heater thoroghly for missing parts or shipping damage. If any damage or missing parts are detected, report it to your heater dealer.

DO NOT INSTALL OR USE A DAMAGED OR INCOMPLETE HEATER

Shaker Handle Assembly:

1.First, remove the two(2) bolts from the left side of the unit where the shaker handle is to be mounted.

2.Next, spin the shaker plate (a) counteclockwise until it stops. Slide the shaker handle through the hole and on to the shaker grate. NOTE: Make sure that the shaker handle is in a 90 degree position and that the shaker grates are lying flat.

3.Rotate the shaker plate (a) clockwise until it touches the unit.Then give it another 1/2 turn or until the mounting holes coincide with the unit.

4.Attach to the unit with the bolts removed in step 1.

5.Screw one(1) of the spring handles, from the parts box, on to the shaker handle 3/4” -1” down in a clockwise motion.

Feed & Ash Door Assemblies:

Feed Door-

1.Screw one(1) of the spring handles, from the parts box, on to the Feed Door handle.

(A)

Ash Door-

1.Screw one(1) of the spring handles, from the parts box, on to the Feed Door handle.

2.Insert the 2-1/2” Carriage Bolt into the spin damper.

3.Then screw it in into the Ash Door as shown and At- tach the Lock Nut provided to the Carriage Bolt.

Flue Collar Assembly:

1.Mount the flue collar to the top of the unit using the (3) 5/16-18 x 1-1/2 bolts, (3) washers, and (3) weld tabs pro- vided in the parts box as shown

USSC

Side view of flue collar

mount to heater top

3

Image 3
Contents Owner’s Manual Safety Precautions Safety Standards and Building CodesMaterials Needed for Proper Installation Feed & Ash Door Assemblies AssemblyShaker Handle Assembly Flue Collar AssemblyRequirements Masonry ChimneyMasonry Chimney Requirements Chimney Height Requirements Masonry Chimney RequirementsOn Next Contiued on Next Part B Contin Metal Prefabricated Chimney Requirements Metal Prefabricated Chimney InstallationDetail Connection Detail Connection Heater Installation Minimum Clearances to Combustible Wall and CeilingsMinimum Clearances to Combustible Materials in Inches When Chimney Connector Exits Through the Ceiling To Install the HeaterInstallation of Chimney Shield Burning Coal in your 4027/ASA7 Operating InstructionsDraft Controls LoadingIncreasing Heat From a Low Fire ShakingSafety ASA7 Model 4027 & ASA7 Parts List HOW to Order Repair Parts