Maytag HXN4975S manual Water Piping

Page 13

Water Piping

FIGURE 13.

When communicating with the outdoors through horizontal ducts, each opening shall have a minimum free area of 1 square inch per 2,000 BTU per hour (11 cm2/kW) of total input rating of all equipment in the enclosure, see Figure 14.

When ducts are used, they shall be of the same cross- sectional area as the free area of the openings to which they connect. The minimum short side dimension of rectangular

air ducts shall not be less than 3 inches (76.2 mm), see Figure 14.

FIGURE 14.

Louvers and Grilles: In calculating free area, consideration shall be given to the blocking effect of louvers, grilles or screens protecting openings. Screens used shall not be smaller than 1/4 inch (6.4 mm) mesh. If the free area through a design of louver or grille is known, it should be used in calculating the size opening required to provide the free area specified. If the design and free area is not known, it may be assumed that wood louvers will be 20-25 percent free area and metal louvers and grilles will have 60-75 percent free area. Louvers and grilles shall be fixed in the open position or interlocked with the equipment so that they are opened automatically during equipment operation.

Special Conditions Created by Mechanical Exhausting or Fireplaces: operation of exhaust fans, ventilation systems, clothes dryers or fireplaces may create conditions requiring special attention to avoid unsatisfactory operation of installed gas utilization equipment.

HOTTER WATER CAN SCALD:

Water heaters are intended to produce hot water. Water heated to a temperature which will satisfy clothes washing, dish washing, cleaning and other sanitizing needs can scald and permanently injure you upon contact. Some people are more likely to be permanently injured by hot water than others. These include the elderly, children, the infirm, or physically/ mentally handicapped. If anyone using hot water in your home fits into one of these groups or if there is a local code or province law requiring a certain temperature water at the hot water tap, then you must take special precautions. In addition to using the lowest possible temperature setting that satisfies your hot water needs, a means such as a *mixing valve, shall be used at the hot water taps used by these people or at the water heater. Mixing valves are available at plumbing supply or hardware stores, see Figure 8 on page 9 and Figure 15 below. Valves for reducing point of use temperature by mixing cold and hot water are also available. Consult Maytag Customer Service (1-800-788-8899). Follow manufacturer’s instructions for installation of the valves. Before changing the factory setting on the thermostat, read the Temperature Regulation section in this manual.

FIGURE 15.

This water heater shall not be connected to any heating systems or component(s) used with a non-potable water heating appliance.

13

Image 13
Contents Series Nine Important Definitions Safe INSTALLATION, USE and ServiceSafety Precautions Table of Contents Customer Responsibilities Product SpecificationsAccessories Accessories and Tools NeededAdditional Tools Needed When Sweat Soldering ToolsRemoving the Old Water Heater Preparations for InstallationGET to Know Your Water Heater GAS Models Typical InstallationMixing Valve Usage Facts to Consider About the Location Locating and Installing the NEW Water HeaterInsulation Blankets ALL AIR from Inside Buildings See Figures 10 Water Piping Temperature-Pressure Relief Valve Filling the Water Heater Venting Gas Piping Sediment Traps GAS Piping with Flexible ConnectorOperating Instructions For Your Safety Read Before Lighting Temperature Time to Produce 2nd & 3rd Temperature RegulationTank Sediment Cleaning Service and MaintenanceBurner Cleaning Vent System InspectionHousekeeping Temperature-Pressure Relief Valve OperationAnode Rod Inspection DrainingDrain Valve Washer Replacement TroubleshootingService Start Up ConditionsSmoke / Odor Operational ConditionsLeakage Checkpoints Problem Cause Solution Troubleshooting GuideMaytag GAS Water Heaters Repair Parts ListPage Page Page Warranty Series Nine Avertissement INSTALLATION, Utilisation ET Entretien SécuritairesMesures DE Sécurité Table DES Matières Choix DE L’EMPLACEMENT DU CHAUFFE-EAU ET InstallationSpécifications Techniques DU Produit Responsabilité DU ClientAccessoires Accessoires ET Outils NécessairesOutils Outils supplémentaires requis pour la soudure à l’étainEnlèvement de l’ancien chauffe-eau Préparation À L’INSTALLATIONDescription DU CHAUFFE-EAU AU GAZ Installation TypeUtilisation D’UN Robinet Mélangeur Points à considérer dans le choix de l’emplacement Choix DE L’EMPLACEMENT DU CHAUFFE-EAU ET InstallationRevêtements isolants Air de combustion et air de ventilation en espace clos Air de combustion et air de ventilation en espace ouvertTuyauterie d’eau Soupape de décharge à sécurité thermique Remplissage du chauffe-eau Ventilation Tuyauterie de gaz Tuyauterie DE Gazavec Raccord Flexible Collecteur d’impuretésPage Pour Votre Sécurité Lisez Avant D’ALLUMER Réglage de la température Nettoyage du réservoir dépôts Entretien ET RéparationInspection du système de ventilation Inspection du brûleurInspection de la tige d’anode Entretien courantVidange Situations pouvant se produire à la mise en service Remplacement de la rondelle du robinet de vidangeGuide DE Dépannage Fumée et odeur Conditions de fonctionnementPoints de vérification des fuites Problème Cause Solution CHAUFFE-EAU AU GAZ Maytag Liste DES Pièces DE RechangePage Page Page Garantie

HXN4975S specifications

The Maytag HXN4975S is a state-of-the-art refrigerator that perfectly balances innovation, style, and functionality. Designed for modern kitchens, this model stands out with its stainless steel finish, which not only adds a sleek aesthetic but also ensures durability and resistance to fingerprints and smudges.

One of the standout features of the HXN4975S is its generous storage capacity. With multiple shelves and adjustable compartments, it provides ample space for groceries of all sizes. The fridge section includes spill-proof glass shelves that are easy to clean and prevent spills from cascading down to lower shelves, maintaining cleanliness effortlessly. Enhanced storage options like gallon door bins and humidity-controlled crisper drawers make it easy to store and organize a variety of items.

The HXN4975S is equipped with advanced cooling technologies. Its dual cooling system ensures optimal temperature and humidity levels, keeping your food fresh longer. This technology separates the airflow between the refrigerator and freezer, preventing the transfer of odors and maintaining the quality of stored food. Additionally, the refrigerator incorporates a powerful compressor that efficiently maintains the desired temperatures while reducing energy consumption.

Another key feature of the Maytag HXN4975S is its smart connectivity. With built-in Wi-Fi, users can control their refrigerator remotely through a compatible smartphone app. This feature allows for adjustments to be made on-the-go, enabling users to monitor temperatures, receive alerts, and even diagnose issues without the need for a technician.

Energy efficiency is also a priority for the HXN4975S, as it is ENERGY STAR rated. This ensures that the refrigerator not only saves on energy bills but also contributes to a greener environment. The LED lighting inside the unit provides bright illumination while consuming minimal energy, allowing for excellent visibility regardless of the time of day.

The Maytag HXN4975S also focuses on user-friendly features, such as its intuitive temperature control and ice and water dispenser located conveniently on the front door. The sleek design incorporates a filtered water system, providing clean and safe drinking water instantly.

Overall, the Maytag HXN4975S embodies a commitment to quality and efficiency, catering to the needs of busy families while enhancing the kitchen's functionality and style. This refrigerator truly stands out as a reliable appliance designed with both performance and user experience in mind.