Raypak 135A, 195A, 090A manual To Turn OFF GAS to Heater, For Honeywell Valve, For Robertshaw Valve

Page 16

FOR INTERMITTENT IGNITION (IID) WITH HONEY- WELL OR ROBERTSHAW GAS VALVE

1.STOP! Read the safety information above.

2.Set the tankstat to the lowest setting.

3.Turn off all electric power to the appliance.

4.This heater is equipped with an ignition device which automatically lights the pilot. Do not try to light the pilot by hand.

GASCONTROL

KNOBSHOWN

IN "ON"

POSITION

GASINLET

TO TURN OFF GAS TO HEATER

1.Set the tankstat at the lowest setting.

2.Turn off all the electric power to the heater if service is to be performed.

3.For Honeywell Valve:

Turn gas control knob clockwise to "Off". Make sure knob rest against stop.

For Robertshaw Valve:

Push in and move gas control lever to "Off" position.

HONEYWELL

(Models 30 - 90)

5.For Honeywell Valve: Turn gas control knob clockwise to "Off".

For Robertshaw Valve: Push in and move gas control lever to "Off" position.

6.Wait 5 minutes to clear out any gas. If you then smell gas STOP! Follow "B" in the safety informa- tion previously stated. If you don't smell gas, go to the next step.

7.For Honeywell Valve: turn gas control counter- clockwise to "On".

For Robertshaw Valve: Move gas control lever to "On" position.

GASCONTROL

KNOBSHOWN

IN"OFF"

POSITION

GASINLET

ROBERTSHAW

(All Models)

8.Turn on all electric power to the heatler.

9.Set tankstat to desired setting.

10.If the heater will not operate, follow the instruction "To Turn Off Gas To Heater" and call your service technician or gas supplier.

HONEYWELL PILOT

CAUTION: Should overheating occur or the gas supply fails to shut off, DO NOT turn off or disconnect the electrical supply to the pump. Instead, shut off the gas supply at a location external to the heater. Failure to observe this precaution may aggravate the overheated condition resulting in possible damage to the heater and injury to the user.

SECTION 4. Testing the Ignition Safety Shutoff. The ignition system safety shutoff must be tested by conducting the following method of tests:

For Standing Pilot Systems

a. With the main burners on, remove the pilot adjustment cover screw.

*NOTE: There is no pilot adjustment cover on

Robertshaw 7200 gas valve.

b.Insert a small slot screw driver and turn the adjustment screw clockwise until pilot

flame goes out. Note and count number of turns made.

c.Gas valve will shut off main burners after about three (3) minutes. End of test. If the gas valve will not shut off, follow the instructions "To Turn Off Gas To Heater" and call service technician or your gas supplier.

d.Return pilot adjustment screw counter- clock- wise, same number of turns as in step (b)

16

Image 16
Contents Installation Operating Instructions For Your SafetyContents Specifications and Dimensions General SpecificationsReceiving Equipment General Safety Precautions General Safety Precautions Installation Procedures CoderequirementsMountingbase ClearancerequirementsVentingconnections Ansi ZCommon Vents Fig.#GASPRESSURE-SPECIFICATIONS GAS Supply ConnectionsWater Connections & System Piping Relief ValveElectrical Wiring Fig.#Wiring Diagram Intermittent Ignition Device IID Wiring Diagram Standing PilotModels 90, 135 General Location of Controls Servicing ProceduresSequence of Operation Filling the System START-UPPROCEDURESChecking the Circulator Lighting the Heater For Standing Pilot Models For Automatic Ignition ModelsFor Honeywell Valve To Turn OFF GAS to HeaterFor Robertshaw Valve For Automatic Ignition Systems Inspectionprocedures BurnersFlamefailure Raypak Tube Cleaning KIT BurnerdrawerremovalMain Burner and Orifice Removal RepairsectionHeat Exchanger RE-ASSEMBLY Trouble Shooting Guide Important Notice3Pilot Outage Too low or too high gas pressures ADJUSTMENTS/REPLACEMENTSOF Components RAYPAK, INC Replacement Parts ListEastman Avenue Oxnard, CA Fig. # Page Page Limitedpartswarrantyeconopakwaterheaters

090A, 135A, 195A specifications

Raypak, a leading manufacturer in the pool and spa heating industry, presents its advanced line of heaters, specifically the Raypak 195A, 090A, and 135A models. These heaters are renowned for their high performance, durability, and energy efficiency, making them ideal for a variety of applications, including residential and commercial pools and spas.

The Raypak 195A heater stands out with its powerful heating capacity, which is designed to quickly raise water temperatures, ensuring comfortable swimming conditions even in cooler climates. Its compact design allows for easy installation in tight spaces, and it operates quietly, enhancing the user experience. The 090A, meanwhile, is exceptional for smaller pools or spas, delivering reliable heating performance with energy-saving features. This model is particularly popular among homeowners looking to maintain a comfortable temperature without inflating their energy bills.

In contrast, the 135A model offers an impressive balance of power and efficiency, making it suitable for medium-sized pools. It incorporates advanced technologies to minimize energy consumption while maximizing output, allowing users to enjoy their pools while being environmentally conscious.

All three models boast Raypak's innovative digital control system, which provides precise temperature management and easy programming. Users can easily set desired temperatures and schedules, minimizing manual adjustments and enhancing convenience. The built-in diagnostic capabilities alert users to any potential maintenance needs, assuring long-term reliability and performance.

Furthermore, the heaters utilize a copper heat exchanger, known for its exceptional thermal conductivity, which ensures rapid heating and corrosion resistance. The specially designed rust-resistant cabinet protects the internal components from the elements, prolonging the lifespan of the heaters.

In addition to their robust features, these Raypak models are designed for easy maintenance. The streamlined layouts make it simple for service technicians to access vital components, reducing downtime and ensuring efficiency when repairs are necessary.

With their combination of advanced technology, energy efficiency, and user-friendly features, the Raypak 195A, 090A, and 135A models stand as top choices for pool and spa heating solutions. Their reliability and performance make them a valuable addition to any backyard oasis, allowing users to enjoy warm water year-round, regardless of the climate.