Page 8

Installation must be in accordance with local codes, or, in the absence of local codes, with the latest edition of the National Fuel Gas Code, ANSI Z223.1 and National Electrical Code, ANSI/NFPA 70.

BASE INSTALLATION

Heater must be mounted on a level base, such as cement slab, cement blocks or other non-combustible surface. An optional non-combustible surface. An optional non-combustible base is available for all models. An alternative method for providing a base for combus- tible floors is illustrated. Heater must not be installed on carpeting.

CLEARANCES

ALL HEATERS

For clearances from combustible surfaces, see the chart below

CLEARANCE FROM COMBUSTIBLE

CONSTRUCTION

INDOORINSTALLATIONS:

Top* (Drafthood) - 36" Back - 10"

Front - Alcove Right Side 6"

Vent - 6"Left Side (Water Side) 6"

OUTDOORINSTALLATION:

Top* (Stackless Top) - Unobstructed

Back - 10" Side - 6"

12"

Minimum

4" Minimum

12"

Minimum

Sheet Metal

24 Gauge

Fig. # 8148.0

*Clearance from top of vent terminal.

*For servicing, provide at lease 24" in front of the heater for burner tray removal, and at least 18" on water connection side of the heater to inspect and delime the heat exchanger.

Hollow Concrete Cinder Block, Align Holes And Leave

Ends Open. Alternative Method For Providing A Non-

Combustible Base.

OUTDOOR HEATERS

These heaters are design certified for outdoor installation, when equipped with the approved tops designated for outdoor use.

Heaters must not be installed under an overhang of less than three (3) feet from the top of the heater. Three

(3)sides must be open in the area under the overhang. Roof water drainage must be diverted away from the heaters installed under overhangs with the use of gutters.

WARNING: The heater shall not be located in an area where water sprinklers, or other devices, may cause water to spray through the cabinet louvers and into the heater. This could cause heavy internal rusting or damage some electrical components, and this would void the warranty.

The point from where the flue products exit the heater must be a minimum of four (4) feet below, four (4) feet horizontally from or one (1) foot above any door, window or gravity inlet to a building. The top surface of the heater shall be at least three (3) feet above any forced air inlet, or intake ducts located within ten (10) feet horizontally.

4 foot

 

Minimum

 

 

4 foot

 

Minimum

4 foot

 

Minimum

 

3 foot

 

Minimum

 

10 foot

1 foot

Minimum

Minimum

 

Forced Air Inlet

Fig. # 8245.0

 

 

8

HIGH WIND CONDITIONS

(OUTDOORUNITSONLY)

In areas where high winds are fre- quent, it may be necessary to locate the heater a minimum of 3' from high vertical walls, or install a wind break so the heater is not in direct wind current.

Image 8
Contents Installation Operating Instructions Commercial What to do if YOU Smell GASWaterchemistry Contents START-UP Procedures Before START-UP For Your Safety Read Before OperatingBurners WaterOperating Instructions To Turn OFF GAS to ApplianceMaintenance and Care Procedures Water Pressure SwitchAfter START-UP Visual InspectionBasic Tips if Heater will not Fire Pool & SPA Water ChemistryCalifornia Proposition 65 Warning Important NoticeBase Installation ClearancesIndoor Heater Step #2Venting Connections Vent PipingAnsi Z GAS Supply Connections GaspressureregulatorPipe Sizing for GAS Connections Plumbing for Water Connections LocationFlow Rates Model Pipe Size MIN. GPM MAX. GPM CompanionflangeconnectionsPressure Relief Valve Installation Auxiliary Bypass Valve AdjustmentinletAUTOMATICCHLORINATORSANDCHEMICALFEED- ERS UnithermgovernoroperationElectrical Wiring S8600 Ignition ControlPage 151965 152141 152142 CONTROLS/ADJUSTMENTS/REPLACEMENTS Typical Comfortable SPA Temperature RangeKnobstopadjustment Servicing InsructionsPressure Switch Pressure Switch AdjustmentPressure Switch Adjustment Range Pilot SafetyRaypak Tube Cleaning KIT Combustionchamberremoval DesootingprocedureUNITHERMGOVERNORU.G.REPLACEMENT Important Notice Liming Highvoltage Troubleshooting Honeywell S8600Electrical Replacement Parts List Raypak, Inc Agoura Road Westlake Village, CAThis page is empty Pilot ASSEMBLY- Electronic Ignition Page Page
Related manuals
Manual 32 pages 49.67 Kb

514-824 specifications

The Raypak 514-824 is a leading model in the realm of heating solutions, specifically designed for outdoor residential and commercial applications. Known for its efficiency and durability, the Raypak 514-824 has gained popularity among users looking for reliable heating systems.

One of the standout features of the Raypak 514-824 is its advanced design that incorporates high-quality materials ensuring longevity. This model is constructed with a robust heat exchanger, typically made of copper or bronze, which promotes better thermal conductivity while resisting corrosion. This ensures that the unit maintains a high performance level even after prolonged use, making it an excellent choice for areas with varying weather conditions.

The technological aspects of the Raypak 514-824 are also impressive. It is equipped with an intuitive digital control system that allows for precise temperature adjustments. Users can easily set their desired temperature, which is maintained automatically, providing comfort with minimal manual control. The digital display is user-friendly, making it simple to monitor system performance and adjust settings as needed.

Efficiency is a critical characteristic of the Raypak 514-824. With a focus on energy-saving capabilities, this heater exceeds industry standards, often achieving efficiency ratings that minimize energy consumption. This not only results in cost savings on utility bills but also contributes to environmental sustainability, making it a more responsible choice for heating needs.

Safety features are paramount in the design of the Raypak 514-824. It includes various protections such as high-limit switches and pressure regulators that help prevent overheating and maintain optimal operating conditions. These safety measures ensure that the unit operates reliably and minimizes risks associated with traditional heating systems.

Furthermore, installation versatility sets the Raypak 514-824 apart. It is designed for straightforward installation, suitable for various setups whether it's integrated with a swimming pool or spa heating system. This adaptability makes it an ideal selection for anyone looking to enhance their outdoor space with effective heating solutions.

In summary, the Raypak 514-824 is a high-performing, efficient, and versatile heating model that combines modern technology with significant safety features. Its emphasis on user-friendly operation and long-lasting materials makes it a top contender in the heating market, catering to both residential and commercial applications. The Raypak 514-824 exemplifies a commitment to quality, efficiency, and reliability.