SCN60

Service

Drain Pump (if equipped)

1Shut off water supply

2Remove all ice and/or any standing water.

3Disconnect power or unplug unit

4Uninstall and pull unit out to get access to left side service panel.

5Remove five screws and the service panel.

6Disconnect electrical plug to pump motor

7Disconnect drain hose from pump inlet

8Disconnect discharge hose from pump

9Remove two 3/8 inch nuts holding pump to base, lift pump up and out.

10Reverse steps to reassemble.

Fan Blade or Motor

1If equipped with drain pump follow all steps to remove pump.

2Unplug fan motor connection.

3Remove four screws holding fan motor brackets to shroud.

4Pull fan blade and motor from unit.

5If not equipped with a drain pump:

6Shut off water supply

7Remove all ice and/or any standing water.

8Disconnect power or unplug unit

9Uninstall and pull unit out to get access to left side service panel.

10Remove five screws and the service panel.

11Unplug fan motor connection.

12Remove four screws holding fan motor brackets to shroud.

13Pull fan blade and motor from unit.

11Service blade or motor and reverse to reassemble.