Lennox International Inc LENNOX Elite Series XP13 Units HEAT PUMPS Unit Start−Up, Unit START−UP

Page 21

Figure 15. Typical Factory Wiring

Unit Start−Up

have consulted with the power company and the voltage condition has been corrected.

IMPORTANT

If unit is equipped with a crankcase heater, it should be energized 24 hours before unit start−up to prevent compressor damage as a result of slugging.

UNIT START−UP

1.Rotate fan to check for binding.

2.Inspect all factory− and field−installed wiring for loose connections.

3.Verify that the manifold gauge set is connected as illustrated in figure 17. Use a temperature sensor positioned near the liquid line service port as illustrated in figure 17 which will be required later when using the subcooling method for optimizing the system refrigerant charge.

4.Replace the stem caps and tighten to the value listed in table 1.

5.Check voltage supply at the disconnect switch. The voltage must be within the range listed on the unit’s nameplate. If not, do not start the equipment until you

6.Open both the liquid and vapor line service valves to release the refrigerant charge contained in outdoor unit into the system.

7.Use figure 16 to determine next step in system preparation.

OPEN BOTH VAPOR AND LIQUID SERVICE

 

VALVE STEMS TO RELEASE

REFRIGERANT FROM OUTDOOR UNIT TO

 

SYSTEM.

NO

PRESENT

YES

 

 

GO TO SERVICE AND WEIGH

 

IN REFRIGERANT CHARGE

GO TO OPTIMIZING SYSTEM

FOR OUTDOOR UNITS

REFRIGERANT CHARGE ON

DELIVERED VOID OF CHARGE

PAGE 24.

ON PAGE 22.

 

Figure 16. Outdoor Unit Factory Charge

Page 21

XP13 SERIES

Image 21
Contents Table of Contents Shipping and Packing ListGeneral Model Number Identification 13 −036 − 230 −08 Unit Dimensions − Inches mmSide View TOP ViewPLUMBING, Switches Sensor Components Typical Unit Parts ArrangementControl Panel Operating Service Valves Operating Gauge Set and Service ValvesUsing Manifold Gauge SET Caps and Fasteners Torque RequirementsOperating Angle−Type Service Valve Operating Ball−Type Service ValveReinstall Stem Cap 1DISCONNECT Power Recovering Refrigerant from Existing System3RECOVERING Refrigerant Method Method 2 LimitationsNew Outdoor Unit Placement Placement, Slab Mounting and Stabilizing Unit Detail a Outside Unit PlacementRemoving and Installing Panels Louvered Panel InstallationLouvered Panel Removal Using Existing Line SET NEW or Replacement Line SET InstallationLine Set Requirements Adding Polyol Ester OIL RequirementsRefrigerant Line SET Alling Horizontal Runs Refrigerant Line SET From Vertical to HorizontalBrazing Connections 2CAP and Core Removal 1CUT and DeburFlow Nitrogen Wrap Service Valves6BRAZE Line SET Preparation for Next Step3FLUSHING Line SET 2CONNECT Gauges and Equipment for Flushing ProcedureIndoor Expansion Valve Installation Installing New Indoor Metering DeviceSensing Bulb Installation Equalizer Line InstallationLeak Test Line Set and Indoor Coil Connect Gauge SETTest for Leaks 2EVACUATE the System Evacuating Line Set and Indoor Coil2INSTALL Thermostat Size Circuit and Install DisconnectElectrical 24VAC TransformerTypical Unit Wiring Diagram Unit START−UP Unit Start−UpLeak CHECK, Repair and Evacuate Connect Manifold Gauge SET and WEIGH−IN ChargeConnections for Optimizing System Charge Calculating System Charge for Outdoor Unit Void of Charge Using HFC−410A Weigh In MethodAdjusting Indoor Airflow Optimizing ProcedureOptimizing System Refrigerant Charge CFM =SCº SATº LIQºIf subcooling value is RefrigerantNormal Operating Pressures − Liquid +10 and Vapor +5 Psig HFC−410A Temperature F − Pressure Psig System Operation Defrost SystemDefrost Control CMC1 OFF Dealer MaintenanceIndoor Unit Indoor CoilXP13 Series Installer City Start−Up and Performance ChecklistJob Name Job no Date Job Location City Sequence of Operation Thermostat

LENNOX Elite Series XP13 Units HEAT PUMPS, 06/11 50672801 specifications

Lennox International Inc., a leading name in the HVAC (heating, ventilation, and air conditioning) industry, has a reputation for delivering high-quality and energy-efficient systems. One of the standout products in their lineup is the Lennox Elite Series XP13 heat pump, model number 50672801. This heat pump is designed to provide exceptional comfort throughout the year while offering efficiency and reliability that homeowners can depend on.

The Lennox Elite Series XP13 heat pump features a compact design that makes it suitable for various outdoor spaces. One of its main characteristics is its efficiency, boasting a SEER (Seasonal Energy Efficiency Ratio) rating of up to 16 and an HSPF (Heating Seasonal Performance Factor) of up to 9. This means that the XP13 can help reduce energy bills, making it an eco-friendly choice for homeowners looking to minimize their carbon footprint.

This heat pump utilizes advanced technology to ensure optimal performance. The XP13 is equipped with a scroll compressor, which operates quietly and efficiently compared to traditional compressors. This feature ensures a more reliable and consistent temperature control, which translates to enhanced comfort levels in the home. Moreover, the XP13 is designed with a sound-dampening system that reduces operational noise, making it one of the quieter options in the market.

Another key aspect of the XP13 heat pump is its innovative use of advanced coil technology. The unit's coils are made from high-grade aluminum, which promotes superior heat exchange and improves overall efficiency. In addition, the XP13 is designed with a built-in filter drier that helps remove moisture and contaminants from the refrigerant, protecting the system from potential damage and enhancing its lifespan.

The XP13 model is compatible with the iComfort S30 smart thermostat, allowing users to control their home’s temperature remotely. This smart technology provides energy-saving options and real-time updates, ensuring that homeowners can optimize their HVAC systems for both comfort and efficiency.

Overall, the Lennox Elite Series XP13 heat pump, model 50672801, exemplifies a commitment to delivering high-performance heating and cooling solutions. With its energy-efficient design, advanced technologies, and features aimed at enhancing user comfort and convenience, the XP13 remains a top choice among homeowners looking for a reliable and effective heat pump system.