TROUBLE SHOOTING TIPS FOR WARM AIR FURNACE
List of Problems | Possible Cause | Solutions |
1. Smoking when feed door is open. | a) Insufficient draft. | a) Open spin dampers. |
| b) Clogged chimney or chimney | b) Clean chimney. |
| connector. |
|
| c) Down draft in chimney. | c) Add raincap to chimney. |
|
|
|
2. Furnace does not heat. | a) Wood not seasoned and dry. | a) Allow wood to season in a dry, well |
|
| ventilated area for six months. |
| b) Blower control set too low. | b) Set blower control to higher |
|
| temperature (See Page 19). |
| c) Insufficient flue draft. | c) Set flue draft (See Page 9). |
|
|
|
3. Blower does not run. | a) Improperly wired. | a) Wire unit properly. |
| b) Bad blower control. | b) Replace blower control. |
| c) Bad relay. | c) Replace relay. |
| d) Bad blower motor. | d) Replace blower. |
|
|
|
4. No air from registers - fan running. | a) Registers are closed. | a) Open registers. |
| b) Duct work improperly installed. | b) Correct duct work installations. |
| c) Improper wiring between central | c) Wire unit properly. |
| furnace and Model 22AF. |
|
|
|
|
5. Air from registers is not hot. | a) Blower control set too low. | a) Adjust blower control to higher |
|
| setting (See Page 19). |
| b) Bad blower control. | b) Replace blower control. |
|
|
|
6. Blower runs too long. | Blower control cut off set too low. | Set blower control cut off to higher |
|
| setting (See Page 19) |
|
|
|
7. Blower does not run long enough. | a) Blower control cut off set too high. | a) Set blower control cut off to lower |
|
| setting (See Page 19). |
| b) Bad blower motor. | b) Replace blower. |
|
|
|
8. Smoke and/or odor from registers | Oil from furnace and duct work. | The metal used in construction of the |
when furnace is used for first time. |
| furnace and duct work has a light |
|
| coating of oil. This should disappear |
|
| after a short period of time. Once this |
|
| |
|
| reoccur. |
|
|
|
9. Creosote | a) Burning green wood (not seasoned | a) Burn only seasoned wood. |
| or dry). |
|
| b) Thermostat setting too low for type | b) Set thermostat higher to attain |
| fuel. | higher flue temperatures. This will aid |
|
| in preventing |
|
|
|
10. Flame spillage when feed door is | a) Insufficient draft. | a) Open stack damper. |
open. | b) Smothering fire when adding fresh | b) Add fuel so as not to smother fire. |
| fuel. |
|
|
|
|
28 | •DRAWINGS FOR ILLUSTRATION PURPOSES ONLY• |