CUSTOMER RESPONSIBILITIES

Thank You for purchasing a Maytag water heater. Properly installed and maintained, it should give you years of trouble free service. It is strongly suggested that this new water heater be professionally installed, contact a Maytag Service Specialist at 1-800-365-0024 for recommended installers.

Abbreviations Found In This Instruction Manual:

CSA - Canadian Standards Association

ANSI - American National Standards Institute

NFPA - National Fire Protection Association

ASME - American Society of Mechanical Engineers

GAMA - Gas Appliance Manufacturers Association

This gas-fired water heater is design certified by CSA INTERNATIONAL under American National Standard/CSA Standard for Gas Water Heaters ANSI Z21.10.1 • CSA 4.1 (current edition).

Read the “Safety Precautions” section, page 3 of this manual first and then the entire manual carefully. If you don’t follow the safety rules, the water heater will not operate properly. It could cause DEATH, SERIOUS BODILY INJURY AND/OR PROPERTY DAMAGE.

This manual contains instructions for the installation, operation, and maintenance of the gas-fired water heater. It also contains warnings through out the manual that you must read and be aware of. All warnings and all instructions are essential to the proper operation of the water heater and your safety. Since we cannot put everything on the first few pages, READ THE ENTIRE MANUAL BEFORE ATTEMPTING

TO INSTALL OR OPERATE THE WATER HEATER.

The installation must conform with these instructions and the local code authority having jurisdiction. In the absence of

local codes, installations shall comply with the following:

In the United States: The National Fuel Gas Code ANSI Z223.1/NFPA 54. This publication is available from the Canadian Standards Association, 8501 East Pleasant Valley Rd., Cleveland Ohio 44131, or The National Fire Protection Association, 1 Batterymarch Park, Quincy, MA 02269.

If after reading this manual you have any questions or do not understand any portion of the instructions, call a Maytag

Service Specialist at 1-800-365-0024 for an authorized servicer.

Carefully plan the place where you are going to put the water heater. Correct combustion, vent action, and vent pipe installation are very important in preventing death from possible carbon monoxide poisoning and fires, see figure 1 and 2.

Examine the location to ensure the water heater complies with the Facts to Consider About the Location section in this manual.

For California installation this water heater must be braced, anchored, or strapped to avoid falling or moving during an earthquake. See instructions for correct installation procedures. Instructions may be obtained from your local dealer, wholesaler, public utilities or California Office of the State Architect, 400 P Street, Sacramento, CA 95814.

Massachusetts Code requires this water heater to be installed in accordance with Massachusetts 248-CMR 2.00: State Plumbing Code and 248-CMR 5.00.

Complies with SCAQMD rule #1121 and districts having equivalent NOx requirements.

PRODUCT SPECIFICATIONS

 

TANK

 

 

RECOVERY

MINIMUM

 

DIMENSIONS

 

CAPACITY

TYPE

 

RATE GALS.

VENT PIPE

DIAMETER

IN INCHES (mm)

 

IN GALS

OF

BTU

PERHOUR

INCHES

INCHES

HEIGHT TOP OF

MODELNUMBER

(LTRS)

GAS

RATE

@ 90°F RISE

(mm)

(mm)

DRAFTHOOD

HRX40YARS

40 (151)

NATURAL

40,000

41.0

3” (76) or 4” (102)

20” (508)

51 5/8” (1,311)

HRX40HARS

40 (151)

PROPANE

37,000

41.0

3” (76) or 4” (102)

20” (508)

51 5/8” (1,311)

HRX40YART

38 (144)

NATURAL

40,000

39.0

3” (76) or 4” (102)

18 1/2” (470)

57 5/8” (1,464)

HRX40HART

38 (144)

PROPANE

37,000

39.0

3” (76) or 4” (102)

18 1/2” (470)

57 5/8” (1,464)

HRX40YQRT

38 (144)

NATURAL

50,000

48.0

4” (102)

20 1/4” (514)

58 1/2” (1,486)

HRX40HQRT

38 (144)

PROPANE

47,000

48.0

4” (102)

20 1/4” (514)

58 1/2” (1,486)

HRX50YART

50 (189)

NATURAL

40,000

41.0

3” (76) or 4” (102)

20 1/4” (514)

60 7/8” (1,546)

HRX50HART

50 (189)

PROPANE

37,000

39.0

3” (76) or 4” (102)

20 1/4” (514)

60 7/8” (1,546)

HRX50YQRT5

50 (189)

NATURAL

65,000

67.0

4” (102)

22” (559)

65” (1,651)

HRX50HQRT5

50 (189)

PROPANE

55,000

57.0

4” (102)

22” (559)

65” (1,651)

HRX50YQRT

48 (182)

NATURAL

50,000

51.0

4” (102)

20 1/4" (514)

60 7/8” (1,546)

HRX50HQRT

48 (182)

PROPANE

45,000

51.0

4” (102)

20 1/4" (514)

60 7/8” (1,546)

* Adding suffix “D” denotes high altitude. High altitude models have a B.T.U./Recovery Rate 10% less than shown.

5

Image 5
Contents HRX50YQRT5 HRX40HARS HRX50HARTHRX40HART HRX50HQRT5 HRX40YQRT HRX50YQRT HRX40HQRT HRX40YARS HRX50YARTImportant Definitions Safe INSTALLATION, USE and ServiceSafety Precautions Table of Contents Customer Responsibilities Product SpecificationsTo Install or Operate the Water Heater Accessories Accessories and Tools NeededAdditional Tools Needed When Sweat Soldering ToolsRemoving the Old Water Heater Instructions for InstallationThermostat Typical InstallationPilot & Main Burner Thermostat Shield OptionalMixing Valve Usage Facts to Consider About the Location Locating the NEW Water HeaterInsulation Blankets ALL AIR from Inside Buildings Water Piping Valve and Pipe Insulation Temperature-Pressure Relief ValveFilling the Water Heater Venting Gas Piping Sediment Traps GAS Piping with Flexible ConnectorWhat to do if YOU Smell GAS Operating InstructionsTOP Knob GAS ControlTemperature Time to Produce 2nd & 3rd Temperature RegulationTank Sediment Cleaning Service and MaintenanceBurner Cleaning Vent System InspectionHousekeeping Temperature-Pressure Relief Valve OperationAnode Rod Inspection DrainingDrain Valve Washer Replacement TroubleshootingService Start Up ConditionsSmoke / Odor Operational ConditionsLeakage Checkpoints High Temperature Shut-Off SystemTroubleshooting Guide Burner Assembly Pilot Assembly Repair Parts ListThis is a Repair Parts LIST, not a Packing List HRX40HARSHRX50YART HRX50HART HRX50YQRT5 HRX50HQRT5 Burnerassembly PilotassemblySTATE/MAYTAG Part Number Conversion KEY Page Page Warranty