United States Stove B9945L manual Installation, Minimum Clearances

Page 7

INSTALLATION

Thefollowingformulacanbeusedtodeterminethemaximum heater ratingperthedefinition of unconfinedspace:

BTU/HR = (L1+L2) Ft x (W) Ft x (H) Ft x 1000

50

Considertwoconnectingroomswithanopenareabetween,

 

 

with the following dimensions:(See Fig. 2, Example)

 

 

L1=15-1/2 Ft., L2=12 Ft., W=12 ft., H=8Ft

 

H (8')

50

 

L2 (12')

 

=52800 BTU/HR

 

 

 

 

L1 (15-1/2')

W (12')

 

 

If there were a door between the two rooms the calculation

 

 

would be based only on the room with the heater. BTU/HR=(15-1/2) x (12) x (8) x 1000

50

FIGURE 2.

=29760 BTU/HR

WARNING WARNING WARNING

When installing the appliance directly on carpeting,tile or other combustible material,otherthanwoodflooring,theappliancemustbeinstalledonametalor woodpanelextendingthefullwidthanddepthoftheappliance.

Iftheareainwhichtheheatermaybeoperatedissmallerthanthatdefinedasan unconfined space or if the building is of unusually tight construction,provide adequatecombustionandventilationairbyoneofthemethodsdescribedinthe NationalFuelGasCode,ANSIZ223.1,Section5.3,orapplicablelocalcodes.

Ensure the minimum clearances shown in FIGURE 3 are maintained for accessibility for purposes of servicing and proper operation.Left and right clearancesaredeterminedwhenfacingthefrontoftheheater.

36"

8"

8"

42"

4"

Maintaintheseclearancesto ensure adequate space around air opening for properoperation.

Minimumclearancestocombustibles:

Topofheater

36"

Sidesofheater

8"

Frontofheater

42"

Rearofheater

4"

FIGURE 3. Minimum Clearances

7

Image 7
Contents ~WHAT to do if YOU Smell GAS United States Stove CompanyTable of Contents Important Safety Information Features Product FeaturesContents SpecificationsItems Required for Installation Items Required for InstallationCodes Minimum Clearances InstallationMantel Clearances Gas Connection GAS ConnectionRear View of 9945 Vent-Free Gas Heater GAS Pressure CheckLOG Positioning LOG AssemblyProper Installation Sequence Removing Front ScreenWhat to do if YOU Smell GAS For Your Safety Read Before LightingFor Your Safety Operating InstructionsTurn OFF GAS to Appliance Lighting InstructionsPilot Flame Cleaning / ServicingMatch Lighting Instructions Checking Flame AppearanceFlames Flame AppearanceHeater Assembly Replacement Parts KEY Description QTY Parts List for Heater AssemblyBurner & LOG Assembly Parts List for Generator and LOG Assembly Observed Problem Possible Cause Remedy TroubleshootingObservedproblem Possiblecause Remedy Optional Kits for Optional Kits Forthe Wiring Diagram for Generator AssemblyWiring of the RCK60 Remote Control KIT Standard Wiring from FactoryWiring with the WTK60 Wall Thermostat KIT Control Valve Wiring with the WSK60 Wall Switch KITPage Limited Warranty Policy United States Stove Company Howto Order Repair Parts or Options