Maytag HXN4975S manual Operational Conditions, Smoke / Odor

Page 25

Good venting is essential for a gas fired water heater to operate properly as well as to carry away products of combustion and water vapor.

Smoke / Odor

It is not uncommon to experience a small amount of smoke and odor during the initial start-up. This is due to burning off of oil from metal parts, and will disappear in a short while.

Thermal Expansion

Water supply system may, because of such events as high line pressure, frequent cut-offs, the effects of water hammer among others, have installed devices such as pressure reducing valves, check valves, back flow preventers, etc., to control these types of problems. When these devices are not equipped with an internal by-pass, and no other measures are taken, the devices cause the water system to be closed. As water is heated, it expands (thermal expansion) and closed systems do not allow for the expansion of heated water.

The water within the water heater tank expands as it is heated and increases the pressure of the water system. If the relieving point of water heater’s temperature-pressure relief valve is reached, the valve will relieve the excess pressure. The temperature-pressure relief valve is not intended for the constant relief of thermal expansion. This is an unacceptable condition and must be corrected.

It is recommended that any devices installed which could create a closed system have a by-pass and/or the system have an expansion tank or device to relieve the pressure built by thermal expansion in the water system. Thermal expansion tanks are available for ordering through the Maytag Customer Service Center (1-800-788-8899). Contact the local plumbing inspector, water supplier and/or call Maytag Customer Service at 1-800-788-8899 for assistance in controlling these situations.

Strange Sounds

Possible noises due to expansion and contraction of some metal parts during periods of heat-up and cool-down do not represent harmful or dangerous conditions.

Condensation causes sizzling and popping within the burner area during heating and cooling periods and should be considered normal. See Condensation section.

Operational Conditions

Smelly Water

In each water heater there is installed at least one anode rod (see parts section) for corrosion protection of the tank. Certain

water conditions will cause a reaction between this rod and the water. The most common complaint associated with the anode rod is one of a “rotten egg smell”. This odor is derived

from hydrogen sulfide gas dissolved in the water. The smell is the result of four factors which must all be present for the odor to develop:

a concentration of sulfate in the supply water.

little or no dissolved oxygen in the water.

a sulfate reducing bacteria within the water heater. (This harmless bacteria is non-toxic to humans.)

an excess of active hydrogen in the tank. This is caused by the corrosion protective action of the anode.

Smelly water may be eliminated or reduced in some water heater models by replacing the anode(s) with one of less active material, and then chlorinating the water heater tank and all hot water lines. Contact Maytag Customer Service at 1-800-788-8899 for further information concerning an Anode Replacement Kit and this Chlorination Treatment.

If the smelly water persists after the anode replacement and chlorination treatment, we can only suggest that chlorination or aeration of the water supply be considered to eliminate the water problem.

Do not remove the anode leaving the tank unprotected. By doing so, all warranty on the water heater tank is voided.

“AIR” In Hot Water Faucets

HYDROGEN GAS: Hydrogen gas can be produced in a hot water system that has not been used for a long period of time (generally two weeks or more). Hydrogen gas is extremely flammable and explosive. To prevent the possibility of injury under these conditions, we recommend the hot water faucet, located farthest away, be opened for several minutes before any electrical appliances which are connected to the hot water system are used (such as a dishwasher or washing machine). If hydrogen gas is present, there will probably be an unusual sound similar to air escaping through the pipe as the hot water faucet is opened. There must be no smoking or open flame near the faucet at the time it is open.

High Temperature Shut Off System

This water heater is equipped with an automatic gas Shut-off system. This system works when high water temperatures are present. The high temperature Shut-off is built into the gas control valve. It is non-resettable. If the high temperature Shut-off activates, the gas control valve must be replaced. Turn

25

Image 25
Contents Series Nine Important Definitions Safe INSTALLATION, USE and ServiceSafety Precautions Table of Contents Customer Responsibilities Product SpecificationsAccessories Accessories and Tools NeededAdditional Tools Needed When Sweat Soldering ToolsRemoving the Old Water Heater Preparations for InstallationGET to Know Your Water Heater GAS Models Typical InstallationMixing Valve Usage Facts to Consider About the Location Locating and Installing the NEW Water HeaterInsulation Blankets ALL AIR from Inside Buildings See Figures 10 Water Piping Temperature-Pressure Relief Valve Filling the Water Heater Venting Gas Piping Sediment Traps GAS Piping with Flexible ConnectorOperating Instructions For Your Safety Read Before Lighting Temperature Time to Produce 2nd & 3rd Temperature RegulationTank Sediment Cleaning Service and MaintenanceBurner Cleaning Vent System InspectionHousekeeping Temperature-Pressure Relief Valve OperationAnode Rod Inspection DrainingDrain Valve Washer Replacement TroubleshootingService Start Up ConditionsSmoke / Odor Operational ConditionsLeakage Checkpoints Problem Cause Solution Troubleshooting GuideMaytag GAS Water Heaters Repair Parts ListPage Page Page Warranty Series Nine Avertissement INSTALLATION, Utilisation ET Entretien SécuritairesMesures DE Sécurité Table DES Matières Choix DE L’EMPLACEMENT DU CHAUFFE-EAU ET InstallationSpécifications Techniques DU Produit Responsabilité DU ClientAccessoires Accessoires ET Outils NécessairesOutils Outils supplémentaires requis pour la soudure à l’étainEnlèvement de l’ancien chauffe-eau Préparation À L’INSTALLATIONDescription DU CHAUFFE-EAU AU GAZ Installation TypeUtilisation D’UN Robinet Mélangeur Points à considérer dans le choix de l’emplacement Choix DE L’EMPLACEMENT DU CHAUFFE-EAU ET InstallationRevêtements isolants Air de combustion et air de ventilation en espace clos Air de combustion et air de ventilation en espace ouvertTuyauterie d’eau Soupape de décharge à sécurité thermique Remplissage du chauffe-eau Ventilation Tuyauterie de gaz Tuyauterie DE Gazavec Raccord Flexible Collecteur d’impuretésPage Pour Votre Sécurité Lisez Avant D’ALLUMER Réglage de la température Nettoyage du réservoir dépôts Entretien ET RéparationInspection du système de ventilation Inspection du brûleurInspection de la tige d’anode Entretien courantVidange Situations pouvant se produire à la mise en service Remplacement de la rondelle du robinet de vidangeGuide DE Dépannage Fumée et odeur Conditions de fonctionnementPoints de vérification des fuites Problème Cause Solution CHAUFFE-EAU AU GAZ Maytag Liste DES Pièces DE RechangePage Page Page Garantie

HXN4975S specifications

The Maytag HXN4975S is a state-of-the-art refrigerator that perfectly balances innovation, style, and functionality. Designed for modern kitchens, this model stands out with its stainless steel finish, which not only adds a sleek aesthetic but also ensures durability and resistance to fingerprints and smudges.

One of the standout features of the HXN4975S is its generous storage capacity. With multiple shelves and adjustable compartments, it provides ample space for groceries of all sizes. The fridge section includes spill-proof glass shelves that are easy to clean and prevent spills from cascading down to lower shelves, maintaining cleanliness effortlessly. Enhanced storage options like gallon door bins and humidity-controlled crisper drawers make it easy to store and organize a variety of items.

The HXN4975S is equipped with advanced cooling technologies. Its dual cooling system ensures optimal temperature and humidity levels, keeping your food fresh longer. This technology separates the airflow between the refrigerator and freezer, preventing the transfer of odors and maintaining the quality of stored food. Additionally, the refrigerator incorporates a powerful compressor that efficiently maintains the desired temperatures while reducing energy consumption.

Another key feature of the Maytag HXN4975S is its smart connectivity. With built-in Wi-Fi, users can control their refrigerator remotely through a compatible smartphone app. This feature allows for adjustments to be made on-the-go, enabling users to monitor temperatures, receive alerts, and even diagnose issues without the need for a technician.

Energy efficiency is also a priority for the HXN4975S, as it is ENERGY STAR rated. This ensures that the refrigerator not only saves on energy bills but also contributes to a greener environment. The LED lighting inside the unit provides bright illumination while consuming minimal energy, allowing for excellent visibility regardless of the time of day.

The Maytag HXN4975S also focuses on user-friendly features, such as its intuitive temperature control and ice and water dispenser located conveniently on the front door. The sleek design incorporates a filtered water system, providing clean and safe drinking water instantly.

Overall, the Maytag HXN4975S embodies a commitment to quality and efficiency, catering to the needs of busy families while enhancing the kitchen's functionality and style. This refrigerator truly stands out as a reliable appliance designed with both performance and user experience in mind.