Maytag HRX40HART, HRX50YART, HRX40YQRT, HRX40YARS, HRX40YART, HRX40HARS, HRX40HQRT manual Venting

Page 16

the right (clockwise). The drain valve is on the lower front of the water heater.

Open the cold water supply valve to the water heater.

NOTE: The cold water supply valve must be left open when the water heater is in use.

To insure complete filling of the tank, allow air to exit by opening the nearest hot water faucet. Allow water to run until a constant flow is obtained. This will let air out of the water heater and the piping.

Check all water piping and connections for leaks. Repair as needed.

Venting

VENT DAMPERS - Any vent damper, whether it is operated thermally or otherwise must be removed if its use inhibits proper drafting of the water heater.

Thermally Operated Vent Dampers: Gas-fired water heaters having thermal efficiency in excess of 80% may produce a relatively low flue gas temperature. Such temperatures may not be high enough to properly open thermally operated vent dampers. This would cause spillage of the flue gases and may cause carbon monoxide poisoning.

Vent dampers must bear evidence of certification as complying with the current edition of the American National Standard ANSI Z21.68 (ANSI Z21.66 & 67, respectively, cover electrically and mechanically actuated vent dampers). Before installation of any vent damper, consult your Maytag Customer Service Center or the local gas supplier for further information.

Specialist at 1-800-365-0024or gas supplier to aid you in determining the proper venting for your water heater from the vent tables in the current edition of the National Fuel Gas Code ANSI Z223.1/NFPA 54.

Periodically check the venting system for signs of obstruction or deterioration and replace if needed.

The combustion and ventilation air flow must not be obstructed.

The water heater with draft hood installed must be connected to a chimney or listed vent pipe system, which terminates to the outdoors. Never operate the water heater unless it is vented to the outdoors and has adequate air supply to avoid risks of improper operation, explosion or asphyxiation.

For proper draft hood attachment, the draft hood legs may be angled slightly inward.

Place the draft hood legs in the receiving holes on the top of the water heater. The legs will snap in the holes to give a tight fit. Secure two legs to top with sheet metal screws.

Place the vent pipe over the draft hood. With the vent pipe in position, drill a small hole through both the vent pipe and draft hood. Secure them together with a sheet metal screw, see Figure 18.

Obstructed or deteriorated vent systems may present serious health risk or asphyxiation.

To insure proper venting of this gas-fired water heater, the correct vent pipe diameter must be utilized. Any additions or deletions of other gas appliances on a common vent with this water heater may adversely affect the operation of the water heater. Consult a Maytag Service Specialist at 1-800-365-0024 or gas supplier if any such changes are planned.

For proper venting in certain installations, a larger diameter vent pipe may be necessary. Consult a Maytag Service

FIGURE18.

The vent pipe from the water heater must be no less than the diameter of the draft hood outlet on the water heater and must slope upward at least 1/4 inch per linear foot (21 mm per meter), see Figure 19.

FIGURE19.

All vent gases must be completely vented to the outdoors of the structure (dwelling). Install only the draft hood provided with the new water heater and no other draft hood.

Vent pipes must be secured at each joint with sheet metal screws.

16

Image 16
Contents HRX40HARS HRX50HART HRX50YQRT5HRX40HART HRX50HQRT5 HRX40YQRT HRX50YQRT HRX40HQRT HRX40YARS HRX50YARTSafe INSTALLATION, USE and Service Important DefinitionsSafety Precautions Table of Contents To Install or Operate the Water Heater Product SpecificationsCustomer Responsibilities Accessories and Tools Needed AccessoriesAdditional Tools Needed When Sweat Soldering ToolsInstructions for Installation Removing the Old Water HeaterTypical Installation ThermostatPilot & Main Burner Thermostat Shield OptionalMixing Valve Usage Locating the NEW Water Heater Facts to Consider About the LocationInsulation Blankets ALL AIR from Inside Buildings Water Piping Temperature-Pressure Relief Valve Valve and Pipe InsulationFilling the Water Heater Venting Gas Piping GAS Piping with Flexible Connector Sediment TrapsOperating Instructions What to do if YOU Smell GASTOP Knob GAS ControlTemperature Regulation Temperature Time to Produce 2nd & 3rdService and Maintenance Tank Sediment CleaningBurner Cleaning Vent System InspectionTemperature-Pressure Relief Valve Operation HousekeepingAnode Rod Inspection DrainingTroubleshooting Drain Valve Washer ReplacementService Start Up ConditionsOperational Conditions Smoke / OdorHigh Temperature Shut-Off System Leakage CheckpointsTroubleshooting Guide Repair Parts List Burner Assembly Pilot AssemblyThis is a Repair Parts LIST, not a Packing List HRX40HARSBurnerassembly Pilotassembly HRX50YART HRX50HART HRX50YQRT5 HRX50HQRT5STATE/MAYTAG Part Number Conversion KEY Page Page Warranty