Raypak B6000 manual Boiler Monitor Communications Jumper W1

Page 17

BOILER MONITOR COMMUNICATIONS JUMPER W1

Located in the upper left hand corner of the "LAST" Boiler Monitor board.

NOTE: The jumper indicates to the System Controller logic that the "Last" wired boiler has been communicated with over the RS485 BUSS Link.

Definition: The "LAST" wired boiler is physically wired with the greatest wire length from the "System Control" or is the last wired boiler for a single or multiple boiler installation.

On a single boiler make sure the W1 Jumper has been installed.

W1

BOILER MONITOR CARD PICTORIAL

On boiler systems the jumper (W1) MUST BE installed on the "Last" wired boiler. This is located on the Boiler Monitor board in the upper left hand corner, adjacent to the RS485 terminals.

On Multiple boiler systems the W1 jumper must be removed from all Boiler Monitor boards except on the "Last" wired boiler.

For normal boiler operation the dip switch settings can be utilized to define any of the boilers as #1 thru # (maximum), independent of the "Last" wired boiler position.

Page 17

Image 17
Contents System Controlboiler Monitor B6000TMPage B6000 Boiler Management System BMS Contents Equipment QuantityTable of Contents System Control Module has ForewordEach Boiler Monitor Module contains Mechanical Installation Installation and MountingInstall Conduit AS Appropriate Dimensions and Weight Check Your Power SourceElectrical Characteristics Electrical Installation VAC Feeder CircuitsInstallation AIR Temperature SensorTypical Water Sensor Water Temperature SensorWater Temperature Sensor Installation Notes Simplified Diagram of Typical Piping To the System Control Module Wiring AIR and Water SensorsBelden #9842 Communication RS 485 WiringWiring Power Source to System Control and Boiler Mod- ules Power Test Boiler Monitor Card Pictorial Boiler Monitor Select SwitchSwitch Boiler Monitor Communications Jumper W1 Optional Boiler Monitor Field Wiring Multiple Boilers Mechanical Installation Installation Verification ProcedureAIR Temperature Sensor Water Temperature SensorSelectable Parameters Range Value System CONTROL/DISPLAY FamiliarizationEditing B6000 Displays Location System Control Module POWER-UPBoiler Monitor Displays System Temperatures Indicates selectable itemInformation only Boiler Valve Firing RatesReadout Boiler StatusHigh Limit No PilotLwco Primary Control Parameters Lead LAG, Night SET BackPush Select Temperature FSet = 135F Ratio Outdoor System 140 150 160 Suggested GuidelinesSecondary Control Parameters Lead Boiler Select StepAutomatic Lead Lag Push Select Pump DelayStandard Boiler Parameters Boiler ParametersSetback Times Am or pm Setback OFF DAY Information only Boiler Valve TimingTarget MIN/MAX and HI LIM ALL Boilers ON/OFFUtility Service Standard Utility ServiceTandard Initialize InitializeStart Alternate Wiring AIR and Water SensorsAlternate Communication RS 485 Wiring Page Alternate Power Test Check Power Fig. # Fig. # System Control Board New CP10.0 90FI Replacement Parts List Boiler Monitor Control BOX Dpdt Call OUT SystemSpdt Select Set Optional Temperature Scale F or C StandardUniversal Select Set OptionTroubleshooting Guide Trouble Shooting Guide Limited Warranty Design and specifications subject to change without notice
Related manuals
Manual 24 pages 53.62 Kb

B6000 specifications

The Raypak B6000 is a high-efficiency boiler designed for residential and commercial heating applications. Known for its reliability and advanced features, the B6000 exemplifies Raypak's commitment to engineering excellence and innovative technology.

One of the standout attributes of the Raypak B6000 is its robust construction. The boiler is built with high-quality materials, ensuring durability and longevity in a variety of environments. It features a compact design, which allows for easy installation even in spaces with limited room. Moreover, it has a user-friendly interface that facilitates straightforward operation and maintenance, making it accessible for both homeowners and HVAC professionals.

The B6000 is equipped with advanced heating technologies that enhance its performance and efficiency. It utilizes a modulating burner system that adjusts the heat output based on the demand, ensuring optimal energy usage. This not only leads to lower energy bills but also contributes to a reduced carbon footprint, making the B6000 an environmentally friendly choice.

Another key feature of the Raypak B6000 is its stainless steel heat exchanger, which provides superior heat transfer and contributes to the boiler's overall efficiency. The heat exchanger is designed to withstand high temperatures and pressures, ensuring safety and reliability throughout its operation. Additionally, the B6000 offers multiple venting options, including direct venting and horizontal venting, providing flexibility in installation.

The B6000 also comes with integrated controls that allow users to easily monitor and adjust settings. These controls can enhance energy efficiency by accommodating varying heating needs throughout the day. Furthermore, the boiler is compatible with smart home systems, enabling remote operation and monitoring.

In terms of safety features, the Raypak B6000 is equipped with multiple safety sensors and shutoff systems to ensure safe operation. This includes automatic shutdown in case of malfunction, preventing potential hazards.

Overall, the Raypak B6000 is a top-tier boiler that combines efficiency, reliability, and advanced technology, making it a preferred choice for those seeking a dependable heating solution. It is suitable for various applications, from residential heating to larger commercial projects, further establishing its versatility in the market. Whether for new installations or replacements, the B6000 stands out as a reliable option for efficient heating solutions.