Raypak B6000 manual Temperature Scale F or C Standard, Select Set Optional, Universal

Page 47

B6000 BOILER MANAGEMENT SYSTEM START-UP DATA SYSTEM SETTINGS ENTERED ON DATE:_____________________________________

 

 

 

 

 

 

 

 

Temperature Scale °F or °C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Standard

 

 

 

 

 

 

 

 

 

 

 

Set _____ Deg.

 

 

 

 

Ratio

 

 

_____ : 1

 

Rise

_____ Deg.

 

 

 

 

System Water Temp. @ Oc

Reset Ratio-Outdoor:

System Design Temp. Diff.

 

 

Default Value 100°F (38°C)

Default Value: 1.0:1

Default Value: 20°F (7°C)

 

 

 

 

 

 

 

 

 

 

 

Select Set Optional

 

 

 

 

 

 

 

 

 

Day _____ Deg.

Nite_____ Deg.

Ratio _____:1

Rise

_____ Deg.

 

 

 

 

System Temps @ Oc

 

 

 

 

Reset Ratio

 

 

System Design Temp. Rise

Default Value

Default Value:

Default Value:

Default Value:

 

 

 

 

100°F (38°C)

 

90°F (32°C)

 

 

1 .0:1

 

 

 

 

20°F (7°C)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Universal

 

 

 

 

 

 

 

 

 

 

 

Step _____ %

O/C_____Deg.

O/Cdb _____Deg.

 

C Band

_____ Deg.

Valve Opening

Outdorr Cutoff

Outdoor Cutoff

 

Control Band

 

 

 

 

Default Value:

Default Value:

Deadband

 

 

 

Default Value:

 

 

5%

 

 

65 degs.

 

 

Default Value: 4 Deg

3 Deg.

 

 

 

 

 

 

Lead

 

 

 

_____

 

 

 

 

# of Boilers

 

_____

 

 

 

 

 

 

Indicates Lead Boiler

 

 

 

 

 

 

Number of Boilers in system.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Lead Change hrs.

_____

 

 

 

Select Set Optional

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Lead boiler will change after selected no. of hours.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Universal

 

 

 

 

 

 

 

 

 

 

 

Pump Delay _____ Min.

 

 

Ign Time _____ Sec.

 

 

 

 

 

 

 

 

 

Delay off pump timing.

 

 

Ignition lockout timing.

 

 

 

 

 

 

 

 

 

Default Value: 3 min.

 

 

Default value: 15 seconds.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Select Set Option

 

 

 

 

 

 

 

 

 

____________

__________

 

 

____________________

_______________

 

 

Time of Day

 

AM or PM

 

 

Day of Week

 

 

 

Set-back- Off or On

 

 

 

 

 

 

 

 

 

 

 

 

Default Value: Monday

Default Value: Off

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Period

 

1

 

 

2

 

 

 

3

 

 

 

4

 

 

5

 

 

 

6

 

 

 

Set-Back

 

On

Off

 

On

 

Off

 

On

 

Off

 

On

 

Off

On

 

Off

 

On

 

Off

Monday

 

___

___

 

___

 

___

 

___

 

___

 

___

 

___

___

 

___

 

___

 

___

Tuesday

 

___

___

 

___

 

___

 

___

 

___

 

___

 

___

___

 

___

 

___

 

___

Wednesday

 

___

___

 

___

 

___

 

___

 

___

 

___

 

___

___

 

___

 

___

 

___

Thursday

 

___

___

 

___

 

___

 

___

 

___

 

___

 

___

___

 

___

 

___

 

___

Friday

 

___

___

 

___

 

___

 

___

 

___

 

___

 

___

___

 

___

 

___

 

___

Saturday

 

___

___

 

___

 

___

 

___

 

___

 

___

 

___

___

 

___

 

___

 

___

Sunday

 

___

___

 

___

 

___

 

___

 

___

 

___

 

___

___

___

___

___

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Proportional Integral Derivative

 

 

 

 

 

 

 

 

____________________

 

 

____________________

 

 

____________________

 

Pconst

 

 

 

 

 

Wait (Integral)

 

 

 

Derivative

 

 

 

 

 

V___________________

Version # of Software

 

 

 

 

 

 

 

 

 

Page 47

Image 47
Contents System Controlboiler Monitor B6000TMPage B6000 Boiler Management System BMS Contents Equipment QuantityTable of Contents System Control Module has ForewordEach Boiler Monitor Module contains Mechanical Installation Installation and MountingElectrical Installation VAC Feeder Circuits Check Your Power SourceInstall Conduit AS Appropriate Dimensions and Weight Electrical CharacteristicsInstallation AIR Temperature SensorTypical Water Sensor Water Temperature SensorWater Temperature Sensor Installation Notes Simplified Diagram of Typical Piping To the System Control Module Wiring AIR and Water SensorsBelden #9842 Communication RS 485 WiringWiring Power Source to System Control and Boiler Mod- ules Power Test Boiler Monitor Card Pictorial Boiler Monitor Select SwitchSwitch Boiler Monitor Communications Jumper W1 Optional Boiler Monitor Field Wiring Multiple Boilers Water Temperature Sensor Installation Verification ProcedureMechanical Installation AIR Temperature SensorSelectable Parameters Range Value System CONTROL/DISPLAY FamiliarizationEditing B6000 Displays Location System Control Module POWER-UPBoiler Monitor Boiler Valve Firing Rates System Temperatures Indicates selectable itemDisplays Information onlyNo Pilot Boiler StatusReadout High LimitLwco Primary Control Parameters Lead LAG, Night SET BackSuggested Guidelines Temperature FPush Select Set = 135F Ratio Outdoor System 140 150 160Secondary Control Parameters Lead Boiler Select StepBoiler Parameters Push Select Pump DelayAutomatic Lead Lag Standard Boiler ParametersSetback Times Am or pm Setback OFF DAY Information only Boiler Valve TimingTarget MIN/MAX and HI LIM ALL Boilers ON/OFFInitialize Standard Utility ServiceUtility Service Tandard InitializeStart Alternate Wiring AIR and Water SensorsAlternate Communication RS 485 Wiring Page Alternate Power Test Check Power Fig. # Fig. # System Control Board New CP10.0 90FI Replacement Parts List Boiler Monitor Control BOX Dpdt Call OUT SystemSpdt Select Set Option Temperature Scale F or C StandardSelect Set Optional UniversalTroubleshooting Guide Trouble Shooting Guide Limited Warranty Design and specifications subject to change without notice
Related manuals
Manual 24 pages 53.62 Kb

B6000 specifications

The Raypak B6000 is a high-efficiency boiler designed for residential and commercial heating applications. Known for its reliability and advanced features, the B6000 exemplifies Raypak's commitment to engineering excellence and innovative technology.

One of the standout attributes of the Raypak B6000 is its robust construction. The boiler is built with high-quality materials, ensuring durability and longevity in a variety of environments. It features a compact design, which allows for easy installation even in spaces with limited room. Moreover, it has a user-friendly interface that facilitates straightforward operation and maintenance, making it accessible for both homeowners and HVAC professionals.

The B6000 is equipped with advanced heating technologies that enhance its performance and efficiency. It utilizes a modulating burner system that adjusts the heat output based on the demand, ensuring optimal energy usage. This not only leads to lower energy bills but also contributes to a reduced carbon footprint, making the B6000 an environmentally friendly choice.

Another key feature of the Raypak B6000 is its stainless steel heat exchanger, which provides superior heat transfer and contributes to the boiler's overall efficiency. The heat exchanger is designed to withstand high temperatures and pressures, ensuring safety and reliability throughout its operation. Additionally, the B6000 offers multiple venting options, including direct venting and horizontal venting, providing flexibility in installation.

The B6000 also comes with integrated controls that allow users to easily monitor and adjust settings. These controls can enhance energy efficiency by accommodating varying heating needs throughout the day. Furthermore, the boiler is compatible with smart home systems, enabling remote operation and monitoring.

In terms of safety features, the Raypak B6000 is equipped with multiple safety sensors and shutoff systems to ensure safe operation. This includes automatic shutdown in case of malfunction, preventing potential hazards.

Overall, the Raypak B6000 is a top-tier boiler that combines efficiency, reliability, and advanced technology, making it a preferred choice for those seeking a dependable heating solution. It is suitable for various applications, from residential heating to larger commercial projects, further establishing its versatility in the market. Whether for new installations or replacements, the B6000 stands out as a reliable option for efficient heating solutions.