OPERATING INSTRUCTIONS

1.STOP! Read the safety information above.

2.Set the thermostat on the lowest setting.

3.Turn off all electric power to the appliance.

4.Remove heater door panel.

5.This appliance is equipped with an ignition device which automatically light the pilot. Do not try to light the pilot by hand.

6.For Models 514-724 with Honeywell Gas Valve. Push in gas control knob slightly and turn clockwise

to “OFF”. Knob cannot be turned to “OFF” unless knob is pushed in slightly. Do not Force.

GAS CONTROL KNOB

SHOWN IN “ON”

POSITION

GAS INLET

Fig. #8219.0

For Models 514-724 with Robertshaw Gas Valve.

Turn Gas control knob clockwise to “OFF”.

GAS CONTROL

KNOB SHOWN

IN “ON” POSITIONS

GAS INLET

Fig. # 8080.0

For Models 824

Turn main gas shut-off and pilot shut-off valves counter

clockwise to “OFF”.

PILOT SHUT-OFF

TO PILOT

 

VALVE CONTROL

MAIN GAS SHUT-OFF

SHOWN IN THE

VALVE SHOWN IN

“ON” POSITION

THE “ON” POSITION

GAS

 

INLET

 

 

Fig. # 8220.0

7.Wait fire (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow "B" in the safety information above on this label. If you don't smell gas, go to the next step

8.For Models 514-724

Turn gas control knob counter clockwise to “On”

For Model 824

Turn main gas shut-off and pilot shut-off valves

clockwise to on.

9. Replace heater door panel.

10.Turn on all electric power to the appliance.

11.Set thermostat to desired setting.

12.If the appliance will not operate, follow the instruc- tions “To Turn Off Gas to Appliance” and call your service technician or gas supplier.

TO TURN OFF GAS TO APPLIANCE

1.Set the thermostat to the lowest setting.

2.Turn off all the electric power to the appliance if service is to be performed.

3.Remove heater door panel.

4.For Models 514-724

Push in gas control knob slightly and turn clock-

wise to “OFF”.

For Models 824

Turn main gas shut-off and pilot shut-off valves

counter clockwise to “OFF”.

5. Replace heater door panel.

5

Image 5
Contents What to do if YOU Smell GAS Installation Operating Instructions Commercial Waterchemistry Contents For Your Safety Read Before Operating START-UP Procedures Before START-UPBurners WaterTo Turn OFF GAS to Appliance Operating InstructionsWater Pressure Switch Maintenance and Care ProceduresAfter START-UP Visual InspectionPool & SPA Water Chemistry Basic Tips if Heater will not FireCalifornia Proposition 65 Warning Important NoticeClearances Base InstallationStep #2 Indoor HeaterVenting Connections Vent PipingAnsi Z Gaspressureregulator GAS Supply ConnectionsPlumbing for Water Connections Location Pipe Sizing for GAS ConnectionsFlow Rates Model Pipe Size MIN. GPM MAX. GPM CompanionflangeconnectionsAuxiliary Bypass Valve Adjustmentinlet Pressure Relief Valve InstallationAUTOMATICCHLORINATORSANDCHEMICALFEED- ERS UnithermgovernoroperationS8600 Ignition Control Electrical WiringPage 151965 152141 152142 Typical Comfortable SPA Temperature Range CONTROLS/ADJUSTMENTS/REPLACEMENTSKnobstopadjustment Servicing InsructionsPressure Switch Adjustment Pressure SwitchPressure Switch Adjustment Range Pilot SafetyRaypak Tube Cleaning KIT Combustionchamberremoval DesootingprocedureUNITHERMGOVERNORU.G.REPLACEMENT Important Notice Liming Highvoltage Troubleshooting Honeywell S8600Electrical Raypak, Inc Agoura Road Westlake Village, CA Replacement Parts ListThis page is empty Pilot ASSEMBLY- Electronic Ignition Page Page