Kodak 20R manual Diagnostics and Troubleshooting, on device devicename, device:_devicename_

Models: 20R

1 166
Download 166 pages 44.37 Kb
Page 86
Image 86
on device:_devicename_.

Diagnostics and Troubleshooting

 

Error

Error Code /Status

Possible Cause/Subsystem

Possible Solution

 

Code

Message

 

 

 

 

 

 

 

 

 

111

There is insufficient memory

The application does not have

Close the other applications and

 

 

for the requested operation

enough memory to complete the

unnecessary windows.

 

 

on device:_devicename_.

operation.

 

 

 

 

 

 

 

112

A communications time-out

The connection between the

Check that all of the cables are

 

 

occurred during operation on

printer and host computer was

properly connected.

 

 

device:_devicename_.

lost.

 

 

 

 

 

 

 

113

A device driver for the

The application could not find the

Make sure that the Calibration

 

 

following device could not be

necessary device software to

Application and ASPI SCSI device

 

 

found:_devicename_.

communicate with the printer.

driver are installed correctly.

 

 

 

 

 

 

114

An error occurred during

• The cable between the printer

• Check that all of the cables are

 

 

communications to the

and the host computer is worn.

properly connected.

 

 

following device:

• One or more of the

• Check the cables and

 

 

_devicename_.

connections between the

connections between the printer

 

 

 

printer and the host computer

and the host computer for wear

 

 

 

has malfunctioned.

and if necessary, replace them.

 

 

 

 

 

 

115

An operation error occurred

• The cable between the printer

• Check that all of the cables are

 

 

during communications to

and the host computer is worn.

properly connected.

 

 

the following device:_

• One or more of the

• Check the cables and

 

 

devicename_.

connections between the

connections between the printer

 

 

 

printer and the host computer

and the host computer for wear

 

 

 

has malfunctioned.

and if necessary, replace them.

 

 

 

 

 

 

116

A software warning has been

A software error has occurred on

Resolve printer error condition.

 

 

issued by the following

the printer.

 

 

 

device: _devicename_ Error

 

 

 

 

Message: _errmsg_

 

 

 

 

 

 

 

 

117

A software error has been

An error has occurred on the

Resolve printer error condition.

 

 

detected by the following

printer.

 

 

 

device: _devicename_ Error

 

 

 

 

Message: _errmsg_

 

 

 

 

 

 

 

 

118

A SCSI ID for the following

SCSI driver not found.

Reinstall SCSI driver on host

 

 

device was not found:

 

computer.

 

 

_devicename_.

 

 

 

 

 

 

 

 

119

The wrong SCSI ID was

SCSI ID is incorrect.

Set Target SCSI ID to printer SCSI

 

 

specified for the following

 

ID.

 

 

device: _devicename_.

 

 

 

 

 

 

 

 

120

This device has been setup

Device chosen has not been

Verify device chosen matches the

 

 

for the wrong model of

found.

printer model.

 

 

printer: _devicename_.

 

 

 

 

 

 

 

 

121

Unable to read STATUS from

Unable to see the printer.

Check SCSI cable connections.

 

 

device: _devicename_.

 

 

 

 

 

 

 

 

122

The selected LUT contains

Trying to send a 12-bit LUT to a

Select a 10-bit LUT file.

 

 

data that exceeds the limits

10-bit printer.

 

 

 

of this printer.

 

 

 

 

 

 

 

 

201

An error occurred while

The system is trying to allocate

Close any unnecessary

 

 

trying to allocate memory.

memory, however, no memory is

applications.

 

 

 

available.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5-16

September 2000

Page 86
Image 86
Kodak 20R manual Diagnostics and Troubleshooting, on device devicename, device:_devicename_, found:_devicename_