Performance and Technical Specs

SCN60

Service

Performance and Technical Specs

Overall:

Light Blink Information

Refrigerant: 4.5 oz R-134a

Compressor: Hermetic, 700 BTUH

Condenser: Forced draft

Fan blade: 3 blade, 6 inch

Evaporator: Stainless steel tube, copper coil jacketed
Metering device: Cap tube

Auger drive: output speed 11 RPM

Water valve: Float in reservoir

Drain pump: Magnetic drive, controlled by pressure switch
Bin control: Ultrasonic

Electrical Components:

Compressor - 2.9 to 3.1 amps

Fan motor

Auger motor, amp draw .4 to .5amp

Drain pump motor

Drain pump switch

Controller

Transformer

Water sensor

Ice level sensor

Membrane switch assembly

Control Timers

Power interruption, time to restart after power restored: 2 minutes

Auger motor overload, time to restart: 4 minutes

Auger motor overload, restart window: 60 seconds

Auger motor low current, time to restart: 20 minutes

Auger motor low current, restart window: 60 seconds

Clean cycle time: 40 minutes total.

Note: During the auger motor restart window times, there is no visible indication that the unit is in a restart mode.

All blink once and repeat every 2 seconds: Auger motor overload

All blink twice and repeat every 2 seconds: Auger motor low current

All blink once and repeat every 10 seconds, controller failure.

Water light blinks red: water supply failure

Controller Reset:

Cycle power off and on

Diagnostic Codes: No diagnostic codes are kept

Time to Clean indicator light standard interval to switch light on is 6 months, it can be changed to once per year or disabled.

To Adjust:

1.From Off, press and hold the On/Off and Clean Reset Buttons for 5 seconds.

2.Press and Hold the Clean Reset Button for 5 seconds, then press On/Off. Then press On/off again to cycle thru the settings:

 

Ice Making

Water

Time to

 

Clean

 

 

 

 

 

 

 

6 months

On

Off

Off

1 year

Off

On

Off

 

 

 

 

Disabled

Off

Off

On

 

 

 

 

Light will automatically go out after a few seconds of inactivity. Press Time To Clean to lock in the new setting.

Quick reset of time to clean light: Press and hold the Clean Reset button for 3 seconds.

May 2011