Baumatic BGG64W manual Gas adjustment Conversion to LPG, Butane, Propane

Page 25

Gas adjustment (Conversion to LPG)

All work must be carried out by a GASSAFE registered engineer.

IMPORTANT: Always isolate the hob from the electricity supply before changing the injectors and/or adjusting the minimum flow of the burners.

o Remove the pan-stands, burners and flame spreaders (A).

oUnscrew the injector (B) and replace it with the stipulated injector for the new gas supply (see table on next page).

GENERAL INJECTORS TABLE

Kind of gas

Nozzle

Burners

Power (in watts)

 

mm/100

 

Max.

Min.

Natural

95/55/95

Wok

3800

1700

 

129

Rapid

3000

1500

 

97

Semi-rapid

1750

900

 

76

Auxiliary

1000

500

L.P.G.

65/41/65

Wok

3800

1300

Butane

87

Rapid

3000

700

Propane

65

Semi-rapid

1750

400

 

51

Auxiliary

1000

350

oReassemble all the burners carefully; in particular you should make sure that the flame spreader is correctly placed on the burner.

oIMPORTANT: The minimum flow adjustment process must be completed before the appliance is next used.

25

Image 25 Contents
BGG30 / BGG32 / BGG60 / BGG64 / BGG70 / BGG74 Gas hobs BGG30 / BGG32 Cm Burner gas hob BGG60 / BGG64 Contents Environmental note General Information Important safety informationGeneral Safety Child SafetyDuring use Installation CleaningDeclaration of conformity  Flame failure safety device on each burner SpecificationsProduct specifications BGG60 BGG60 / BGG64 Product dimensions Aperture dimensionsProduct specifications BGG64 Product specifications BGG70 / BGG74 Product dimensions Aperture dimensionsSupply Connection Rated VoltageMax Rated Inputs Mains Supply LeadBGG60 Gas hob surface layoutBGG64 Switching the hob on Using the gas hobAutomatic ignition with flame failure safety device Before first useMinimum Maximum Diametre Energy saving tipsCleaning the hob top CleaningCleaning the hob burners After each useMaintaining the cast iron pan stands InstallationPositioning Unpacking the appliance Installing the applianceBGG30 / BGG32 BGG60 / BGG64 BGG70 / BGG74 All models Important information Gas connectionVentilation requirements Important On completion carry out a gas soundness test Gas Safety Installation and Use RegulationsButane Gas adjustment Conversion to LPGPropane Minimum flow adjustment for hob gas taps Gas tap maintenance Electrical connection Switch the appliance off at your mains supplyReplacing the mains supply cable Do not Attempt to Repair the Appliance Yourself My appliance isn’t working correctlyBaumatic Consumables United Kingdom