Advanced menu

Set the heat curve

1.Select Heat curve in the menu Heating system temperature. The current curve is shown here. The value 32.8 is the flow temperature at 0ºC.

2.Start by finding the value you wish to change. It can be V, H or some other value. To find the correct value, turn the dial clockwise or anti-clockwise. At the top of the display, various outdoor temperatures with corresponding flow values on the curve are shown, at the bottom, a dash can be seen that shows the position on the outdoor temperature axis. Continue turning the dial and you will eventually find the H value. Continue turning the dial even when you see a back arrow.

3.The most common adjustment is to increase the H value slightly to obtain more heating in cold weather. In the display you will see that the H value has been located and then marked by pressing the dial. The H value can now be changed by turning the dial. When you are happy with the H value, press the dial and select Save.

4.It may also be necessary to change a specific value on the curve, e.g. to increase the heating at temperatures around 0ºC. Turn the dial to find the value at 0ºC and press the dial to mark the value.

In the example to the right, the value at 0ºC has been changed to 36.8ºC, i.e. the flow temperature has been increased by four degrees. The dial has been pressed and Save has been marked. The changed curve is now saved by pressing the dial.

Recommended values: Increase by 4ºC at outdoor temperature of 0ºC and by 2ºC at outdoor temperature of +5ºC.

5.To exit the Heat curve function turn the dial until you see a back arrow. Press the dial.

Note

You should wait at least twenty-four hours when increasing or decreas- ing the heating before making a new adjustment. Only change one value at a time until you are happy with your temperature settings.

20

Image 20
Contents IVT Optima Page Page Innehåll For the user Important informationHeat pump collects heat from the outdoor air How a heat pump worksTechnology in and around the heat pump How a heat pump works Component parts of the heat pump IVT OptimaComponent parts of the heat pump Control unit Rego Automatic defrostingAdditional heat gives more output Hot water is given priority over heating waterControl unit’s operating modes Heat pump with electric cassetteHeat pump with electric boiler 290 A/W OptimaControl with an outdoor sensor Control with an outdoor sensor and a room sensor290 A/W Control cabinet Control panelStatus lamp Power switch ON/OFF How to use the control panelSymbol overview Menu dialMenu overview Menu levelsMenu Setting the heating, room sensor not installed Setting the heating, room sensor installedSet the heating Extra hot waterTemperatures Flow sensor T1Outdoor sensor T2 Hot water sensor T3Advanced menu OverviewFlow temperature Outdoor temperatureAdjusting a single value Heat curveSet the heat curve Set the desired room temperature Time limited settingsHysteresis Time controlHoliday Heating seasonHeating, maximum operating time at hot water requirement Hot water settings Recurring increase in the hot water temperatureExtra hot water Hot water peakTimers Setting the clockAlarm log Access levelReturn to factory settings Deactivate alarm buzzerMaintenance Unscrew the protective coversRemove dirt and leaves Protective coversSnow and ice Particle filterEvaporator What to do if a fault occurs Example of an alarmDimmed menu display Emergency operationAll alarms and warning windows List of all alarmsTripped low pressure switch List of all warning windowsTripped high pressure switch Sensor failure / short circuitT8 High flow temperature Faulty function in 4-way valveT6 High hot gas temperature Low temperature in condenser Possible cause 3 Faulty heat carrier pumpPossible cause 4 Compressor error Tripped motor cut-out compressorHigh temperature difference heat transfer fluid Possible cause 4 Faulty fan motorPossible cause 2 The hot water temperature is set too high Tripped motor cut-out fan Optima1000/1300Action Open the valves Factory settings Technical informationTechnical information Sound levelsTemperature ºC Sensor table

600 - 1700 specifications

The Optima Company 600 - 1700 is a sophisticated product line designed to meet the demanding needs of modern industrial applications. Recognized for its efficiency and versatility, the Optima 600 - 1700 series has gained traction across various sectors, including manufacturing, chemical processing, and energy production.

At its core, the Optima 600 - 1700 combines cutting-edge technology with user-friendly features. One of the standout characteristics of this series is its advanced control system. The intuitive interface allows operators to easily configure settings, monitor performance, and receive real-time updates on system conditions. This feature not only enhances user experience but also maximizes operational efficiency by minimizing downtime.

A notable aspect of the Optima series is its modular design, which offers a high degree of customization. Businesses can choose from various configurations and components that best suit their specific operational needs. This adaptability means that the Optima 600 - 1700 can be scaled up or down, making it ideal for both small-scale operations and large production facilities.

The durability of the Optima 600 - 1700 is another key feature. Designed to withstand harsh industrial environments, the materials used in its construction ensure longevity and reliability. Manufacturers have prioritized robust engineering, resulting in a product that requires minimal maintenance while consistently delivering optimal performance.

Energy efficiency is a critical focus for the Optima Company, and the 600 - 1700 series exemplifies this commitment. The equipment is designed to minimize energy consumption without sacrificing functionality. This not only reduces operational costs for businesses but also aligns with global sustainability goals.

Further enhancing its capabilities, the Optima 600 - 1700 series incorporates smart technology features. With integrated IoT functionalities, clients can benefit from predictive maintenance, enabling them to anticipate potential issues before they escalate. This proactive approach to maintenance leads to increased uptime and can result in substantial cost savings over the lifespan of the equipment.

In summary, the Optima Company 600 - 1700 series stands out as a remarkable solution in the industrial equipment market. With its combination of advanced technology, customization options, durability, energy efficiency, and smart features, it meets the evolving demands of businesses while ensuring reliability and performance. Manufacturers and industrial operators looking for an advanced yet practical solution would do well to consider the Optima 600 - 1700 series as a key asset in their operational arsenal.