Scotsman Ice dimensions Evaporator Replacement, SCN60 Service

Models: SCN60

1 37
Download 37 pages 22.84 Kb
Page 34
Image 34
Evaporator Replacement

SCN60

Service

Evaporator Replacement

1

Go through all steps to remove the gear

3

Disconnect electrical power.

 

reducer.

 

 

 

 

4

Remove control box cover

2

Add temporary refrigeration system access

 

 

 

valves to the discharge and suction sides of the

5

Unplug all wires.

 

refrigeration system .

 

 

 

 

6

Remove screws holding controller to box.

3

Recover the refrigerant.

 

 

 

 

7

Remove controller.

4

Un-sweat the suction line and cap tube

 

 

 

connections from the evaporator.

8

Before touching replacement controller, touch a

 

 

 

metal surface of the cabinet to discharge any

5

Remove original dryer.

 

static electricity.

6

Attach permanent access valves to system.

9

Place new controller in control box, connect all

 

 

 

wires previously removed.

7

Attach dry nitrogen to system and purge at

 

 

 

about 1 lb pressure while brazing all

10

Reverse remaining steps to reassemble.

 

connections, including access valves, dryer

 

 

 

and evaporator.

Ice level sensor

8

Remove nitrogen source, evacuate system to

1

Pull out to get access to top panel.

 

300 microns or less.

 

 

 

 

2

Remove top panel.

9

Weigh in the nameplate charge.

 

 

 

 

3

Disconnect electrical power.

Water Reservoir

 

 

 

 

4

Remove control box cover

1

Pull unit out to get access to top and back

 

 

 

panel.

5

Unplug wire at J9.

2

Shut water supply off.

 

Ice Level

 

 

 

Sensor

3

Pull drain plug and drain all water. Return plug

 

 

to its original position.

4Loosen nut at water valve inlet and separate inlet tube from reservoir valve.

5Pull outlet hose off reservoir tank.

6Remove screws holding reservoir to unit and lift off.

7

Reverse steps to reassemble.

6

Remove 5 screws and lift sensor from control

 

 

 

box.

Controller

 

 

 

 

7

Replace with new part.

1

Pull out to get access to top panel.

 

 

 

 

8

Reverse remaining steps to reassemble.

2

Remove top panel.

 

 

 

 

May 2011

 

 

Page 18

Page 34
Image 34
Scotsman Ice dimensions Evaporator Replacement, SCN60 Service, Remove 5 screws and lift sensor from control