6.Place the crimped end of the first chimney pipe or elbow into the heater's flue collar and mark it through each of the holes in the heater's flue collar.
7.Remove the pipe or elbow from the flue collar and drill 1/8 - inch diameter holes at the points marked.
8.Apply the furnace to the inside surface of the heater's flue collar, reinstall the first pipe or elbow and fasten in place with No. 8 sheet metal screws. Apply additional furnace cement to the outside of the chimney connector flue collar joint if an airtight seal was achieved when the pipe or elbow was installed. Wipe all excess furnace cement from the joint with a rag or paper towel before the cement dries.
9.Assemble the remaining chimney connector pipes by apply furnace cement to the joints, drilling
10.Depending on the type chimney installed, connect the chimney connector to the chimney as shown in Figure 5 or as described by the chimney's manufacturer. Remember , we highly recommend use of UL
11.If the chimney to which the heater is connected is a metal prefabricated chimney that exits the home at a point 7 feet or less above ground level and runs up the outside of the residence, it will be necessary to construct a chimney shield to prevent someone from coming in contact with the outer surface of the hot chimney while the heater is in operation. The shield should be constructed from wire mesh or expanded metal (22 gauge minimum) to allow air circulation around the chimney. The openings in the shield should not be large enough to allow a
DANGER: IF ANY CLEARANCE TO UNPROTECTED COMBUSTIBLE WALL OR CEILING IS LESS THAN THOSE SPECIFIED BY FIGURE 8 AFTER HEATER INSTALLATION IS COMPLETED, A CLEARANCE REDUCTION SYSTEM MUST BE INSTALLED BEFORE THE FIRST FIRE IS BUILT IN THE HEATER; OTHERWISE, THE UNPROTECTED WALL OR CEILING COULD CATCH FIRE. REMEMBER, THERE ARE ALSO LIMITS AS TO HOW CLOSE THE HEATER CAN BE INSTALLED TO A COMBUSTIBLE SURFACE PROTECTED BY A CLEARANCE REDUCTION SYSTEM. RE- READ "MINIMUM CLEARANCES TO COMBUSTIBLE WALL AND CEILINGS" PRESENTED EARLIER IN THIS MANUAL.
FIGURE 10 -
INSTALLATION OF CHIMNEY SHIELD
7 FEET | CHIMNEY | |
(SHIELD NOT REQUIRED | ||
SHIELD | ||
BEYOND 7 FEET ABOVE | ||
| ||
GROUND LEVEL.) |
|
GROUND LEVEL
14 | USSC |