15.Remove breaker & set aside

16.Pull auger from freezer by lifting straight up (be careful as auger has sharp edges!)

Note: If auger does not lift freely, see Auger Removal Procedure.

17.Inspect auger flights for signs of wear

18.Inspect evaporator barrel for signs of radial scoring

19.Remove 4 screws securing gearbox bracket to compartment base

20.Carefully lift and rest gearbox & bracket against back of compartment lip

21.Remove four 5/32” allen head screws holding adapter to evaporator

22.Remove evaporator from gearbox

**tools needed-1/4” & 5/32” allen wrench (T handle or socket type suggested), Phillips screwdriver - 12 inch or longer recommended.

Replace gear reducer and install a new water seal.

May 2011 Page 15

Page 31
Image 31
Scotsman Ice SCN60 dimensions