ing Gas Connections, pages 17 and 18)

TROUBLESHOOTING

29

TROUBLESHOOTING

Continued

Manual background WARNING: If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating fireplace where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors. These odors will disappear over time.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Fireplace produces a clicking/ticking noise just after burners are lit or shut off

1.Metal expanding while heating or con- tracting while cooling

1.This is common with most fireplaces. If noise is excessive, contact qualified ser- vice person

Fireplace produces unwanted odors

1.

Fireplace burning vapors from paint, hair

 

 

spray, glues, cleaners, chemicals, new

 

 

carpet, etc. (see IMPORTANT statement

 

 

above)

 

2.

Gas leak. See Warning statement

 

 

above

1.Open window and ventilate room. Stop using odor causing products while fire- place is running

2.Locate and correct all leaks (see Check- ing Gas Connections, pages 17 and 18)

Fireplace shuts off in use (ODS operates)

1.

Not enough fresh air is available

1.

Open window and/or door for ventilation

 

2.

Low line pressure

2.

Contact local gas company

 

3.

ODS/pilot is partially clogged

3.

Clean ODS/pilot (see Cleaning and

 

 

 

 

Maintenance, page 26)

 

 

 

 

 

Gas odor even when wall switch and remote

1.

Gas leak. See Warning statement

1.

Locate and correct all leaks (see Check-

control buttons and switches are in OFF

 

above

 

ing Gas Connections, pages 17 and 18)

position

2.

Control valve defective

2.

Replace control valve

 

 

 

 

 

Gas odor during combustion

1.

Foreign matter between control valve

1.

Take apart gas tubing and remove for-

 

 

and burner

 

eign matter

 

2.

Gas leak. See Warning statement

2.

Locate and correct all leaks (see Check-

 

 

above

 

ing Gas Connections, pages 17 and 18)

 

 

 

 

 

Dark residue on logs or inside of fireplace Note: After removng all causes of residue deposits, completely clean fireplace and appli- ances of all residue before reusing appliance.

1.Improper log placement

2.Drafts or other air currents affecting flame pattern

3.Air holes at burner inlet blocked

4.Burner flame holes blocked

1.Properly locate logs (see Installing Logs, pages 21 and 22)

2.Eliminate source of drafts around heater

3.Clean out air holes at burner inlet. Peri- odically repeat as needed

4.Remove blockage

White powder residue forming within burner box or on adjacent walls or furniture

1.When heated, vapors from furniture pol- ish, wax, carpet cleaners, etc. may turn into white powder residue

1.Turn heater off when using furniture polish, wax, carpet cleaners, or similar products

Manual backgroundFor moreManual backgroundManual backgroundManual backgroundvisit www.Manual backgroundManual backgroundManual background.comManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background

111245-01A

Page 29
Image 29
Desa CGEFP33NRB, CGEFP33PRB Troubleshooting, Continued, Observed Problem, Possible Cause, Remedy, Maintenance, page