United States Stove B9945L manual Cleaning / Servicing, Match Lighting Instructions, Pilot Flame

Page 14

OPERATING INSTRUCTIONS

WARNING

Wait30secondsbeforereadjustingtheheaterwhenthecontrolhasbeenturned downtoalowersetting.

MATCH LIGHTING INSTRUCTIONS

If the pilot will not light using the piezo ignitor, you can light the pilot with a match. First, locate the pilot. The pilot is located between the burner tube on the right end (facing the unit), inside the firebox. To light pilot with a match, move the gas control (knob B, pg. 13) to the pilot position and hold down. Light match and place near pilot. Once pilot is lit, continue to hold the knob for about ten seconds. Then follow steps 9 thru 13 on page 13.

CHECKING FLAME APPEARANCE

Flames from the pilot and burner should be visually checked when the heater is installed. In addition, a periodic checkoftheflamesshouldbemade.

PILOT FLAME

The pilot flame should always be present when the heaterisinoperation andshould just touch the topof the thermocouple tip (FIGURE 9).

If the pilot flame does not touch the thermocouple, then the main burner is unlikely to function reliably (FIGURE 10).

FIGURE 9. Pilot Flame

FIGURE 10. Incorrect Shape of Pilot Flame

CLEANING / SERVICING

Annual inspection and cleaning by your dealer or qualified service technician is recommended to prevent malfunction and/or sooting.

WARNING Turn off heater and allow to cool before cleaning.

Remove front screen, (see page 11). Carefully lift screen from locating stubs and set aside during cleaning. Refer to instructions on page 11 for installation of screen. Do not operate the unit with the screen removed.

Remove logs, handling carefully by holding gently at each end. Gloves are recommended to prevent skin irritation from ceramic. If the skin becomes irritated, wash gently with soap and water. Refer to manual for

correct log placement.

14

 

Image 14
Contents United States Stove Company ~WHAT to do if YOU Smell GASTable of Contents Important Safety Information Product Features FeaturesSpecifications ContentsCodes Items Required for InstallationItems Required for Installation Installation Minimum ClearancesMantel Clearances GAS Connection Gas ConnectionGAS Pressure Check Rear View of 9945 Vent-Free Gas HeaterRemoving Front Screen LOG AssemblyProper Installation Sequence LOG PositioningOperating Instructions For Your Safety Read Before LightingFor Your Safety What to do if YOU Smell GASLighting Instructions Turn OFF GAS to ApplianceChecking Flame Appearance Cleaning / ServicingMatch Lighting Instructions Pilot FlameFlame Appearance FlamesHeater Assembly Replacement Parts Parts List for Heater Assembly KEY Description QTYBurner & LOG Assembly Parts List for Generator and LOG Assembly Troubleshooting Observed Problem Possible Cause RemedyObservedproblem Possiblecause Remedy Optional Kits for Wiring Diagram for Generator Assembly Optional Kits FortheWiring with the WTK60 Wall Thermostat KIT Standard Wiring from FactoryWiring of the RCK60 Remote Control KIT Wiring with the WSK60 Wall Switch KIT Control ValvePage Limited Warranty Policy Howto Order Repair Parts or Options United States Stove Company