ELECTRICAL CONNECTIONS FOR POWER CORD

INSTALLATION

Removing Fireplace Screen And Floor Assembly (Cont.) Electrical Connections for Power Cord Relocating Wall Switch Assembly

9

INSTALLATION

Continued

Flexible Gas Line

Screws

Fireplace Floor

Assembly

Figure 6 - Removing Fireplace Floor Assembly

ELECTRICAL CONNECTIONS FOR POWER CORD

This fireplace operates on 120 VAC, 60 Hz power. An electrical power cord is supplied with this unit.

For Mantel Installation

1.Determine from which side of the fireplace the power cord will exit. Locate the 1.5" diameter hole near the center of floor sup- port bracket on appropriate side of lower cavity (see Figure 7).

2.Locate power cord. Remove wire tie or tape holding plug end of power cord.

3.Power cord has 2 plastic hole bushings threaded onto it. Route cord's 3-prong plug through the 1.5" diameter hole in appro- priate floor support bracket.

4.Push first plastic bushing completely through hole. Squeeze bushing as needed to do this.

5.Install the second plastic bushing into the hole in the floor sup- port bracket by snapping into place.

6.Route the 3-prong plug through the 1.5" hole in fireplace outer casing.

7.Install the first plastic bushing into this hole by snapping into place.

8.After you have connected to gas supply and checked your gas connections (see pages 15 through 18), plug power cord into any convenient 3-prong grounded wall receptacle near fireplace.

For Recessed Installation

If an outlet is not installed in fireplace, install model GA3555 - Outlet Kit with Cover. This kit will supply a convenient 3-prong grounded electrical outlet for power. Refer to installation manual provided with this optional accessory for instructions on wiring. Note: A qualified installer must make all electrical connections.

Hole in Floor

Hole in Outer

Support Bracket

Casing

Bushings For Mantel Installation

For Recessed InstallationRELOCATING WALL SWITCH ASSEMBLYPower Cord

Figure 7 - Routing Power Cord

RELOCATING WALL SWITCH ASSEMBLY

Note: The decorative wall switch plate supplied is white. The wall switch plate may be painted to match your decor.

The push-button switch and decorative wall plate assembly sup- plied with your fireplace is pre-mounted at the factory in the lower cavity of the fireplace. You may relocate this wall switch assembly to a more convenient location such as the side of your mantel or directly onto the wall near the fireplace. To mount the wall switch assembly, you must first cut openings in the mantel or wall where the switch will be located.

Note: If you choose to relocate the wall switch assembly, do so before final installation into a mantel or recessing into a wall. If you are installing an optional blower accessory, install it at the same time you relocate the wall switch assembly.

Manual background CAUTION: The wall switch assembly must never be mounted directly above the fireplace where heat may damage it. If you relocate wall switch assembly from lower fireplace cavity, it must be mounted either on side wall of mantel or on wall to side of fireplace.

For Recessed Installation

If fireplace is to be recessed into a wall (see Built-In Fireplace Installation, pages 19 and 20), we recommend mounting wall switch assembly to left side of fireplace. The wall switch assembly should be mounted approximately 12" from left edge of fireplace, and less than 60" from the floor. IMPORTANT: Do not locate wall switch assembly directly in front of wall stud - there must be room behind wall board for wires from switch. If you choose to locate wall switch assembly to right side of fireplace, the length of the cord restricts you to less than 6" from right edge of fireplace and less than 48" from floor.

Manual backgroundFor moreManual backgroundManual backgroundManual backgroundvisit www.Manual backgroundManual backgroundManual background.comManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background