Lennox International Inc 51M32 Cooling Control, Adjusting Temperature Setpoint, Cooling Demand

Page 3

Heating Demand

ROOM 72

FAN

AUTO

88 SYSTEM

HEAT

Figure 6

When the actual temperature rises above the temperature setpoint, the flame icon will disappear. This indicates that the heating demand has been satisfied and that the heating equipment has been turned off.

NOTE − The heating equipment is activated for at least 3 minutes if no buttons are pressed during the demand inter- val.

Cooling Control

The COOL button is located behind the small door on the right-hand side of the thermostat. See figure 3.

Enabling and Disabling Cool Mode

Use the COOL button to enable or disable cool mode as necessary. If the thermostat is in off mode, cool mode is en- abled when the COOL button is pressed. This is indicated by COOL in the SYSTEM box.

If the thermostat is in cool mode, cool mode is disabled when the COOL button is pressed. This is indicated by OFF in the SYSTEM box.

Cooling Demand

The thermostat must be in cool mode in order to properly control the cooling equipment. When in cool mode, if the room temperature is higher than the temperature setpoint, a cooling demand is detected by the thermostat.

The thermostat will then activate the cooling equipment to satisfy the demand. Cooling operation is indicated by a snowflake icon in the SYSTEM box as shown in figure 7. When the actual temperature drops below the temperature setpoint, the snowflake icon will disappear. This indicates that the cooling demand has been satisfied and that the cooling equipment has been turned off.

Cooling Demand

ROOM 79

FAN

AUTO

SYSTEM

COOL

Figure 7

NOTE − The cooling equipment is activated for at least 4 minutes if no buttons are pressed during the demand inter- val. Cooling equipment operation is locked out for 5 min- utes after a demand has been satisfied. If another cooling demand occurs during this 5−minute interval, the snowflake icon will flash; however, the cooling equipment will not run until the 5−minute delay has elapsed.

Adjusting Temperature Setpoint

The temperature setpoint represents the desired tempera- ture of the space around the thermostat. The default tem- perature setpoint is 70°F. To adjust the setpoint, press the UP or DOWN arrow keys to the right of the display screen.

The existing setpoint will be displayed just below the actual room temperature as shown in figure 8. Use the UP or DOWN arrow keys to adjust the setpoint up or down. The setpoint will increase by 1°F each time the UP key is pressed. The setpoint will decrease by 1°F each time the DOWN key is pressed.

Setpoint Display and Adjustment

ROOM 69

FAN

AUTO

SETPOINT 64 SYSTEM

HEAT

Figure 8

After the desired setpoint is reached, the HOME screen will reappear after about 8 seconds.

Page 3

Image 3
Contents General Table of ContentsInitial Thermostat Power-up MeritR Series ThermostatDisplay − Home Screen Heat Mode EnabledHeat Mode Disabled Heating ControlCooling Control Adjusting Temperature SetpointEnabling and Disabling Cool Mode Setpoint Display and AdjustmentFilter Reminder Fan ControlTechnical Specifications Service IndicatorThermostat Reset Default Thermostat SettingsThermostat Output Table Controls 51M33 Emergency Heat Mode Enabled Additional Thermostat Buttons Normal Heat ModeEmergency Heat Mode Normal Heat Mode EnabledCooling Control Fan Control Balance Point Setting Service Indicator Flashing RoomBalance Point Backup Heat Source Selection 51M33 Terminal DesignationsBalance Point Thermostat Output Table Gas Heat Backup Dual Fuel − Outdoor Sensor Attached Electric Heat Backup − No Outdoor SensorGas Heat Backup Dual Fuel − No Outdoor Sensor Electric Heat Backup − Outdoor Sensor Attached