ELECTRICAL WIRING

The electrical power supply requirement for these heaters is 115 volts, 60 Hz. Field wiring connections and electrical grounding must comply with the local codes, or in the absence of local codes, with the latest edition of the National Electrical Code, ANSI/NFPA 70. Provide a separate fused circuit from the main electrical panel to the heater, and a disconnecting means within sight of the heater.

Remove the control box cover and make the power supply connections in the field wiring compartment. (See general location of controls drawing on page 13). The pump is supplied and factory wired to operate with the heater.

The thermostat (tankstat) is shipped loose to be installed in the tank at the installation site.

WARNING: SHOCK HAZARD LINE VOLTAGE IS PRESENT. BEFORE SERVICING TANKSTAT OR HEATER, TURN OFF ELECTRICAL POWER TO THE HEATER AT THE MAIN DISCONNECT OR CIRCUIT BREAKER. FAILURE TO DO SO COULD RESULT IN SEVERE PERSONAL INJURY OR DEATH.

WIRING DIAGRAM KEY

NOTE: If it is necessary to replace any of the original wiring, it must be replaced with 105°C wire or its equivalent, except 150° black wire which must be replaced with 150° wire or its equivalent.

Cabinet

Ground

Fig.# 8096.1

11

Image 11
Contents For Your Safety Installation Operating InstructionsContents Receiving Equipment General SpecificationsSpecifications and Dimensions General Safety Precautions General Safety Precautions Clearancerequirements Installation ProceduresCoderequirements MountingbaseAnsi Z VentingconnectionsFig.# Common VentsGAS Supply Connections GASPRESSURE-SPECIFICATIONSRelief Valve Water Connections & System PipingFig.# Electrical WiringModels 90, 135 Wiring Diagram Standing PilotWiring Diagram Intermittent Ignition Device IID Sequence of Operation Servicing ProceduresGeneral Location of Controls Checking the Circulator START-UPPROCEDURESFilling the System For Automatic Ignition Models Lighting the Heater For Standing Pilot ModelsFor Robertshaw Valve To Turn OFF GAS to HeaterFor Honeywell Valve Flamefailure Inspectionprocedures BurnersFor Automatic Ignition Systems Repairsection Raypak Tube Cleaning KITBurnerdrawerremoval Main Burner and Orifice RemovalHeat Exchanger RE-ASSEMBLY Important Notice Trouble Shooting Guide3Pilot Outage Too low or too high gas pressures ADJUSTMENTS/REPLACEMENTSOF Components Eastman Avenue Oxnard, CA Replacement Parts ListRAYPAK, INC Fig. # Page Page Limitedpartswarrantyeconopakwaterheaters

090A, 135A, 195A specifications

Raypak, a leading manufacturer in the pool and spa heating industry, presents its advanced line of heaters, specifically the Raypak 195A, 090A, and 135A models. These heaters are renowned for their high performance, durability, and energy efficiency, making them ideal for a variety of applications, including residential and commercial pools and spas.

The Raypak 195A heater stands out with its powerful heating capacity, which is designed to quickly raise water temperatures, ensuring comfortable swimming conditions even in cooler climates. Its compact design allows for easy installation in tight spaces, and it operates quietly, enhancing the user experience. The 090A, meanwhile, is exceptional for smaller pools or spas, delivering reliable heating performance with energy-saving features. This model is particularly popular among homeowners looking to maintain a comfortable temperature without inflating their energy bills.

In contrast, the 135A model offers an impressive balance of power and efficiency, making it suitable for medium-sized pools. It incorporates advanced technologies to minimize energy consumption while maximizing output, allowing users to enjoy their pools while being environmentally conscious.

All three models boast Raypak's innovative digital control system, which provides precise temperature management and easy programming. Users can easily set desired temperatures and schedules, minimizing manual adjustments and enhancing convenience. The built-in diagnostic capabilities alert users to any potential maintenance needs, assuring long-term reliability and performance.

Furthermore, the heaters utilize a copper heat exchanger, known for its exceptional thermal conductivity, which ensures rapid heating and corrosion resistance. The specially designed rust-resistant cabinet protects the internal components from the elements, prolonging the lifespan of the heaters.

In addition to their robust features, these Raypak models are designed for easy maintenance. The streamlined layouts make it simple for service technicians to access vital components, reducing downtime and ensuring efficiency when repairs are necessary.

With their combination of advanced technology, energy efficiency, and user-friendly features, the Raypak 195A, 090A, and 135A models stand as top choices for pool and spa heating solutions. Their reliability and performance make them a valuable addition to any backyard oasis, allowing users to enjoy warm water year-round, regardless of the climate.