Gas adjustment (Conversion to LPG for the hob top)
All work must be carried out by a GASSAFE registered engineer.
IMPORTANT: Always isolate the cooker from the electricity supply before changing the injectors and/or adjusting the minimum flow of the burners.
o Remove the
oUnscrew the injector and replace it with the stipulated injector for the new gas supply (see table below).
Burner | Types | Pressure | Injector | Gas |
| Power | ||
| of gas | (mbar) | Marking | consumption | (kW) | |||
|
|
| (1/100 | g/h |
| l/h | Max. | Min. |
|
|
| mm) |
|
|
|
|
|
Auxiliary | Natural | 20 | 72 | - |
| 95 | 1.00 | 0.48 |
| (G20) |
|
|
|
|
|
|
|
| Butane | 30 | 50 | 73 |
| - |
|
|
| (G30) |
|
|
|
|
|
|
|
| Propane | 37 | 50 | 71 |
| - |
|
|
| (G31) |
|
|
|
|
|
|
|
Semi- | Natural | 20 | 97 | - |
| 167 | 1.75 | 0.60 |
rapid | (G20) |
|
|
|
|
|
|
|
32