6.Place the crimped end of the first chimney pipe or elbow into the heater's flue collar and mark it through each of the holes in the heater's flue collar.

7.Remove the pipe or elbow from the flue collar and drill 1/8 - inch diameter holes at the points marked.

8.Apply the furnace to the inside surface of the heater's flue collar, reinstall the first pipe or elbow and fasten in place with No. 8 sheet metal screws. Apply additional furnace cement to the outside of the chimney connector flue collar joint if an airtight seal was achieved when the pipe or elbow was installed. Wipe all excess furnace cement from the joint with a rag or paper towel before the cement dries.

9.Assemble the remaining chimney connector pipes by apply furnace cement to the joints, drilling 1/8-inch diameter holes for and attaching each joint with three(3) No. 8 sheet metal screws. Wipe all excess furnace cement from the joints with a rag or a paper towel before the cement dries.

10.Depending on the type chimney installed, connect the chimney connector to the chimney as shown in Figure 5 or as described by the chimney's manufacturer. Remember , we highly recommend use of UL 103-HT chimney.

11.If the chimney to which the heater is connected is a metal prefabricated chimney that exits the home at a point 7 feet or less above ground level and runs up the outside of the residence, it will be necessary to construct a chimney shield to prevent someone from coming in contact with the outer surface of the hot chimney while the heater is in operation. The shield should be constructed from wire mesh or expanded metal (22 gauge minimum) to allow air circulation around the chimney. The openings in the shield should not be large enough to allow a 1/2-inch diameter rod to pass through. The shield should have sufficient rigidity to provide the required protection and be permanently installed as shown in Figure 10.

DANGER: IF ANY CLEARANCE TO UNPROTECTED COMBUSTIBLE WALL OR CEILING IS LESS THAN THOSE SPECIFIED BY FIGURE 8 AFTER HEATER INSTALLATION IS COMPLETED, A CLEARANCE REDUCTION SYSTEM MUST BE INSTALLED BEFORE THE FIRST FIRE IS BUILT IN THE HEATER; OTHERWISE, THE UNPROTECTED WALL OR CEILING COULD CATCH FIRE. REMEMBER, THERE ARE ALSO LIMITS AS TO HOW CLOSE THE HEATER CAN BE INSTALLED TO A COMBUSTIBLE SURFACE PROTECTED BY A CLEARANCE REDUCTION SYSTEM. RE- READ "MINIMUM CLEARANCES TO COMBUSTIBLE WALL AND CEILINGS" PRESENTED EARLIER IN THIS MANUAL.

FIGURE 10 -

INSTALLATION OF CHIMNEY SHIELD

7 FEET

CHIMNEY

(SHIELD NOT REQUIRED

SHIELD

BEYOND 7 FEET ABOVE

 

GROUND LEVEL.)

 

GROUND LEVEL

14

USSC

Image 14
Contents Owner’s Manual Materials Needed for Proper Installation Safety PrecautionsSafety Standards and Building Codes Flue Collar Assembly AssemblyShaker Handle Assembly Feed & Ash Door AssembliesMasonry Chimney RequirementsMasonry Chimney Requirements Masonry Chimney Requirements Chimney Height RequirementsOn Next Contiued on Next Part B Contin Metal Prefabricated Chimney Installation Metal Prefabricated Chimney RequirementsDetail Connection Detail Connection Minimum Clearances to Combustible Materials in Inches Heater InstallationMinimum Clearances to Combustible Wall and Ceilings To Install the Heater When Chimney Connector Exits Through the CeilingInstallation of Chimney Shield Operating Instructions Burning Coal in your 4027/ASA7Shaking LoadingIncreasing Heat From a Low Fire Draft ControlsSafety ASA7 Model 4027 & ASA7 Parts List HOW to Order Repair Parts