Scotsman Ice Service Diagnosis, SCN60 Service, Problem, Likely Cause, Probable Solution

Models: SCN60

1 37
Download 37 pages 22.84 Kb
Page 25
Image 25
Service Diagnosis

SCN60

Service

Service Diagnosis

Problem

Likely Cause

Probable Solution

 

 

 

 

No power

Plug unit into power supply

 

Unit switched off

Push and release on/off button

 

 

 

 

 

Restore water supply, check sensor. If

 

 

RO water is too pure, unit cannot

 

No water, water diagnostic light is on

operate.

 

Check float valve for restriction

 

 

 

 

 

 

 

Check float valve shut off lever position

 

 

Check auger motor for voltage, if none,

 

Compressor on, fan on, auger motor not

replace controller. If there is voltage,

 

operating

check auger motor windings, if open,

 

 

replace auger motor.

 

 

Check evaporator for ice. Thaw out and

 

 

retry. Check top bearing and condition of

 

Compressor on, fan on, auger motor

auger. Replace if worn.

 

Operate unit for a short time with auger

 

cutting off on over amp safety

 

out of machine, water shut off and water

 

 

 

 

sensor bypassed. If auger motor still

 

 

overloads, replace gear reducer.

 

 

 

 

 

Check fan blade for ease of rotation,

No ice

Compressor on, auger on, fan blade not

remove any blockage and retry. Check

turning

fan motor, replace if not turning freely or

 

 

 

motor windings open.

 

 

 

 

Auger motor on, fan on, compressor not

Check compressor start relay, check

 

drawing power

compressor windings.

 

 

 

 

Auger motor on, fan on, compressor

Check compressor. See component

 

cutting off on overload

diagnostics.

 

 

 

 

Compressor on, fan on, auger motor on,

Check ice sweep. If tight to auger, auger

 

is not turning. Gears stripped, replace

 

ice sweep not turning

 

gear reducer.

 

 

 

 

 

 

 

Check connections to auger motor, if

 

Unit off on auger motor open safety

voltage to motor and it does not operate,

 

 

replace motor.

 

 

If pump model check for water back up

 

 

or open safety switch.

 

 

Check transformer, replace if not

 

Unit plugged in but no power

supplying 12 volts AC to controller.

 

Check switch membrane. See

 

 

 

 

component diagnostics.

 

 

If transformer and membrane are good,

 

 

replace controller.

 

 

 