Baumatic BGG64W manual Minimum flow adjustment for hob gas taps

Page 26

Minimum flow adjustment for hob gas taps.

All work must be carried out by a GASSAFE registered engineer.

IMPORTANT: Always isolate the hob from the electricity supply before changing the injectors and/or adjusting the minimum flow of the burners.

o Switch the burner on and set the knob at the minimum position.

o Remove the knob from the tap and place a small bladed screwdriver in the centre of the tap shaft.

oUnscrew the adjusting screw, in order to increase the gas flow or tighten the adjusting screw to decrease the gas flow.

oThe correct adjustment is obtained when the flame has a length of about 3 – 4 mm.

oFor butane/propane gas, the adjusting screw must be tightly screwed in.

oRefit the control knob.

oMake sure that the flame does not go out by quickly turning from maximum flow to minimum flow. If it does then remove the control knob and make further adjustments to the gas flow, testing it again once the adjustment has been made.

oRepeat this process for each one of the gas taps.

26

Image 26 Contents
BGG30 / BGG32 / BGG60 / BGG64 / BGG70 / BGG74 Gas hobs BGG30 / BGG32 Cm Burner gas hob BGG60 / BGG64 Contents Environmental note Important safety information General InformationDuring use Child SafetyGeneral Safety Declaration of conformity CleaningInstallation Specifications  Flame failure safety device on each burnerProduct specifications BGG64 BGG60 / BGG64 Product dimensions Aperture dimensionsProduct specifications BGG60 BGG70 / BGG74 Product dimensions Aperture dimensions Product specificationsMax Rated Inputs Rated VoltageSupply Connection Mains Supply LeadGas hob surface layout BGG60BGG64 Automatic ignition with flame failure safety device Using the gas hobSwitching the hob on Before first useEnergy saving tips Minimum Maximum DiametreCleaning the hob burners CleaningCleaning the hob top After each useInstallation Maintaining the cast iron pan standsPositioning Installing the appliance Unpacking the applianceBGG30 / BGG32 BGG60 / BGG64 BGG70 / BGG74 All models Gas connection Important informationVentilation requirements Gas Safety Installation and Use Regulations Important On completion carry out a gas soundness testPropane Gas adjustment Conversion to LPGButane Minimum flow adjustment for hob gas taps Gas tap maintenance Replacing the mains supply cable Switch the appliance off at your mains supplyElectrical connection My appliance isn’t working correctly Do not Attempt to Repair the Appliance YourselfBaumatic Consumables United Kingdom