Raypak B0109, B0147 Regular Care, Pressure Relief Valve, Expansion Control Valve, Service

Page 11

REGULAR CARE

PRESSURE RELIEF VALVE

This valve is located in the in/out header of the water heater and is essential for its safe operation. It is possible for the valve to release a little water through the drain line during each heating period. This occurs as the water is heated and expands by approximately 1/50 of its volume.

Continuous leakage of water from the valve and its drain line may indicate a problem with the water heater (refer to “Pressure Relief Valve Running” on page 10).

WARNING: Never block the outlet of this valve or its drain line for any reason.

Operate the easing lever on the pressure relief valve once every six months. It is very important you raise and

lower the lever gently.

WARNING: Failure to do this may result in the water heater heat exchanger failing.

If water does not flow freely from the drain line when the lever is lifted, then the water heater should be checked by your installing plumber, or phone your nearest Rheem Service Department or Accredited Service Agent.

The pressure relief valve should be checked for performance or replaced at intervals not exceeding 5 years, or more frequently in areas where there is a high incidence of water deposits (refer to “Water Supplies” on page 39).

EXPANSION CONTROL VALVE

In many areas, including South Australia, Western Australia and scaling water areas, an expansion control valve is fitted to the cold water line to the water heating system. The expansion control valve may discharge a small quantity of water from its drain line during the heating period instead of the pressure relief valve on the water heater.

Operate the easing lever on the expansion control valve once every six months. It is very important you raise and lower the lever gently. The expansion control valve should be checked for performance or replaced at intervals not exceeding 5 years, or more frequently in areas where there is a high incidence of water deposits.

STORAGE TANKS (If fitted)

Refer to the owners guide and installation instructions supplied with the storage tank for details on regular care required.

SERVICE

For efficient operation the water heater should be serviced annually by your nearest Rheem Service Department or Accredited Service Agent. Only genuine replacement parts should be used on this water heater.

WARNING: Servicing of a gas water heater should only be carried out by authorised personnel.

11

Image 11
Contents Raypak Water Heaters Patents Contents HOW HOT should the Water BE? Temperature AdjustmentAbout Your Water Heater Model TypeTo Turn OFF the Water Heater SafetyWhat to do if YOU Smell GAS? HOW Long will the Water Heater LAST? HOW do I Know if the Water Heater is Installed CORRECTLY?To Turn on the Water Heater Does the Water Quality Affect the Water HeaterOn/Off Operation HOW Your Water Heater WorksMains Pressure Models147 On/Off Models Burner IgnitionAll 109 and 147 Hi/Lo Models Water Heater not Operating Save a Service CallDiagnostic Features of Electronic Thermostat Not Enough HOT Water or no HOT WaterHigh GAS Bills Burner will not LightPressure Relief Valve Running Expansion Control Valve RunningExpansion Control Valve ServiceRegular Care Pressure Relief ValveWater Heater Location InstallationIndoor Installation Inspection of EquipmentSafe Tray Clearances Indoor InstallationsOutdoor Installation Combustion / Ventilation AIRInstallation Tank Water Supply High Wind ConditionsCold Water Supply Indoor Conversions HOT Water Delivery Water Heating ApplicationsReducing Heat Losses Water Heating Applications Hood Conversion147 Dimensions and Technical Data109 Models Pipe Sizes Connections PlumbingWater Inlet and Outlet GAS InletRelief Valve Drain Model Pump Branch Size Minimum Manifold HeaderPump Selection Relief Valve Pressure RatingWater Heating Typical Mechanical Heating InstallationTypical Water Heating Installation Mechanical HeatingIntermittent Pump Operation Thermostat SettingConnections Electrical 109 147 On/OffBuilding Management System BMS Wiring a Power Flued System to the Water HeaterControl Panel Access Wiring Diagram 109 ON/OFF Models Wiring Diagram 109 HI/LO Models Wiring Diagram 147 ON/OFF Models Wiring Diagram 147 HI/LO Models Multi Pump Option Mechanical Heating Systems Rating Label Location of ControlsThermostat GAS ControlAfter Handling Safety PrecautionsWhen Handling During First Firing of the Water HeaterOperational Checks CommissioningPRE-START Checks Operating the Water Heater To Reset the Water HeaterGAS Inlet Pressure Burner Pressure AdjustmentGAS Pressure Adjustment 109 On/Off Models 147 Hi/Lo Models 109 Hi/Lo ModelsDifferential Adjustment Temperature ControlThermostat Adjustment 147 On/Off models AKO Thermostat Set Point Adjustment147 Hi/Low Models CTX Thermostat Set Point Adjustment Water Heating Applications 90C maximum HIGH-LIMIT Thermostat AdustmentAnnual Service Procedure Service ProceduresSix Monthly Service Procedure Change of Water Supply Water SuppliesSaturation Index Water Quality Charts Warranty Exclusions Warranty131 031 Australia Raypak Water Heater Warranty Australia only96109147B

B0109, B0147 specifications

Raypak is a well-established name in the world of heating technology, particularly recognized for its efficient and reliable pool and spa heaters. Among their range, the Raypak B0147 and B0109 models stand out for their performance and advanced features designed to enhance user experience.

Both the Raypak B0147 and B0109 models prioritize efficiency, making them ideal choices for residential or commercial swimming pools. They are engineered to deliver reliable heating, ensuring that water maintains a comfortable temperature no matter the season. One of the standout features is their compact design, which allows for easy installation in various settings without requiring extensive modifications to existing infrastructure.

A key characteristic of the Raypak B0147 is its digital control system. This advanced technology allows users to set precise temperatures and monitor heater performance. The intuitive interface makes it user-friendly, facilitating adjustments on-the-fly. The B0109 model, meanwhile, offers robust heating capabilities, featuring a high-output design that can rapidly elevate water temperatures, perfect for pools with significant heat loss.

Both models utilize a copper-fin-tube heat exchanger, which enhances heat transfer efficiency and extends the lifespan of the heater. This design not only improves thermal efficiency but also ensures that users experience lower energy bills over time. They also come equipped with a dependable ignition system, featuring an automatic spark ignition that eliminates the need for pilot lights, leading to improved safety and reliability.

Durability is another hallmark of the Raypak line. Both models are constructed with materials designed to withstand harsh weather conditions and exposure to pool chemicals, ensuring longevity. The corrosion-resistant housings prevent degradation, maintaining the heater's performance over time.

In summary, the Raypak B0147 and B0109 models deliver outstanding heating performance through efficient technology and durable construction. Their user-friendly controls, compact design, and energy-efficient heat exchangers make them excellent choices for pool owners looking to optimize their heating solutions. With Raypak, users can enjoy comfortable water temperatures year-round, backed by reliable technology and impressive efficiency.