Lennox International Inc LENNOX Elite Series XP13 Units HEAT PUMPS, 06/11 50672801 XP13 Series

Page 31

Thermostat Operation

See the thermostat homeowner manual for instructions on how to operate your thermostat.

Heat Pump Operation

Your new Lennox heat pump has several characteristics that you should be aware of:

SHeat pumps satisfy heating demand by delivering large amounts of warm air into the living space. This is quite different from gas- or oil-fired furnaces or an electric furnace which deliver lower volumes of considerably hotter air to heat the space.

SDo not be alarmed if you notice frost on the outdoor coil in the winter months. Frost develops on the outdoor

coil during the heating cycle when temperatures are below 45°F (7°C). The heat pump control activates a defrost cycle lasting 5 to 15 minutes at preset intervals to clear the outdoor coil of the frost.

SDuring the defrost cycle, you may notice steam rising from the outdoor unit. This is a normal occurrence. The thermostat may engage auxiliary heat during the defrost cycle to satisfy a heating demand; however, the unit will return to normal operation at the conclusion of the defrost cycle.

Extended Power Outage

The heat pump is equipped with a compressor crankcase heater which protects the compressor from refrigerant slugging during cold weather operation.

If power to your unit has been interrupted for several hours or more, set the room thermostat selector to the EMERGENCY HEAT setting to obtain temporary heat without the risk of serious damage to the heat pump.

In EMERGENCY HEAT mode, all heating demand is satisfied by auxiliary heat; heat pump operation is locked out. After a six-hour compressor crankcase warm-up period, the thermostat can be switched to the HEAT setting and normal heat pump operation may resume.

Preservice Check

If your system fails to operate, check the following before calling for service:

SVerify room thermostat settings are correct.

SVerify that all electrical disconnect switches are ON.

SCheck for any blown fuses or tripped circuit breakers.

SVerify unit access panels are in place.

SVerify air filter is clean.

SIf service is needed, locate and write down the unit model number and have it handy before calling.

Accessories

For update−to−date information, see any of the following publications:

SLennox XP13 Engineering Handbook

SLennox Product Catalog

SLennox Price Book

Page 31

XP13 SERIES

Image 31
Contents Shipping and Packing List Table of ContentsGeneral TOP View Unit Dimensions − Inches mmModel Number Identification 13 −036 − 230 −08 Side ViewTypical Unit Parts Arrangement PLUMBING, Switches Sensor ComponentsControl Panel Caps and Fasteners Torque Requirements Operating Gauge Set and Service ValvesOperating Service Valves Using Manifold Gauge SETOperating Ball−Type Service Valve Operating Angle−Type Service ValveReinstall Stem Cap Method Method 2 Limitations Recovering Refrigerant from Existing System1DISCONNECT Power 3RECOVERING RefrigerantNew Outdoor Unit Placement Placement, Slab Mounting and Stabilizing Unit Detail a Outside Unit PlacementLouvered Panel Installation Removing and Installing PanelsLouvered Panel Removal Adding Polyol Ester OIL Requirements NEW or Replacement Line SET InstallationUsing Existing Line SET Line Set RequirementsRefrigerant Line SET Alling Horizontal Runs Refrigerant Line SET From Vertical to HorizontalBrazing Connections 2CAP and Core Removal 1CUT and DeburPreparation for Next Step Wrap Service ValvesFlow Nitrogen 6BRAZE Line SET3FLUSHING Line SET 2CONNECT Gauges and Equipment for Flushing ProcedureEqualizer Line Installation Installing New Indoor Metering DeviceIndoor Expansion Valve Installation Sensing Bulb InstallationConnect Gauge SET Leak Test Line Set and Indoor CoilTest for Leaks 2EVACUATE the System Evacuating Line Set and Indoor Coil24VAC Transformer Size Circuit and Install Disconnect2INSTALL Thermostat ElectricalTypical Unit Wiring Diagram Unit START−UP Unit Start−UpConnect Manifold Gauge SET and WEIGH−IN Charge Leak CHECK, Repair and EvacuateConnections for Optimizing System Charge Calculating System Charge for Outdoor Unit Void of Charge Using HFC−410A Weigh In MethodCFM = Optimizing ProcedureAdjusting Indoor Airflow Optimizing System Refrigerant ChargeRefrigerant SATº LIQºSCº If subcooling value isNormal Operating Pressures − Liquid +10 and Vapor +5 Psig HFC−410A Temperature F − Pressure Psig Defrost System System OperationDefrost Control CMC1 OFF Indoor Coil MaintenanceDealer Indoor UnitXP13 Series Sequence of Operation Thermostat Start−Up and Performance ChecklistInstaller City Job Name Job no Date Job Location City

LENNOX Elite Series XP13 Units HEAT PUMPS, 06/11 50672801 specifications

Lennox International Inc., a leading name in the HVAC (heating, ventilation, and air conditioning) industry, has a reputation for delivering high-quality and energy-efficient systems. One of the standout products in their lineup is the Lennox Elite Series XP13 heat pump, model number 50672801. This heat pump is designed to provide exceptional comfort throughout the year while offering efficiency and reliability that homeowners can depend on.

The Lennox Elite Series XP13 heat pump features a compact design that makes it suitable for various outdoor spaces. One of its main characteristics is its efficiency, boasting a SEER (Seasonal Energy Efficiency Ratio) rating of up to 16 and an HSPF (Heating Seasonal Performance Factor) of up to 9. This means that the XP13 can help reduce energy bills, making it an eco-friendly choice for homeowners looking to minimize their carbon footprint.

This heat pump utilizes advanced technology to ensure optimal performance. The XP13 is equipped with a scroll compressor, which operates quietly and efficiently compared to traditional compressors. This feature ensures a more reliable and consistent temperature control, which translates to enhanced comfort levels in the home. Moreover, the XP13 is designed with a sound-dampening system that reduces operational noise, making it one of the quieter options in the market.

Another key aspect of the XP13 heat pump is its innovative use of advanced coil technology. The unit's coils are made from high-grade aluminum, which promotes superior heat exchange and improves overall efficiency. In addition, the XP13 is designed with a built-in filter drier that helps remove moisture and contaminants from the refrigerant, protecting the system from potential damage and enhancing its lifespan.

The XP13 model is compatible with the iComfort S30 smart thermostat, allowing users to control their home’s temperature remotely. This smart technology provides energy-saving options and real-time updates, ensuring that homeowners can optimize their HVAC systems for both comfort and efficiency.

Overall, the Lennox Elite Series XP13 heat pump, model 50672801, exemplifies a commitment to delivering high-performance heating and cooling solutions. With its energy-efficient design, advanced technologies, and features aimed at enhancing user comfort and convenience, the XP13 remains a top choice among homeowners looking for a reliable and effective heat pump system.