Diagnostics and Troubleshooting
Calibration Troubleshooting
This section describes the problems that you may occasionally have when using the KODAK Device Calibration Software or the Calibration Software for the KODAK PROFESSIONAL LED II Printer. It also identifies the probable causes for these problems and provides solutions for correcting these problems.
Calibration Graph
The graph below is an indication that the calibration performed was out of tolerance.
This may be result from invalid densitometer readings. It is necessary to perform another calibration cycle if you see a graph that looks like the one above.
Numbered Error Messages
Error | Error Code /Status | Possible Cause/Subsystem | Possible Solution | |
Code | Message | |||
|
| |||
|
|
|
| |
1 | The following file is | The system is trying to access a | Close any other applications that | |
| locked:_filename_. | file that is currently in use. | may be accessing the file. | |
|
|
|
| |
2 | The following file is | The system is trying to access a | Change the protections on the file | |
| protected:_filename_. | file that is protected. | to grant access to the user. | |
|
|
|
| |
3 | The following file was not | The system was trying to access | Verify that the filename on one of | |
| found:_filename_. | a file that it could not find. | the configuration dialog windows is | |
|
|
| correct. | |
|
|
|
| |
4 | Error:_oserror_occurred | An operating system error | • Rerun the application. | |
| during operation:_operation_ | occurred. | • Reboot the operating system | |
| on file:_filename_. |
|
| |
|
|
|
| |
5 | The following file is in an | The file does not conform to the | Verify the file format. | |
| incorrect format:_filename_. | application specification. |
| |
|
|
|
|
September 2000 |