SCN60

Service

Bin and Cabinet

The bin and cabinet can be separated from the base. Either the ice making evaporator system must be lifted out and securely suspended or the refrigeration system opened and the connections to the evaporator unbrazed.

1Remove the unit from its installed position.

2Disconnect water supply.

3Disconnect / unplug unit from power supply.

4Drain evaporator.

5Empty bin of ice and water.

6Disconnect drain hose from bottom of bin.

1Remove top, back and side service panels.

7Remove door.

8Remove kickplate.

9Remove front service panel

10Remove screw holding service panel bracket.

11Remove two screws holding baffle at right side of condenser.

12Unplug wires from compressor and fan motor. Be sure wires from control box to base are free and disconnected.

13Remove four screws holding each corner of the chassis to the base.

14Remove two screws holding left rear strut to base.

15Remove one screw holding left side panel to base.

16Either go thru the process to remove gear reducer and evaporator from unit or recover refrigerant and disconnect at evaporator.

Note: If leaving evaporator & gear reducer in unit, have a helper support them while the cabinet is removed.

17 Lift bin and cabinet off chassis.

Auger Motor or Motor Capacitor

1Remove the unit from its installed position.

2Disconnect water supply.

3Disconnect / unplug unit from power supply.

4Empty bin of ice and water.

5Remove top panel.

6Remove both bolts holding motor to gear reducer.

7Lift motor winding and capacitor up and out of machine.

8Cut wires and separate winding from capacitor. Change either and reconnect motor to capacitor.

Note: Be SURE wires are connected per the label

on the motor: Black to Black to Capacitor and Red to Capacitor. If connected incorrectly, motor will turn the wrong way. Output shaft or auger MUST turn CCW (counterclockwise) looking from above or the unit will be damaged during ice making.

9Pull rotor from gear reducer (if changing motor)

10Insert new rotor (if changing motor).

11Reinstall winding and capacitor assembly. Secure with the original screws.

12Return all panels to their original positions.

13Reconnect water and power.

14Reinstall unit.

May 2011 Page 21

Page 37
Image 37
Scotsman Ice SCN60 dimensions Bin and Cabinet, Auger Motor or Motor Capacitor