Raypak 514-824 START-UP Procedures Before START-UP, For Your Safety Read Before Operating, Water

Page 4

PART ONE - OWNER’S OPERATING INSTRUCTIONS

FOR YOUR SAFETY - READ BEFORE OPERATING

WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT, CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.

SECTION 1/START-UP PROCEDURES

BEFORE START-UP

BURNERS

Clean main burners and air louvers of dust, lint and debris. Keep heater area clear and free from com- bustibles, flammable liquids and chemicals. Do not obstruct the flow of combustion and ventilating air.

WATER

First thing, insure that system is filled with water and have pump operating. Water must be flowing through the heater during operation.

CAUTION: Propane gas is heavier than air and will settle on the ground. Since propane can accumulate in confined areas, extra care should be exercised when lighting propane heater.

OPERATING INSTRUCTIONS AND SHUT-OFF PROCEDURES

AUTOMATICALLY LIGHTED PILOTS

ELECTRONIC IGNITIONS SYSTEMS

A.This appliance is equipped with an ignition device which automatically lights the pilot. Do not try to light the pilot by hand.

B.BEFORE OPERATING, smell all around the appli- ance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS:

Do not try to light any appliance.

Do not touch any electric switch; do not use any telephone in your building.

Immediately call your gas supplier from a neigh- bor's telephone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, do not try to repair it; call a qualified service technician. Force or attempted repair may result in fire or explosion.

D.Do not use this appliance if any part has been underwater. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been underwater.

4

Image 4
Contents Installation Operating Instructions Commercial What to do if YOU Smell GASWaterchemistry Contents START-UP Procedures Before START-UP For Your Safety Read Before OperatingBurners WaterOperating Instructions To Turn OFF GAS to ApplianceMaintenance and Care Procedures Water Pressure SwitchAfter START-UP Visual InspectionBasic Tips if Heater will not Fire Pool & SPA Water ChemistryCalifornia Proposition 65 Warning Important NoticeBase Installation ClearancesIndoor Heater Step #2Venting Connections Vent PipingAnsi Z GAS Supply Connections GaspressureregulatorPipe Sizing for GAS Connections Plumbing for Water Connections LocationFlow Rates Model Pipe Size MIN. GPM MAX. GPM CompanionflangeconnectionsPressure Relief Valve Installation Auxiliary Bypass Valve AdjustmentinletAUTOMATICCHLORINATORSANDCHEMICALFEED- ERS UnithermgovernoroperationElectrical Wiring S8600 Ignition ControlPage 151965 152141 152142 CONTROLS/ADJUSTMENTS/REPLACEMENTS Typical Comfortable SPA Temperature RangeKnobstopadjustment Servicing InsructionsPressure Switch Pressure Switch AdjustmentPressure Switch Adjustment Range Pilot SafetyRaypak Tube Cleaning KIT UNITHERMGOVERNORU.G.REPLACEMENT DesootingprocedureCombustionchamberremoval Important Notice Liming Electrical Troubleshooting Honeywell S8600Highvoltage Replacement Parts List Raypak, Inc Agoura Road Westlake Village, CAThis page is empty Pilot ASSEMBLY- Electronic Ignition Page Page
Related manuals
Manual 32 pages 49.67 Kb

514-824 specifications

The Raypak 514-824 is a leading model in the realm of heating solutions, specifically designed for outdoor residential and commercial applications. Known for its efficiency and durability, the Raypak 514-824 has gained popularity among users looking for reliable heating systems.

One of the standout features of the Raypak 514-824 is its advanced design that incorporates high-quality materials ensuring longevity. This model is constructed with a robust heat exchanger, typically made of copper or bronze, which promotes better thermal conductivity while resisting corrosion. This ensures that the unit maintains a high performance level even after prolonged use, making it an excellent choice for areas with varying weather conditions.

The technological aspects of the Raypak 514-824 are also impressive. It is equipped with an intuitive digital control system that allows for precise temperature adjustments. Users can easily set their desired temperature, which is maintained automatically, providing comfort with minimal manual control. The digital display is user-friendly, making it simple to monitor system performance and adjust settings as needed.

Efficiency is a critical characteristic of the Raypak 514-824. With a focus on energy-saving capabilities, this heater exceeds industry standards, often achieving efficiency ratings that minimize energy consumption. This not only results in cost savings on utility bills but also contributes to environmental sustainability, making it a more responsible choice for heating needs.

Safety features are paramount in the design of the Raypak 514-824. It includes various protections such as high-limit switches and pressure regulators that help prevent overheating and maintain optimal operating conditions. These safety measures ensure that the unit operates reliably and minimizes risks associated with traditional heating systems.

Furthermore, installation versatility sets the Raypak 514-824 apart. It is designed for straightforward installation, suitable for various setups whether it's integrated with a swimming pool or spa heating system. This adaptability makes it an ideal selection for anyone looking to enhance their outdoor space with effective heating solutions.

In summary, the Raypak 514-824 is a high-performing, efficient, and versatile heating model that combines modern technology with significant safety features. Its emphasis on user-friendly operation and long-lasting materials makes it a top contender in the heating market, catering to both residential and commercial applications. The Raypak 514-824 exemplifies a commitment to quality, efficiency, and reliability.