Scotsman Ice SCN60 Maintenance, Scotsman strongly recommends regular, Condenser cleaning

Models: SCN60

1 37
Download 37 pages 22.84 Kb
Page 13
Image 13
Maintenance

SCN60

Installation and Use

Maintenance

Scotsman strongly recommends regular

Winterizing

maintenance of this ice machine. During normal operation mineral scale that is in the water supply will gradually build up on the ice making surfaces. That build up can cause excessive loading of the ice making system, which can cause premature failure. Regular removal of the mineral scale will lengthen the product’s life.

Suggested maintenance schedule: every 6 months.

Type of maintenance: Scale removal, water seal check, water reservoir check, bin drain check, air cooled condenser cleaning and storage bin sanitation.

Condenser cleaning

The condenser is like the radiator on a car, it has fins and tubes that can become clogged with dirt and lint. To clean:

1. Remove the kickplate and front service panel.

Condenser

Surface

2.Locate the condenser surface.

3.Vacuum the surface, removing all dust and lint. Caution: Do not dent the fins.

4.Return the kickplate and front service panel to their original positions. Fasten them to the cabinet using the original screws.

1.Clean the ice making system per the instructions in the Maintenance section.

2.Open the door and push and release the On/Off switch to turn the machine off.

3.Turn off the water supply.

4.Remove the back wall of the ice storage bin.

5.Remove drain plug and drain the water reservoir, return plug to its original position.

6.Drain pump models should have about 1/2 gallon of RV antifreeze (propylene glycol) poured into the ice storage bin drain.

Note: Automotive antifreeze must NOT be used.

7. Switch off and unplug the machine.

May 2011 Page 13

Page 13
Image 13
Scotsman Ice Maintenance, Scotsman strongly recommends regular, Condenser cleaning, SCN60 Installation and Use