OPERATING INSTRUCTIONS
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
BEFORE OPERATING: ENTIRE SYSTEM MUST BE FILLED WITH WATER AND AIR PURGED AT FAUCETS.
A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.
B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some
gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS:
•Do not try to light any appliance.
•Do not touch any electric switch; do not use any phone in your building.
•Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
•If you cannot reach your gas supplier, call the fire department.
C.Use only your hand to push down or turn the gas control knob. Never use tools. If the knob will not push down or turn by hand, don’t try to repair it, call a qualified service technician . Force or attempted repair may result in a fire or explosion.
D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
LIGHTING INSTRUCTIONS
|
|
|
|
|
|
|
|
|
| FIGURE D. | ||
| FIGURE 1. |
|
|
| TOP VIEW |
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| ||||
1. | STOP! | Read the safety information above | 8. | Push gas control knob down all the way and hold it | ||||||||
| on this label. |
|
|
|
| down. Immediately light pilot with a match. Continue to | ||||||
2. | Set the thermostat to lowest setting by turning thermostat |
| hold the gas control knob down for about one (1) minute | |||||||||
| dial fully clockwise | until it stops. |
|
| after the pilot is lit. Release the gas control knob and it | |||||||
|
|
| will pop back up. Pilot should remain lit. If it goes out, | |||||||||
3. | Push the gas control knob down slightly and turn |
| ||||||||||
| repeat Steps 3 through 8. It may take several minutes | |||||||||||
| clockwise | to “OFF”, (Figure “A”). |
|
| for air to clear the lines before the pilot will light. | |||||||
| NOTE:Gas control knob CANNOT be turned from “PILOT” |
| • If knob does not pop up when released, stop and | |||||||||
| to “OFF” unless it is pushed down slightly. Do not force. |
| immediately call your service technician or gas | |||||||||
4. | Remove inner and outer burner doors located below |
| supplier. |
|
| |||||||
| • If the pilot will not stay lit after several tries, turn | |||||||||||
| and behind the gas control unit. |
|
| |||||||||
|
|
| the gas control knob to "OFF" (Figure A) and call | |||||||||
5. | Wait five (5) minutes to clear out any gas. If |
|
| |||||||||
|
| your service technician or gas supplier. | ||||||||||
| you then smell gas |
| STOP! Follow “B” in the |
| ||||||||
|
| 9. | Replace inner and outer burner doors. | |||||||||
| safety information |
| above on this label. | |||||||||
|
| 10. | At arm’s length away, turn control knob | |||||||||
| If you don’t smell gas, go to next step. |
| ||||||||||
|
|
| counterclockwise | to on. (Figure “C”). | ||||||||
6. | Find pilot. Follow metal tube from the bottom, right of the |
| ||||||||||
11. | Set thermostat to desired setting. (See Figure 1). | |||||||||||
| gas control to the pilot burner, |
| ||||||||||
|
|
|
|
|
|
| ||||||
| (Figure “D”). |
|
|
|
|
| CAUTION: Hotter water increases the | |||||
7. | Turn gas control knob counterclockwise to | “PILOT”. |
| |||||||||
| risk of scald injury. Consult the instruction | |||||||||||
| (Figure “B”). |
|
|
|
|
| manual before changing temperature. | |||||
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
| TO TURN OFF GAS TO APPLIANCE |
|
| |||||
1. | Set thermostat to the lowest setting. |
| 2. Push gas control knob down slightly and turn clockwise | |||||||||
|
|
|
|
|
|
|
| to “OFF”. Do not force. SEE FIGURE “A”. | ||||
|
|
|
|
|
|
|
|
|
|
|
|