There must be a minimum of 6 inches (153 mm) clearance between single wall vent pipe and any combustible material. Fill and seal any clearance between single wall vent pipe and combustible material with mortar mix, cement, or other noncombustible substance. For other than single wall, follow vent pipe manufacturer’s clearance specifications. To insure a tight fit of the vent pipe in a brick chimney, seal around the vent pipe with mortar mix cement.

Failure to have required clearances between vent piping and combustible material will result in a fire hazard.

Be sure vent pipe is properly connected to prevent escape of dangerous flue gases which could cause deadly asphyxiation.

Chemical vapor corrosion of the flue and vent system may occur if air for combustion contains certain chemical vapors. Spray can propellants, cleaning solvents, refrigerator and air conditioner refrigerants, swimming pool chemicals, calcium and sodium chloride, waxes, bleach and process chemicals are typical compounds which are potentially corrosive.

Gas Piping

Make sure the gas supplied is the same type listed on the model rating plate. The inlet gas pressure must not exceed 14 inch water column (2.6kPa) for natural and propane gas (L.P.) gas. The minimum inlet gas pressure listed on the rating

plate is for the purpose of input adjustment. If the gas control valve is subjected to pressures exceeding 1/2 pound per square inch (3.5kPa), the damage to the gas control valve could result in a fire or explosion from leaking gas.

If the main gas line Shut-off serving all gas appliances is used, also turn “OFF” the gas at each appliance. Leave all gas appliances shut “OFF” until the water heater installation is complete.

A gas line of sufficient size must be run to the water heater. Consult the current edition of National Fuel Gas Code ANSI Z223.1/NFPA 54 and your gas supplier concerning pipe size.

There must be:

A readily accessible manual shut off valve in the gas supply line serving the water heater, and

A drip leg (sediment trap) ahead of the gas control valve to help prevent dirt and foreign materials from entering the gas control valve.

A flexible gas connector or a ground joint union between the shut off valve and control valve to permit servicing of the unit.

Be sure to check all the gas piping for leaks before lighting the water heater. Use a soapy water solution, not a match or open flame. Rinse off soapy solution and wipe dry.

The minimum inlet gas pressure shown on the rating plate is that which will permit firing at the rated input.

If a standard model is installed above 3,300 feet (1,006 m) or a high altitude model is installed above 5,500 feet (1,676 m) the input rating should be reduced at the rate of 4 percent for each 1,000 feet (305 m ) above sea level which requires replacement of the burner orifice in accordance with National Fuel Gas Code ANSI Z223.1/NFPA 54. Contact a Maytag Service Specialist at 1-800-365-0024 or your local gas supplier or call for further information.

Failure to replace the standard orifice with a high altitude orifice when installed at elevations above 3,300 feet (1,006 m) or above 5,500 feet (1,676 m) for high altitude model could result in improper and inefficient operation of the appliance, producing carbon monoxide gas in excess of safe limits, which could result in serious injury or death. Contact a Maytag Service

Specialist at 1-800-365-0024or your local gas supplier for any specific changes which may be required in your area.

17

Image 17
Contents HRX50YQRT5 HRX40HARS HRX50HARTHRX40HART HRX50HQRT5 HRX40YQRT HRX50YQRT HRX40HQRT HRX40YARS HRX50YARTImportant Definitions Safe INSTALLATION, USE and ServiceSafety Precautions Table of Contents Customer Responsibilities Product SpecificationsTo Install or Operate the Water Heater Accessories Accessories and Tools NeededAdditional Tools Needed When Sweat Soldering ToolsRemoving the Old Water Heater Instructions for InstallationThermostat Typical InstallationPilot & Main Burner Thermostat Shield OptionalMixing Valve Usage Facts to Consider About the Location Locating the NEW Water HeaterInsulation Blankets ALL AIR from Inside Buildings Water Piping Valve and Pipe Insulation Temperature-Pressure Relief ValveFilling the Water Heater Venting Gas Piping Sediment Traps GAS Piping with Flexible ConnectorWhat to do if YOU Smell GAS Operating InstructionsTOP Knob GAS ControlTemperature Time to Produce 2nd & 3rd Temperature RegulationTank Sediment Cleaning Service and MaintenanceBurner Cleaning Vent System InspectionHousekeeping Temperature-Pressure Relief Valve OperationAnode Rod Inspection DrainingDrain Valve Washer Replacement TroubleshootingService Start Up ConditionsSmoke / Odor Operational ConditionsLeakage Checkpoints High Temperature Shut-Off SystemTroubleshooting Guide Burner Assembly Pilot Assembly Repair Parts ListThis is a Repair Parts LIST, not a Packing List HRX40HARSHRX50YART HRX50HART HRX50YQRT5 HRX50HQRT5 Burnerassembly PilotassemblySTATE/MAYTAG Part Number Conversion KEY Page Page Warranty