Optima Company 600 - 1700 manual Hot water settings, Extra hot water, Hot water peak

Page 23

Hot water settings

The menus for hot water settings are only displayed when a hot water heater is installed.

Extra hot water

You can obtain extra hot water by temporarily increasing the temperature of the water in the hot water cylinder. A higher water temperature gives more hot water when, for example, several people wish to shower. The heat pump uses additional heat to increase the temperature to the desired value, see point 5. The function Extra hot water (number of hours) is also available under Menu.

This is what to do:

1.Select Hot water in the advanced menu.

2.Select Extra hot water.

3.Set the number of hours that the function is to be active.

4.Select Save to save the change or Cancel to return without saving.

5.Set the desired Stop temperature.

6.Select Save to save the change or Cancel to return without saving. Read off the remaining time of Extra hot water by going toTimers.

Advanced menu

Note

When the set time has elapsed you must repeat the setting to get extra hot water again. You can also increase the number of hours during an ongoing Extra hot water period.

Hot water peak

Recurring increase in the hot water temperature

The Hot water peak menu is used to set the interval for a recurring increase in the hot water temperature. If, for example, you set the value seven days, the temperature is increased once a week to approximately 65ºC. You can also specify Start time for when the temperature increase is to start, factory setting is 03:00.

Time control hot water

The Time control hot water function means that you can choose to com- pletely disable hot water heating to save energy. This is primarily effective when peak tariffs are charged. This is done in the same way as other heat pump time controls.

Note

Time control hot water can impair hot water production.

23

Image 23
Contents IVT Optima Page Page Innehåll Important information For the userHeat pump collects heat from the outdoor air How a heat pump worksTechnology in and around the heat pump How a heat pump works IVT Optima Component parts of the heat pumpComponent parts of the heat pump Hot water is given priority over heating water Control unit RegoAutomatic defrosting Additional heat gives more outputOptima Control unit’s operating modesHeat pump with electric cassette Heat pump with electric boiler 290 A/WControl with an outdoor sensor and a room sensor Control with an outdoor sensor290 A/W Control cabinet Control panelStatus lamp Menu dial Power switch ON/OFFHow to use the control panel Symbol overviewMenu overview Menu levelsMenu Extra hot water Setting the heating, room sensor not installedSetting the heating, room sensor installed Set the heatingHot water sensor T3 TemperaturesFlow sensor T1 Outdoor sensor T2Overview Advanced menuHeat curve Flow temperatureOutdoor temperature Adjusting a single valueSet the heat curve Time control Set the desired room temperatureTime limited settings HysteresisHoliday Heating seasonHeating, maximum operating time at hot water requirement Hot water peak Hot water settingsRecurring increase in the hot water temperature Extra hot waterSetting the clock TimersDeactivate alarm buzzer Alarm logAccess level Return to factory settingsProtective covers MaintenanceUnscrew the protective covers Remove dirt and leavesSnow and ice Particle filterEvaporator Emergency operation What to do if a fault occursExample of an alarm Dimmed menu displayList of all warning windows All alarms and warning windowsList of all alarms Tripped low pressure switchSensor failure / short circuit Tripped high pressure switchT8 High flow temperature Faulty function in 4-way valveT6 High hot gas temperature Tripped motor cut-out compressor Low temperature in condenserPossible cause 3 Faulty heat carrier pump Possible cause 4 Compressor errorTripped motor cut-out fan Optima1000/1300 High temperature difference heat transfer fluidPossible cause 4 Faulty fan motor Possible cause 2 The hot water temperature is set too highAction Open the valves Technical information Factory settingsSound levels Technical informationSensor table Temperature ºC

600 - 1700 specifications

The Optima Company 600 - 1700 is a sophisticated product line designed to meet the demanding needs of modern industrial applications. Recognized for its efficiency and versatility, the Optima 600 - 1700 series has gained traction across various sectors, including manufacturing, chemical processing, and energy production.

At its core, the Optima 600 - 1700 combines cutting-edge technology with user-friendly features. One of the standout characteristics of this series is its advanced control system. The intuitive interface allows operators to easily configure settings, monitor performance, and receive real-time updates on system conditions. This feature not only enhances user experience but also maximizes operational efficiency by minimizing downtime.

A notable aspect of the Optima series is its modular design, which offers a high degree of customization. Businesses can choose from various configurations and components that best suit their specific operational needs. This adaptability means that the Optima 600 - 1700 can be scaled up or down, making it ideal for both small-scale operations and large production facilities.

The durability of the Optima 600 - 1700 is another key feature. Designed to withstand harsh industrial environments, the materials used in its construction ensure longevity and reliability. Manufacturers have prioritized robust engineering, resulting in a product that requires minimal maintenance while consistently delivering optimal performance.

Energy efficiency is a critical focus for the Optima Company, and the 600 - 1700 series exemplifies this commitment. The equipment is designed to minimize energy consumption without sacrificing functionality. This not only reduces operational costs for businesses but also aligns with global sustainability goals.

Further enhancing its capabilities, the Optima 600 - 1700 series incorporates smart technology features. With integrated IoT functionalities, clients can benefit from predictive maintenance, enabling them to anticipate potential issues before they escalate. This proactive approach to maintenance leads to increased uptime and can result in substantial cost savings over the lifespan of the equipment.

In summary, the Optima Company 600 - 1700 series stands out as a remarkable solution in the industrial equipment market. With its combination of advanced technology, customization options, durability, energy efficiency, and smart features, it meets the evolving demands of businesses while ensuring reliability and performance. Manufacturers and industrial operators looking for an advanced yet practical solution would do well to consider the Optima 600 - 1700 series as a key asset in their operational arsenal.