oIMPORTANT: They must be screwed clockwise into position and not just slotted into the holes on each corner.
Gas connection
This appliance must be installed by a competent person in accordance with the current versions of the following UK (United Kingdom) or ROI (Republic of Ireland) Regulations and Safety Standards or their European Norm Replacements.
Important information
oThis cooker is supplied to run on natural gas only and cannot be used on any other type of gas without modification.
oConversion for use on LPG and other gases must only be undertaken by a qualified person. For information on the use of other gases, please contact the Baumatic Technical Department.
oThe cooker must be installed by a qualified person, in accordance with the current edition of the Gas Safety (Installation and Use) (Amendment) Regulations and the relevant building/I.E.E. Regulations.
oFailure to install the appliance correctly could invalidate Baumatic’s guarantee and lead to prosecution under the regulations quoted above.
oIn the UK, CORGI registered installers are authorised to undertake the installation and service work, in compliance with the above regulations.
Ventilation requirements
oThe room containing the cooker should have an air supply in accordance with the current edition of BS 5440: Part 2:
oThe room must have opening windows or equivalent; some rooms may also require a permanent vent.
oIf the room has a volume between 5 and 10m³, it will require an air vent of 50cm² (effective area). Unless it has a door which opens directly to the outside.
oIf the room has a volume of less than 5m³, it will require an air vent of 100cm² (effective area).
28