Raypak Y-200 manual Sensor Resistance at Various Temperatures, Temperature F Resistance K Ohms

Page 37

 

 

Sensor Resistance at Various

 

Temperatures

 

If a sensor error is suspected, perform the following:

 

1. Examine the wiring, ensuring continuity from con-

 

troller to sensor(s).

 

2. Using a multimeter, measure resistance of sen-

 

sor(s) and compare the value with the Table M

 

below.

 

3. If all okay, replace main control board.

 

Temperature (°F)

Resistance (K Ohms)

-20

1666.3

-10

1193.1

0

863.6

10

631.7

20

466.7

30

348.0

40

262.0

50

199.0

60

153.6

70

119.4

80

93.5

90

73.8

100

58.6

110

46.9

120

37.7

130

30.5

140

24.9

150

20.5

160

16.9

170

14.1

180

11.7

190

9.9

200

8.3

210

7.0

220

6.0

Table M: Sensor Resistance at Various Temperatures

37

Image 37
Contents Series Is a registered trademark of Underwriters Laboratories Inc Contents Concept of Operation Please RegisterOptions Controller ConfigurationsElectrical Installation Mechanical InstallationCheck Your Power Source Power to the Controller Controller Field WiringFor Single-Stage ON/OFF Boilers For Multiple-Stage BoilersWiring Diagram Slave Cable Installation from System Control Module Air Temperature Sensor InstallationHydronic Heating Applications Water Temperature Sensor InstallationCheck Power Power TestDomestic Hot Water Supply Applications Installation Verification Procedure Control Screens Screen Description Factory DefaultInlet / Outlet Manual OverrideCircuit Board Layout Circuit Board LayoutProgram Mode Normal ModeKeypad Initial Screen Control Screen Displays & ProgrammingPrimary Parameters M MControl Band Proportional Only Control BandN T R O L F S E T OffsetF S E F S E T F UReset Ratio Reset ParameterHoliday T T I N GRadiation System to Outdoor TemperatureSystem Status Advanced Programming FeatureMessage Meaning Outdoor Cut-Off Temperature Water TemperatureOutdoor Cut-Off Deadband T O F FSystem Monitor System TemperaturesSystem Pump no Screen O R S B S a a aBoiler/Stage on Delay Auxiliary DelayBoiler Turn-On Delay Stage Turn-On DelayBoiler Turn-Off Delay Boiler/Stage Off DelayStage Turn-Off Delay Proportional Integral Derivative PIDFor Manual Only Lead Change TimeFor Auto Only A DSetup PasswordTo enter the password S S W O R DWater Temperature Limits Set PasswordTo change the default password AAA to a new password System TestStage/Sensor Connections for Y-200 Master/Slave Systems Master UnitSlave Unit Factory DefaultsLonWorks Optional Modem Password User DefaultsAlarm Call ID Alarm Call TelephoneAlarm Call Retry Alarm Call EventsPID Interval Master Unit with SlavesA V E S N E C T E D T W O R KX X X X X X X XA V E S C O N N E C T E D V E X X X X X XMaster/Slave Diagram Temperature F Resistance K Ohms Sensor Resistance at Various TemperaturesIllustrated Parts List Limited Warranty
Related manuals
Manual 7 pages 24.2 Kb

Y-200 specifications

The Raypak Y-200 is a sophisticated and robust swimming pool heater that is designed for efficiency, durability, and optimal performance. Ideal for both residential and commercial pools, the Y-200 is equipped with advanced technology to ensure a seamless heating experience, catering to pool owners who prioritize quality and reliability.

One of the main features of the Raypak Y-200 is its impressive heating capacity. With a powerful heater that can efficiently raise the temperature of water in larger pools, users can enjoy comfortable swimming conditions year-round. The heater is designed to be easy to install and maintain, allowing for hassle-free integration into existing pool systems.

The Y-200 utilizes innovative digital controls, which give users precise measurement and adjustment capabilities. This includes a user-friendly display that provides real-time feedback on temperature settings and operational status. The digital interface makes it simple to program the heater according to individual preferences, ensuring that water is always at the desired temperature.

In terms of energy efficiency, the Raypak Y-200 boasts advanced technology that reduces energy consumption while maximizing heat output. The heater is designed with a reliable and robust heat exchanger that utilizes copper fin technology, providing excellent thermal conductivity and corrosion resistance. This ensures longevity and reduces the need for frequent maintenance.

Additionally, the Y-200 incorporates environmentally friendly technologies, including low-NOx emissions, aligning with modern standards for sustainability. This feature not only minimizes the environmental impact but also assists in meeting local regulations concerning emissions.

Durability is a hallmark of the Raypak Y-200. Constructed with high-quality materials designed to withstand the rigors of outdoor conditions, it provides users with peace of mind knowing that their investment is protected. The heater is also equipped with a weather-resistant cabinet, ensuring reliable operation regardless of climate.

In conclusion, the Raypak Y-200 stands out in the market due to its powerful heating capacity, advanced digital controls, energy-efficient technologies, and durable construction. It is an excellent choice for pool owners seeking a dependable and efficient heating solution to enhance their swimming experience. With its combination of high performance and user-friendly features, the Y-200 represents a valuable addition to any pool setting.