Optima Company 600 - 1700 Maintenance, Unscrew the protective covers, Remove dirt and leaves

Page 26

Maintenance

Maintenance

Your heat pump requires a minimum of maintenance, however, we still recommend some servicing to get optimal performance from your heat pump. Check the following items a few times during the first year. You should then check them once or twice a year:

Remove dirt and leaves

Particle filter

Protective covers

Evaporator

Warning

For reasons of safety the main power supply must be disconnected before working on the heat pump.

Only an accredited refrigeration company is permitted to work on the refrigerant circuit.

Unscrew the protective covers

You must unscrew the outer covers to access some of the maintenance areas.

To remove the covers from the heat pump:

1.Turn the screws on top of the heat pump a few turns.

2.Rest the cover against your body.

3.Lift the cover upwards to release the lower edge.

Remove dirt and leaves

Over time leaves and other dirt can enter the heat pump. You can easily remove any dirt through the inspection hatch on the side of the heat pump. Unscrew the left side plate (seen from the front) and use a brush to remove the dirt. Check that the drainage hole is not blocked. Exercise care around the thin aluminium fins. They are fragile and you can injure yourself if careless. The plate and drainage hole can be rinsed with water if necessary.

Protective covers

Over time dust and other dirt will collect on the heat pump. You should wipe the outside with a damp cloth if necessary. Scratches and damage to the outer plates should be touched up using an anti corrosive rust-inhibitor. Use normal car polish to protect the paint.

Overheat protection electric cassette

The button for resetting the electric cassette’s overheat protection is in the electric cassette. This is a protection that should normally not be deployed. If, however, this does deploy, reset it by pressing in the button with some force. If the overheat protection device deploys frequently, call a service engineer to establish the cause.

Overheat protection is also available for the electric element in 290 A/W, see the user guide for 290 A/W.

26

Remove the covers by loosening the

screws on top of the heat pump.

Optima 600-1100

Inspection hatch

Drainage hole

Optima 1400-1700

Inspection hatch

Drainage hole

Electric cassette

Button to reset overheat protection

Image 26
Contents IVT Optima Page Page Innehåll For the user Important informationHeat pump collects heat from the outdoor air How a heat pump worksTechnology in and around the heat pump How a heat pump works Component parts of the heat pump IVT OptimaComponent parts of the heat pump Additional heat gives more output Control unit RegoAutomatic defrosting Hot water is given priority over heating waterHeat pump with electric boiler 290 A/W Control unit’s operating modesHeat pump with electric cassette OptimaControl with an outdoor sensor Control with an outdoor sensor and a room sensor290 A/W Control cabinet Control panelStatus lamp Symbol overview Power switch ON/OFFHow to use the control panel Menu dialMenu overview Menu levelsMenu Set the heating Setting the heating, room sensor not installedSetting the heating, room sensor installed Extra hot waterOutdoor sensor T2 TemperaturesFlow sensor T1 Hot water sensor T3Advanced menu OverviewAdjusting a single value Flow temperatureOutdoor temperature Heat curveSet the heat curve Hysteresis Set the desired room temperatureTime limited settings Time controlHoliday Heating seasonHeating, maximum operating time at hot water requirement Extra hot water Hot water settingsRecurring increase in the hot water temperature Hot water peakTimers Setting the clockReturn to factory settings Alarm logAccess level Deactivate alarm buzzerRemove dirt and leaves MaintenanceUnscrew the protective covers Protective coversSnow and ice Particle filterEvaporator Dimmed menu display What to do if a fault occursExample of an alarm Emergency operationTripped low pressure switch All alarms and warning windowsList of all alarms List of all warning windowsTripped high pressure switch Sensor failure / short circuitT8 High flow temperature Faulty function in 4-way valveT6 High hot gas temperature Possible cause 4 Compressor error Low temperature in condenserPossible cause 3 Faulty heat carrier pump Tripped motor cut-out compressorPossible cause 2 The hot water temperature is set too high High temperature difference heat transfer fluidPossible cause 4 Faulty fan motor Tripped motor cut-out fan Optima1000/1300Action Open the valves Factory settings Technical informationTechnical information Sound levelsTemperature ºC Sensor table

600 - 1700 specifications

The Optima Company 600 - 1700 is a sophisticated product line designed to meet the demanding needs of modern industrial applications. Recognized for its efficiency and versatility, the Optima 600 - 1700 series has gained traction across various sectors, including manufacturing, chemical processing, and energy production.

At its core, the Optima 600 - 1700 combines cutting-edge technology with user-friendly features. One of the standout characteristics of this series is its advanced control system. The intuitive interface allows operators to easily configure settings, monitor performance, and receive real-time updates on system conditions. This feature not only enhances user experience but also maximizes operational efficiency by minimizing downtime.

A notable aspect of the Optima series is its modular design, which offers a high degree of customization. Businesses can choose from various configurations and components that best suit their specific operational needs. This adaptability means that the Optima 600 - 1700 can be scaled up or down, making it ideal for both small-scale operations and large production facilities.

The durability of the Optima 600 - 1700 is another key feature. Designed to withstand harsh industrial environments, the materials used in its construction ensure longevity and reliability. Manufacturers have prioritized robust engineering, resulting in a product that requires minimal maintenance while consistently delivering optimal performance.

Energy efficiency is a critical focus for the Optima Company, and the 600 - 1700 series exemplifies this commitment. The equipment is designed to minimize energy consumption without sacrificing functionality. This not only reduces operational costs for businesses but also aligns with global sustainability goals.

Further enhancing its capabilities, the Optima 600 - 1700 series incorporates smart technology features. With integrated IoT functionalities, clients can benefit from predictive maintenance, enabling them to anticipate potential issues before they escalate. This proactive approach to maintenance leads to increased uptime and can result in substantial cost savings over the lifespan of the equipment.

In summary, the Optima Company 600 - 1700 series stands out as a remarkable solution in the industrial equipment market. With its combination of advanced technology, customization options, durability, energy efficiency, and smart features, it meets the evolving demands of businesses while ensuring reliability and performance. Manufacturers and industrial operators looking for an advanced yet practical solution would do well to consider the Optima 600 - 1700 series as a key asset in their operational arsenal.