Optima Company 600 - 1700 manual Control unit Rego, Automatic defrosting

Page 10

Control unit

Control unit Rego 800

The control unit makes sure the heat pump gives the best energy savings and that it runs for many years. The control unit controls and monitors the heating and hot water supply in your house. The monitoring function is es- pecially important, it shuts down the heat pump in the event of operational disturbances so that no critical parts are damaged.

Additional heat gives more output

Additional heating is required when the heat pump is unable to meet the heating requirements or when it has stopped due to an outdoor temperature that is too low. The additional heat is provided by an electric cassette, existing electric/oil-fired boiler or electric boiler 290 A/W (Optima 600- 1100). Note that when the heat pump is running, the additional heat source only supplies the power that the heat pump cannot produce. When the heat pump is once more able to meet the heating demand, the additional heat is automatically switched off.

Hot water is given priority over heating water

In a house with water based heating a difference is made between heating water and hot water. The heating water is for radiators and underfloor coils and hot water is for showers and taps.

When electric boiler 290 A/W is included, hot water is heated in the electric boiler’s hot water heater. When the electric cassette or existing electric/oil- fired boiler is included, an external hot water heater can be connected.

In both cases, there must be a sensor, which detects the temperature of the hot water. The heating water passes through the hot water cylinder’s outer shell and heats up the hot water heater’s inner tank. The control unit makes sure the heating of hot water is given priority over the heating of the heating water.

Hot water

Heating water

Automatic defrosting

Ice may form on the evaporator at outdoor temperatures below +10ºC. When ice forms to an extent that it obstructs the air flow through the evapo- rator automatic defrosting starts. Defrosting is controlled by a four-way valve. The valve reverses the flow of the refrigerant in the circuit so that the hot gas melts the ice on the evaporator fins. See Refrigerant flow in defrost mode in the figure under the heading How a heat pump works.

There is also a fan defrost function, which means that hot air blows upwards through the fan to prevent it freezing solid.

10

Image 10
Contents IVT Optima Page Page Innehåll For the user Important informationTechnology in and around the heat pump How a heat pump worksHeat pump collects heat from the outdoor air How a heat pump works Component parts of the heat pump IVT OptimaComponent parts of the heat pump Additional heat gives more output Control unit RegoAutomatic defrosting Hot water is given priority over heating waterHeat pump with electric boiler 290 A/W Control unit’s operating modesHeat pump with electric cassette OptimaControl with an outdoor sensor Control with an outdoor sensor and a room sensorStatus lamp Control panel290 A/W Control cabinet Symbol overview Power switch ON/OFFHow to use the control panel Menu dialMenu Menu levelsMenu overview Set the heating Setting the heating, room sensor not installedSetting the heating, room sensor installed Extra hot waterOutdoor sensor T2 TemperaturesFlow sensor T1 Hot water sensor T3Advanced menu OverviewAdjusting a single value Flow temperatureOutdoor temperature Heat curveSet the heat curve Hysteresis Set the desired room temperatureTime limited settings Time controlHeating, maximum operating time at hot water requirement Heating seasonHoliday Extra hot water Hot water settingsRecurring increase in the hot water temperature Hot water peakTimers Setting the clockReturn to factory settings Alarm logAccess level Deactivate alarm buzzerRemove dirt and leaves MaintenanceUnscrew the protective covers Protective coversEvaporator Particle filterSnow and ice Dimmed menu display What to do if a fault occursExample of an alarm Emergency operationTripped low pressure switch All alarms and warning windowsList of all alarms List of all warning windowsTripped high pressure switch Sensor failure / short circuitT6 High hot gas temperature Faulty function in 4-way valveT8 High flow temperature Possible cause 4 Compressor error Low temperature in condenserPossible cause 3 Faulty heat carrier pump Tripped motor cut-out compressorPossible cause 2 The hot water temperature is set too high High temperature difference heat transfer fluidPossible cause 4 Faulty fan motor Tripped motor cut-out fan Optima1000/1300Action Open the valves Factory settings Technical informationTechnical information Sound levelsTemperature ºC Sensor table

600 - 1700 specifications

The Optima Company 600 - 1700 is a sophisticated product line designed to meet the demanding needs of modern industrial applications. Recognized for its efficiency and versatility, the Optima 600 - 1700 series has gained traction across various sectors, including manufacturing, chemical processing, and energy production.

At its core, the Optima 600 - 1700 combines cutting-edge technology with user-friendly features. One of the standout characteristics of this series is its advanced control system. The intuitive interface allows operators to easily configure settings, monitor performance, and receive real-time updates on system conditions. This feature not only enhances user experience but also maximizes operational efficiency by minimizing downtime.

A notable aspect of the Optima series is its modular design, which offers a high degree of customization. Businesses can choose from various configurations and components that best suit their specific operational needs. This adaptability means that the Optima 600 - 1700 can be scaled up or down, making it ideal for both small-scale operations and large production facilities.

The durability of the Optima 600 - 1700 is another key feature. Designed to withstand harsh industrial environments, the materials used in its construction ensure longevity and reliability. Manufacturers have prioritized robust engineering, resulting in a product that requires minimal maintenance while consistently delivering optimal performance.

Energy efficiency is a critical focus for the Optima Company, and the 600 - 1700 series exemplifies this commitment. The equipment is designed to minimize energy consumption without sacrificing functionality. This not only reduces operational costs for businesses but also aligns with global sustainability goals.

Further enhancing its capabilities, the Optima 600 - 1700 series incorporates smart technology features. With integrated IoT functionalities, clients can benefit from predictive maintenance, enabling them to anticipate potential issues before they escalate. This proactive approach to maintenance leads to increased uptime and can result in substantial cost savings over the lifespan of the equipment.

In summary, the Optima Company 600 - 1700 series stands out as a remarkable solution in the industrial equipment market. With its combination of advanced technology, customization options, durability, energy efficiency, and smart features, it meets the evolving demands of businesses while ensuring reliability and performance. Manufacturers and industrial operators looking for an advanced yet practical solution would do well to consider the Optima 600 - 1700 series as a key asset in their operational arsenal.