Raypak 514-824 manual Automaticchlorinatorsandchemicalfeed- Ers, Unithermgovernoroperation

Page 13

AUTOMATICCHLORINATORSANDCHEMICALFEED- ERS

All chemicals must be introduced and completely diluted into the pool or spa water before being circulated through the heater. Do not place chlorine tablets or bromine sticks in the skimmer. High chemical concen- trations will result when the pump is not running (i.e. overnight).

Chlorinatorsmustfeeddownstreamoftheheaterand have an anti-siphoning device to prevent chemical back- up into the heater when the pump is shut off.

NOTE: High chemical concentrates from feeders and chlorinators that are out of adjustment will cause very rapid corrosion to the heat exchanger in the heaters. Such damage is not covered under the warranty.

UNITHERMGOVERNOROPERATION

The patented Unitherm Governor is a thermostatic mixing valve specifically designed to maintain constant heater internal temperature between 105°F to 115°F despite continually changing flow rated from the filter and changing pool temperatures. This narrow range is needed to prevent damaging condensation on the burn- ers which will occur if the heater runs for any length of time below 100°F. It is also needed to inhibit scale formation in the tubes by maintaining temperatures well below accelerated scaling temperatures.

EXTERNAL AUXILIARY BYPASS VALVE (Where Required)

An auxiliary bypass valve should be used when flow rates exceed 115 GPM (usually a high performance pump size larger than two HP will exceed this flow rate). This valve is required to complement the function of the automatic bypass valve, particularly when starting the heater in winter or early spring when the spa or pool temperature is down below 55°F. It also serves to eliminate needless pressure drop through the heat and accompanying reduction in the flow rate to the spa jets, etcetera.

FROM

TO

HEATER

HEATER

To set bypass: with clean filter, adjustment is made by feeling the inlet and outlet pipes at the heater. Outlet pipesshouldbeslightlywarmerthaninletandcomfortable to the touch. If pipe is hot, close bypass; if cold open bypass.

The heater is also equipped with a manual bypass built into the header. This is in addition to the automatic bypass valve. This may be used with flow rates up to 120 GPM and adjusted as below.

NOTE: Sooting or liming caused by improper bypass adjustment voids the warranty

BYPASSVALVE

INLET/OUTLET

HEADER

Fig. # 8223.0

MANUAL BYPASS ADJUSTMENT

OPEN POSITION

CLOSED POSITION

Fig. # 8222.0

PRESSURE RELIEF VALVE INSTALLATION

To conform to local building codes, it may be necessary to install a pressure relief valve. A 3/4” pressure relief valve having a capacity equal to BTU/HR outputofthemodeltobeinstalledisrecommendedforthis appliance.

A 3/4” NPT connection is provided in the inlet/outlet header for installation of a pressure relief valve. The valve shall be installed in a vertical position.

PRESSURE RELIEF VALVE

INLET/OUTLET HEADER

TO POOL

FROM

 

POOL

Fig. # 8150.0

AUXILIARY BYPASS VALVE ADJUSTMENTINLET

OUTLET

Fig.#8223.0

13

Image 13
Contents What to do if YOU Smell GAS Installation Operating Instructions CommercialWaterchemistry Contents For Your Safety Read Before Operating START-UP Procedures Before START-UPBurners WaterTo Turn OFF GAS to Appliance Operating InstructionsWater Pressure Switch Maintenance and Care ProceduresAfter START-UP Visual InspectionPool & SPA Water Chemistry Basic Tips if Heater will not FireCalifornia Proposition 65 Warning Important NoticeClearances Base InstallationStep #2 Indoor HeaterVenting Connections Vent PipingAnsi Z Gaspressureregulator GAS Supply ConnectionsPlumbing for Water Connections Location Pipe Sizing for GAS ConnectionsFlow Rates Model Pipe Size MIN. GPM MAX. GPM CompanionflangeconnectionsAuxiliary Bypass Valve Adjustmentinlet Pressure Relief Valve InstallationAUTOMATICCHLORINATORSANDCHEMICALFEED- ERS UnithermgovernoroperationS8600 Ignition Control Electrical WiringPage 151965 152141 152142 Typical Comfortable SPA Temperature Range CONTROLS/ADJUSTMENTS/REPLACEMENTSKnobstopadjustment Servicing InsructionsPressure Switch Adjustment Pressure SwitchPressure Switch Adjustment Range Pilot SafetyRaypak Tube Cleaning KIT UNITHERMGOVERNORU.G.REPLACEMENT DesootingprocedureCombustionchamberremoval Important Notice Liming Electrical Troubleshooting Honeywell S8600Highvoltage Raypak, Inc Agoura Road Westlake Village, CA Replacement Parts ListThis page is empty Pilot ASSEMBLY- Electronic Ignition Page Page
Related manuals
Manual 32 pages 49.67 Kb

514-824 specifications

The Raypak 514-824 is a leading model in the realm of heating solutions, specifically designed for outdoor residential and commercial applications. Known for its efficiency and durability, the Raypak 514-824 has gained popularity among users looking for reliable heating systems.

One of the standout features of the Raypak 514-824 is its advanced design that incorporates high-quality materials ensuring longevity. This model is constructed with a robust heat exchanger, typically made of copper or bronze, which promotes better thermal conductivity while resisting corrosion. This ensures that the unit maintains a high performance level even after prolonged use, making it an excellent choice for areas with varying weather conditions.

The technological aspects of the Raypak 514-824 are also impressive. It is equipped with an intuitive digital control system that allows for precise temperature adjustments. Users can easily set their desired temperature, which is maintained automatically, providing comfort with minimal manual control. The digital display is user-friendly, making it simple to monitor system performance and adjust settings as needed.

Efficiency is a critical characteristic of the Raypak 514-824. With a focus on energy-saving capabilities, this heater exceeds industry standards, often achieving efficiency ratings that minimize energy consumption. This not only results in cost savings on utility bills but also contributes to environmental sustainability, making it a more responsible choice for heating needs.

Safety features are paramount in the design of the Raypak 514-824. It includes various protections such as high-limit switches and pressure regulators that help prevent overheating and maintain optimal operating conditions. These safety measures ensure that the unit operates reliably and minimizes risks associated with traditional heating systems.

Furthermore, installation versatility sets the Raypak 514-824 apart. It is designed for straightforward installation, suitable for various setups whether it's integrated with a swimming pool or spa heating system. This adaptability makes it an ideal selection for anyone looking to enhance their outdoor space with effective heating solutions.

In summary, the Raypak 514-824 is a high-performing, efficient, and versatile heating model that combines modern technology with significant safety features. Its emphasis on user-friendly operation and long-lasting materials makes it a top contender in the heating market, catering to both residential and commercial applications. The Raypak 514-824 exemplifies a commitment to quality, efficiency, and reliability.