Scotsman Ice SCN60 Service, Service Diagnosis, Problem, Likely Cause, Probable Solution

Models: SCN60

1 37
Download 37 pages 22.84 Kb
Page 26
Image 26
Manual background

SCN60

Service

Service Diagnosis

Problem

Likely Cause

Probable Solution

 

 

With power on and Ice Making light on,

 

 

check connector, if secure remove

 

Ice level sensor failure

connector and jump the two middle pins

 

at J9 on the controller together. Unit

 

 

 

 

should start. If it does, replace the

 

 

sensor, if not, replace the controller.

No ice, continued

 

Restart unit. Check for power to

 

 

 

Auger motor on but compressor and fan

compressor and/or fan motor. If none,

 

replace controller.

 

motor are off.

 

Ice Making light blinking. Condition is

 

 

 

 

temporary, unit has been switched off.

 

Ice making light on, nothing operating.

May be in a restart window. See page 7.

 

Dirty condenser

Vacuum condenser fins

 

 

 

 

Air flow blocked

Check for vent blockage

 

Gravity drain restricted

Check drain, clear of restriction. Ensure

 

it has a proper air vent.

 

 

Not keeping up, makes

Pump drain slow

Check for proper pump switch operation

ice but less than normal

and drainage

 

 

 

 

Scale on evaporator and auger

Clean with scale remover. See

 

Maintenance section.

 

 

 

Torn door gasket, door does not close

Check gasket and door fit.

 

tightly

 

 

 

Panels vibrating

Check panels, adjust fit, tighten screws

 

 

 

 

Fan blade rubbing

Check fan blade for foreign object.

 

Remove same. Check alignment.

 

 

 

 

 

Makes ice but also an

Scale on evaporator and auger

Clean with scale remover. See

Maintenance section.

 

unusual noise

 

 

 

Drain pump cuts in and out.

Check valve failure, replace.

 

 

Tubes rubbing

Check for tube contact to panel or

 

another tube.

 

 

 

Unit in very cold conditions

Do not operate unit below limits

 

 

 

Water Leak

Drain tube off or cracked

Check/repair drain tube

Water inlet connection loose

Check/tighten connection

 

Water flows continuously

Float valve not shutting off

Check float, if stuck free it. If leaking by

when full, replace the valve.

 

 

 

 

 

 

 

 

May 2011 Page 10