Service Diagnosis
Problem | Likely Cause | Probable Solution | |
|
| With power on and Ice Making light on, | |
|
| check connector, if secure remove | |
| Ice level sensor failure | connector and jump the two middle pins | |
| at J9 on the controller together. Unit | ||
|
| ||
|
| should start. If it does, replace the | |
|
| sensor, if not, replace the controller. | |
No ice, continued |
| Restart unit. Check for power to | |
|
| ||
| Auger motor on but compressor and fan | compressor and/or fan motor. If none, | |
| replace controller. | ||
| motor are off. | ||
| Ice Making light blinking. Condition is | ||
|
| ||
|
| temporary, unit has been switched off. | |
| Ice making light on, nothing operating. | May be in a restart window. See page 7. | |
| Dirty condenser | Vacuum condenser fins | |
|
|
| |
| Air flow blocked | Check for vent blockage | |
| Gravity drain restricted | Check drain, clear of restriction. Ensure | |
| it has a proper air vent. | ||
|
| ||
Not keeping up, makes | Pump drain slow | Check for proper pump switch operation | |
ice but less than normal | |||
and drainage | |||
| |||
|
| ||
| Scale on evaporator and auger | Clean with scale remover. See | |
| Maintenance section. | ||
|
| ||
| Torn door gasket, door does not close | Check gasket and door fit. | |
| tightly | ||
|
| ||
| Panels vibrating | Check panels, adjust fit, tighten screws | |
|
|
| |
| Fan blade rubbing | Check fan blade for foreign object. | |
| Remove same. Check alignment. | ||
|
| ||
|
|
| |
Makes ice but also an | Scale on evaporator and auger | Clean with scale remover. See | |
Maintenance section. | |||
| |||
unusual noise |
| ||
|
| ||
Drain pump cuts in and out. | Check valve failure, replace. | ||
| |||
| Tubes rubbing | Check for tube contact to panel or | |
| another tube. | ||
|
| ||
| Unit in very cold conditions | Do not operate unit below limits | |
|
|
| |
Water Leak | Drain tube off or cracked | Check/repair drain tube | |
Water inlet connection loose | Check/tighten connection | ||
| |||
Water flows continuously | Float valve not shutting off | Check float, if stuck free it. If leaking by | |
when full, replace the valve. | |||
|
| ||
|
|
| |
|
|
|
May 2011 Page 10