OPERATING INSTRUCTIONS

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

BEFORE OPERATING: ENTIRE SYSTEM MUST BE FILLED WITH WATER AND AIR PURGED FROM ALL LINES.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS:

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician . Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately contact a qualified installer or service agency to replace the flooded water heater. Do not attempt to repair the unit! It must be replaced!

LIGHTING INSTRUCTIONS

 

TOP KNOB

GAS CONTROL

FIGURE “D”

1.STOP! Read the safety information above on this label.

2.Set the thermostat to lowest setting (PILOT LIGHTING).

Turn thermostat dial fully clockwise until it stops.

3.Push the gas control knob down slightly and turn clockwise

to “OFF”, SEE FIGURE “A”.

NOTE: Knob CANNOT be turned from “PILOT” to “OFF” unless it is pushed down slightly. Do not force.

4.Remove the outer burner door located below the gas control.

5.Wait five (5) minutes to clear out any gas. If you then

smell gas, STOP! Follow “B” in the safety information above on this label. If you don’t smell gas, go to next step.

6.This unit is equipped with a push button pilot igniter, which is used to light the pilot. Locate the igniter on the gas control.

7.Turn gas control knob counterclockwise to “PILOT”, SEEFIGURE “B”.

8.The pilot is located on the right side of the burner. It can be located by looking through the glass view port while pressing the piezo igniter button several times. Look for a spark at the pilot location, FIGURE “D”.

9.Once the pilot has been found, push the gas knob all the way down. Immediately press the pilot igniter button rapidly

(4)to (5) times. If the pilot will not light, repeat step (3) through (9).

10.Continue to hold the gas control knob down for about one

(1)minute after the pilot is lit. Release the gas control knob and it will pop back up. Pilot should remain lit. If it goes out, repeat step (3) through (9). It may take several minutes for air to clear the lines before the pilot will light.

If knob does not pop up when released, stop and immediately call your service technician or gas supplier.

If the pilot will not stay lit after several tries, turn the gas control knob clockwise to “OFF” and call your service

technician or gas supplier. SEE FIGURE “A”.

11.Once the pilot flame is established replace the outer burner door.

12.At arms length away, turn gas control knob

counterclockwise to “ON”. SEE FIGURE “C”.

13.Set thermostat to desired setting.

DANGER: Hotter water increases the risk of scald injury. Consult the instruction manual before changing temperature.

TO TURN OFF GAS TO APPLIANCE

1. Set thermostat to the lowest setting (PILOT LIGHTING).

2. Push gas control knob down slightly and turn clockwise

to “OFF”. Do not force. SEE FIGURE “A”.

 

19

Image 19
Contents HRX40YARS HRX50YART HRX40HARS HRX50HARTHRX50YQRT5 HRX40HART HRX50HQRT5 HRX40YQRT HRX50YQRT HRX40HQRTImportant Definitions Safe INSTALLATION, USE and ServiceSafety Precautions Table of Contents To Install or Operate the Water Heater Product SpecificationsCustomer Responsibilities Tools Accessories and Tools NeededAccessories Additional Tools Needed When Sweat SolderingRemoving the Old Water Heater Instructions for InstallationThermostat Shield Optional Typical InstallationThermostat Pilot & Main BurnerMixing Valve Usage Facts to Consider About the Location Locating the NEW Water HeaterInsulation Blankets ALL AIR from Inside Buildings Water Piping Valve and Pipe Insulation Temperature-Pressure Relief ValveFilling the Water Heater Venting Gas Piping Sediment Traps GAS Piping with Flexible ConnectorGAS Control Operating InstructionsWhat to do if YOU Smell GAS TOP KnobTemperature Time to Produce 2nd & 3rd Temperature RegulationVent System Inspection Service and MaintenanceTank Sediment Cleaning Burner CleaningDraining Temperature-Pressure Relief Valve OperationHousekeeping Anode Rod InspectionStart Up Conditions TroubleshootingDrain Valve Washer Replacement ServiceSmoke / Odor Operational ConditionsLeakage Checkpoints High Temperature Shut-Off SystemTroubleshooting Guide HRX40HARS Repair Parts ListBurner Assembly Pilot Assembly This is a Repair Parts LIST, not a Packing ListHRX50YART HRX50HART HRX50YQRT5 HRX50HQRT5 Burnerassembly PilotassemblySTATE/MAYTAG Part Number Conversion KEY Page Page Warranty