Raypak B0147 HOT Water Delivery Water Heating Applications, Hood Conversion, Indoor Conversions

Page 16

INSTALLATION

HOT WATER DELIVERY (WATER HEATING APPLICATIONS)

This water heater can deliver water at temperatures which can cause scalding.

It is necessary and we recommend that a temperature limiting device be fitted between the water heating system and the hot water outlets in any ablution and public areas such as bathrooms, ensuites or public amenities, to reduce the risk of scalding. The installing plumber may have a legal obligation to ensure the installation of this water heater meets the delivery water temperature requirements of AS/NZS 3500.4 so that scalding water temperatures are not delivered to a bathroom, ensuite, or other ablution or public area.

Where a temperature limiting device is installed adjacent to the hot water storage tanks, the cold water line to the temperature limiting device can be branched off the cold water line either before or after the isolation valve, pressure limiting valve and non return valve to the storage tanks. If an expansion control valve is required, it must always be installed after the non return valve and be the last valve prior to the water heating system.

If a pressure limiting valve is installed on the cold water line to the water heating system and the cold water line to a temperature limiting device branches off before this valve or from another cold water line in the premises, then a pressure limiting valve of an equal pressure setting may be required prior to the temperature limiting device.

REDUCING HEAT LOSSES (WATER HEATING APPLICATIONS)

The cold water line to and the hot water line from the storage cylinder must be insulated in accordance with the requirements of AS/NZS 3500.4. The insulation must be weatherproof and UV resistant if exposed.

Keep temperature settings down. Lower temperatures reduce heat losses and prolong storage cylinder life. Do not set the controlling electronic thermostat above 70°C unless it is necessary. A time clock to control the electrical supply can be used to switch off the water heater during hours or days when it is not in use.

HOOD CONVERSION

To convert a water heater from an outdoor configuration to an Indoor or High Wind Top configuration, proceed as follows:

1.Remove the flue terminal (outdoor hood) from the water heater leaving the jacket top in place.

2.Place the stack adaptor over the flue collector and secure into place with self tapping screws.

3.Fit the draft diverter over the spigot and sit squarely on the stack adapter. Secure in place using self tapping screws.

4.(Indoor installations only) Install and connect the secondary flue to the draft diverter in accordance with the requirements of AS 5601.

NOTE: For High Wind Top conversion (147 models only) follow steps 1 to 3 and assess whether tie downs for the High Wind Cowl are required.

109 Indoor Conversions

16

Image 16
Contents Raypak Water Heaters Patents Contents Temperature Adjustment About Your Water HeaterModel Type HOW HOT should the Water BE?What to do if YOU Smell GAS? SafetyTo Turn OFF the Water Heater HOW do I Know if the Water Heater is Installed CORRECTLY? To Turn on the Water HeaterDoes the Water Quality Affect the Water Heater HOW Long will the Water Heater LAST?HOW Your Water Heater Works Mains PressureModels On/Off OperationAll 109 and 147 Hi/Lo Models Burner Ignition147 On/Off Models Save a Service Call Diagnostic Features of Electronic ThermostatNot Enough HOT Water or no HOT Water Water Heater not OperatingBurner will not Light Pressure Relief Valve RunningExpansion Control Valve Running High GAS BillsService Regular CarePressure Relief Valve Expansion Control ValveInstallation Indoor InstallationInspection of Equipment Water Heater LocationClearances Indoor Installations Outdoor InstallationCombustion / Ventilation AIR Safe TrayInstallation Cold Water Supply High Wind ConditionsTank Water Supply HOT Water Delivery Water Heating Applications Reducing Heat Losses Water Heating ApplicationsHood Conversion Indoor Conversions109 Dimensions and Technical Data147 Models Connections Plumbing Water Inlet and OutletGAS Inlet Pipe SizesModel Pump Branch Size Minimum Manifold Header Pump SelectionRelief Valve Pressure Rating Relief Valve DrainTypical Mechanical Heating Installation Typical Water Heating InstallationMechanical Heating Water HeatingThermostat Setting Connections Electrical109 147 On/Off Intermittent Pump OperationControl Panel Access Wiring a Power Flued System to the Water HeaterBuilding Management System BMS Wiring Diagram 109 ON/OFF Models Wiring Diagram 109 HI/LO Models Wiring Diagram 147 ON/OFF Models Wiring Diagram 147 HI/LO Models Multi Pump Option Mechanical Heating Systems Location of Controls ThermostatGAS Control Rating LabelSafety Precautions When HandlingDuring First Firing of the Water Heater After HandlingPRE-START Checks CommissioningOperational Checks To Reset the Water Heater Operating the Water HeaterGAS Pressure Adjustment 109 On/Off Models Burner Pressure AdjustmentGAS Inlet Pressure 109 Hi/Lo Models 147 Hi/Lo ModelsTemperature Control Thermostat Adjustment147 On/Off models AKO Thermostat Set Point Adjustment Differential Adjustment147 Hi/Low Models CTX Thermostat Set Point Adjustment HIGH-LIMIT Thermostat Adustment Water Heating Applications 90C maximumSix Monthly Service Procedure Service ProceduresAnnual Service Procedure Saturation Index Water SuppliesChange of Water Supply Water Quality Charts Warranty Warranty ExclusionsRaypak Water Heater Warranty Australia only 131 031 Australia96109147B

B0109, B0147 specifications

Raypak is a well-established name in the world of heating technology, particularly recognized for its efficient and reliable pool and spa heaters. Among their range, the Raypak B0147 and B0109 models stand out for their performance and advanced features designed to enhance user experience.

Both the Raypak B0147 and B0109 models prioritize efficiency, making them ideal choices for residential or commercial swimming pools. They are engineered to deliver reliable heating, ensuring that water maintains a comfortable temperature no matter the season. One of the standout features is their compact design, which allows for easy installation in various settings without requiring extensive modifications to existing infrastructure.

A key characteristic of the Raypak B0147 is its digital control system. This advanced technology allows users to set precise temperatures and monitor heater performance. The intuitive interface makes it user-friendly, facilitating adjustments on-the-fly. The B0109 model, meanwhile, offers robust heating capabilities, featuring a high-output design that can rapidly elevate water temperatures, perfect for pools with significant heat loss.

Both models utilize a copper-fin-tube heat exchanger, which enhances heat transfer efficiency and extends the lifespan of the heater. This design not only improves thermal efficiency but also ensures that users experience lower energy bills over time. They also come equipped with a dependable ignition system, featuring an automatic spark ignition that eliminates the need for pilot lights, leading to improved safety and reliability.

Durability is another hallmark of the Raypak line. Both models are constructed with materials designed to withstand harsh weather conditions and exposure to pool chemicals, ensuring longevity. The corrosion-resistant housings prevent degradation, maintaining the heater's performance over time.

In summary, the Raypak B0147 and B0109 models deliver outstanding heating performance through efficient technology and durable construction. Their user-friendly controls, compact design, and energy-efficient heat exchangers make them excellent choices for pool owners looking to optimize their heating solutions. With Raypak, users can enjoy comfortable water temperatures year-round, backed by reliable technology and impressive efficiency.