CONNECTIONS – PLUMBING

IMPORTANT: When installing a new water heater to an old or existing system, it is a requirement that the system and its equipment be thoroughly inspected and if necessary, drained and flushed with clean fresh water, before the new water heater is connected. Failure to do this may cause blockages and/or damage to the water heater which is not covered by warranty.

IF THERE IS ANY DOUBT ABOUT THE SYSTEM, DRAIN AND FLUSH AS A PRECAUTION. CONNECTION SIZES

 

109 On/Off

109 Hi/Lo

147 On/Off

147 Hi/Lo

Inlet water connection

RP1¼/32

RP1¼/32

RP1¼/32

RP1¼/32

Outlet water connection

RP1¼/32

RP1¼/32

RP1¼/32

RP1¼/32

Relief valve connection

RP½/15

RP½/15

RP¾/20

RP¾/20

Gas inlet

R¾/20

R¾/20

RP¾/20

RP½/15

All plumbing work must be carried out by a qualified person and in accordance with the National Plumbing Standard AS/NZS 3500.4 and local authority requirements.

All gas work must be carried out by a qualified person and in accordance with the Australian Gas Installations Standard AS 5601 and local authority requirements.

WATER INLET AND OUTLET

All pipe work must be cleared of foreign matter before connection and purged before attempting to operate the water heater. All olive compression fittings must use brass or copper olives. Use thread sealing tape or approved thread sealant on all fittings.

An isolation valve and non-return valve must be installed on the cold water line to the water heating system. An acceptable arrangement is shown in the diagram opposite for a water heating application.

A disconnection union must always be provided at the inlet and outlet on the water heater to allow for disconnection of the water heater.

Do not reduce the pipe work size and water heater water connections without allowing for friction loss which will occur. Low water flow will cause damage to the water heater and system components.

GAS INLET

The gas connection is made at the right hand end of the water heater for 109 Models and at the inlet of the gas control for 147 models. The pipe work must be cleared of foreign matter before connection and purged before attempting to light the water heater. An isolation valve and disconnection union must be used to allow servicing and removal of the water heater.

Refer to the Gas Installations Standard AS 5601 for the correct method of sizing the gas supply pipe to the water heater.

WARNING: Before pressure testing the gas supply system always isolate and disconnect the water heater after the isolating cock to prevent the risk of serious damage to the gas control. Warranty does not cover damage of any nature resulting from failure to observe this precaution. Refer to rating label for gas types and pressures.

Ensure the gas line is also purged at the union connection to the water heater. If this procedure is not followed, a retry lockout may result on initial start up.

CAUTION: Care is necessary when tightening fittings into the gas control. The gas control casting may crack if the fittings are over tightened. Cracked castings are not covered under warranty. Damaged gas controls must be replaced.

PIPE SIZES

The pipe sizing for water heating and mechanical heating systems should be carried out by persons competent to do so, choosing the most suitable pipe size for each individual application. Reference to the technical specifications of the water heater and local regulatory authority requirements must be made.

19

Image 19
Contents Raypak Water Heaters Patents Contents HOW HOT should the Water BE? Temperature AdjustmentAbout Your Water Heater Model TypeWhat to do if YOU Smell GAS? SafetyTo Turn OFF the Water Heater HOW Long will the Water Heater LAST? HOW do I Know if the Water Heater is Installed CORRECTLY?To Turn on the Water Heater Does the Water Quality Affect the Water HeaterOn/Off Operation HOW Your Water Heater WorksMains Pressure ModelsAll 109 and 147 Hi/Lo Models Burner Ignition147 On/Off Models Water Heater not Operating Save a Service CallDiagnostic Features of Electronic Thermostat Not Enough HOT Water or no HOT WaterHigh GAS Bills Burner will not LightPressure Relief Valve Running Expansion Control Valve RunningExpansion Control Valve ServiceRegular Care Pressure Relief ValveWater Heater Location InstallationIndoor Installation Inspection of EquipmentSafe Tray Clearances Indoor InstallationsOutdoor Installation Combustion / Ventilation AIRInstallation Cold Water Supply High Wind ConditionsTank Water Supply Indoor Conversions HOT Water Delivery Water Heating ApplicationsReducing Heat Losses Water Heating Applications Hood Conversion109 Dimensions and Technical Data147 Models Pipe Sizes Connections PlumbingWater Inlet and Outlet GAS InletRelief Valve Drain Model Pump Branch Size Minimum Manifold HeaderPump Selection Relief Valve Pressure RatingWater Heating Typical Mechanical Heating InstallationTypical Water Heating Installation Mechanical HeatingIntermittent Pump Operation Thermostat SettingConnections Electrical 109 147 On/OffControl Panel Access Wiring a Power Flued System to the Water HeaterBuilding Management System BMS Wiring Diagram 109 ON/OFF Models Wiring Diagram 109 HI/LO Models Wiring Diagram 147 ON/OFF Models Wiring Diagram 147 HI/LO Models Multi Pump Option Mechanical Heating Systems Rating Label Location of ControlsThermostat GAS ControlAfter Handling Safety PrecautionsWhen Handling During First Firing of the Water HeaterPRE-START Checks CommissioningOperational Checks Operating the Water Heater To Reset the Water HeaterGAS Pressure Adjustment 109 On/Off Models Burner Pressure AdjustmentGAS Inlet Pressure 147 Hi/Lo Models 109 Hi/Lo ModelsDifferential Adjustment Temperature ControlThermostat Adjustment 147 On/Off models AKO Thermostat Set Point Adjustment147 Hi/Low Models CTX Thermostat Set Point Adjustment Water Heating Applications 90C maximum HIGH-LIMIT Thermostat AdustmentSix Monthly Service Procedure Service ProceduresAnnual Service Procedure Saturation Index Water SuppliesChange of Water Supply Water Quality Charts Warranty Exclusions Warranty131 031 Australia Raypak Water Heater Warranty Australia only96109147B

B0109, B0147 specifications

Raypak is a well-established name in the world of heating technology, particularly recognized for its efficient and reliable pool and spa heaters. Among their range, the Raypak B0147 and B0109 models stand out for their performance and advanced features designed to enhance user experience.

Both the Raypak B0147 and B0109 models prioritize efficiency, making them ideal choices for residential or commercial swimming pools. They are engineered to deliver reliable heating, ensuring that water maintains a comfortable temperature no matter the season. One of the standout features is their compact design, which allows for easy installation in various settings without requiring extensive modifications to existing infrastructure.

A key characteristic of the Raypak B0147 is its digital control system. This advanced technology allows users to set precise temperatures and monitor heater performance. The intuitive interface makes it user-friendly, facilitating adjustments on-the-fly. The B0109 model, meanwhile, offers robust heating capabilities, featuring a high-output design that can rapidly elevate water temperatures, perfect for pools with significant heat loss.

Both models utilize a copper-fin-tube heat exchanger, which enhances heat transfer efficiency and extends the lifespan of the heater. This design not only improves thermal efficiency but also ensures that users experience lower energy bills over time. They also come equipped with a dependable ignition system, featuring an automatic spark ignition that eliminates the need for pilot lights, leading to improved safety and reliability.

Durability is another hallmark of the Raypak line. Both models are constructed with materials designed to withstand harsh weather conditions and exposure to pool chemicals, ensuring longevity. The corrosion-resistant housings prevent degradation, maintaining the heater's performance over time.

In summary, the Raypak B0147 and B0109 models deliver outstanding heating performance through efficient technology and durable construction. Their user-friendly controls, compact design, and energy-efficient heat exchangers make them excellent choices for pool owners looking to optimize their heating solutions. With Raypak, users can enjoy comfortable water temperatures year-round, backed by reliable technology and impressive efficiency.